Plasma column position measurements using magnetic diagnostics in ADITYA-U tokamak

被引:3
|
作者
Aich S. [1 ,5 ]
Kumar R. [5 ]
Macwan T.M. [1 ,5 ]
Kumavat D. [1 ,5 ]
Jha S. [5 ]
Tanna R.L. [2 ,5 ]
Sathyanarayana K. [5 ]
Ghosh J. [1 ,5 ]
Jadeja K.A. [3 ,5 ]
Patel K. [5 ]
Patel S. [4 ]
Ranjan V. [1 ,5 ]
Kalal M. [5 ]
Varia D. [5 ]
Sadharkiya D. [5 ]
Raju D. [1 ,5 ]
Chattopadhyay P.K. [1 ,5 ]
Gupta C.N. [5 ]
Saxena Y.C. [5 ]
机构
[1] Homi Bhabha National Institute Anushaktinagar, Maharashtra, Mumbai
[2] Institute of Science, Nirma University, Gujarat, Ahmedabad
[3] Department of Physics, Saurashtra University, Gujarat, Rajkot
[4] Pandit Deendayal Petroleum University, Raisan, Gujarat, Gandhinagar
[5] Institute for Plasma Research, Gujarat, Gandhinagar
来源
Plasma Research Express | 2021年 / 3卷 / 03期
关键词
Flux loop; Magnetic pick-up probe; Mirnov coil; Sine-Cosine coil;
D O I
10.1088/2516-1067/ac2731
中图分类号
学科分类号
摘要
Due to several forces acting on the plasma column in a tokamak, the plasma column tends to move horizontally and/or vertically leading to many adverse events including termination of plasma. Precise measurement of plasma column position throughout the discharge with good temporal resolution in the real time is hence necessary in order to restrict the column movement using the stabilizing equilibrium magnetic fields. The plasma column position is measured by several magnetic diagnostics such as magnetic pick-up probe, Mirnov coil, Sine-Cosine coil along with flux loops in ADITYA Upgrade tokamak (ADITYA-U). In spite of the simplicity of the measurement principle of these probes as well as of their construction, obtaining the position of the plasma column is not very straightforward. The diversity of all these magnetic diagnostics in terms of their structures, installation location, mounting scenario etc leads to improper position estimations as these probes are being affected differently by the unwanted magnetic pick-ups. These unwanted pickups, especially those arising from vessel eddies, are successfully removed by introducing a scaling method for all the above-mentioned position probes in ADITYA-U based on the in situ calibration of these probes. The correction factors are deduced by estimating the known positions of a central current carrying conductor correctly using the probe measurements during the in situ calibration. These correction factors are used for estimating the plasma column position in the tokamak experiment along with proper nullification of magnetic fields arising from other magnets during tokamak operation. The plasma column position estimation from different magnetic probes are compared with each other and also with those estimated from diagnostics other than the magnetic ones. © 2021 IOP Publishing Ltd
引用
收藏
相关论文
共 50 条
  • [31] Real-time feedback control system for ADITYA-U horizontal plasma position stabilisation
    Kumar, Rohit
    Gautam, Pramila
    Gupta, Shivam
    Tanna, R. L.
    Edappala, Praveenlal
    Shah, Minsha
    Raulji, Vismay
    Jadeja, K. A.
    Patel, K. M.
    Macwan, Tanmay
    Manchanda, Ranjana
    Chowdhuri, M. B.
    Yadava, Nandini
    Shah, Kunal
    Makwana, M. N.
    Balakrishnan, V
    Gupta, C. N.
    Aich, Suman
    Kumawat, Devilal
    Raj, Harshita
    Sathyanarayana, K.
    Ghosh, Joydeep
    Rajpal, Rachna
    Chattopadhyay, P. K.
    Saxena, Y. C.
    FUSION ENGINEERING AND DESIGN, 2021, 165 (165)
  • [32] Observations of visible argon line emissions and its spatial profile from Aditya-U tokamak plasma
    Shah, K.
    Ghosh, J.
    Shukla, G.
    Chowdhuri, M. B.
    Manchanda, R.
    Yadava, N.
    Ramaiya, N.
    Jadeja, K. A.
    Patel, K. M.
    Tanna, R. L.
