Evaluation technology for the operational status of overhead lines based on a health index

被引:0
作者
Gao F