    Mayya, K. B. K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (05):
  • [33] Controlling the rotation of drift tearing modes by biased electrode in ADITYA-U tokamak
    Macwan, Tanmay
    Singh, Kaushlender
    Dolui, Suman
    Kumar, Ankit
    Raj, Harshita
    Gautam, Pramila
    Edappala, Praveenlal
    Ghosh, J.
    Tanna, R. L.
    Kumar, Rohit
    Jadeja, K. A.
    Patel, K. M.
    Aich, Suman
    Kumar, Sameer
    Raju, D.
    Chattopadhyay, P. K.
    Sen, A.
    Saxena, Y. C.
    Pal, R.
    PHYSICS OF PLASMAS, 2021, 28 (11)
  • [34] Commissioning of Electron Cyclotron Resonance Heating (ECRH) system on tokamak Aditya-U
    Shukla, Braj K.
    Patel, Jatin
    Mistry, Hardik
    Patel, Harshida
    Purohit, Dharmesh
    Parmar, K. G.
    Babu, Rajan
    Ghosh, Joydeep
    Tanna, Rakesh
    Jadeja, Kumarpalsinh
    Patel, Kaushal
    Makwana, Moti
    Gupta, C. N.
    Kushwah, Mahesh
    FUSION ENGINEERING AND DESIGN, 2019, 146 : 2083 - 2086
  • [35] Investigation of impulse voltage test of ohmic coil system in ADITYA-U tokamak
    Kumar, Rohit
    Raj, Harshita
    Tanna, R. L.
    Macwan, Tanmay
    Aich, S.
    Ghosh, J.
    FUSION ENGINEERING AND DESIGN, 2024, 200
  • [36] Lithium wall conditioning techniques in ADITYA-U tokamak for impurity and fuel control
    Jadeja, K. A.
    Ghosh, J.
    Yadava, Nandini
    Patel, K. M.
    Patel, Kiran
    Tanna, R. L.
    Manchanda, R.
    Chowdhuri, M. B.
    Raval, J., V
    Nagora, U. C.
    Arambhadiya, B. G.
    Macwan, Tanmay
    Singh, K.
    Dolui, S.
    Shah, Minsha
    Patel, Sharvil
    Ramaiya, N.
    Shah, Kajal
    Shukla, B. K.
    Aich, Suman
    Kumar, Rohit
    Panchal, V. K.
    Kumar, Manoj
    Atrey, P. K.
    Pathak, S. K.
    Rajpal, Rachana
    Assudani, Kumudni
    Gopalakrishna, M., V
    Kumawat, Devilal
    Makwana, M. N.
    Shah, K. S.
    Gupta, Shivam
    Gupta, C. N.
    Balakrishnan, V
    Chattopadhyay, P. K.
    Kataria, B. R.
    NUCLEAR FUSION, 2022, 62 (01)
  • [37] Initial results from near-infrared spectroscopy on ADITYA-U tokamak
    Ramaiya, N.
    Manchanda, R.
    Chowdhuri, M. B.
    Yadava, N.
    Dey, R.
    Kumar, A.
    Shah, K.
    Patel, S.
    Jadeja, K. A.
    Patel, K. M.
    Kumar, R.
    Aich, S.
    Pathak, S. K.
    Tanna, R. L.
    Ghosh, J.
    ADITYA-U team
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11):
  • [38] Recovery of electromagnetic coils insulation under varying conditions in ADITYA-U tokamak
    Kumar, Rohit
    Ghosh, J.
    Tanna, R. L.
    Aich, Suman
    Macwan, Tanmay
    FUSION ENGINEERING AND DESIGN, 2023, 189
  • [39] Upgraded space and time resolved visible spectroscopic diagnostic on ADITYA-U tokamak
    Modi, Dipexa
    Chowdhuri, M. B.
    Yadava, N.
    Kumar, A.
    Ramaiya, N.
    Gauttam, A.
    Rajvanshi, U.
    Rathor, M.
    Patel, S.
    Sheeba, R. R.
    Mayya, K. B. K.
    Pathak, S. K.
    Ghosh, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (12):
  • [40] Design of tangential x-ray crystal spectrometer for Aditya-U tokamak
    Shah, K.
    Chowdhuri, M. B.
    Shukla, G.
    Manchanda, R.
    Mayya, K. B. K.
    Jadeja, K. A.
    Pablant, N. A.
    Ghosh, J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):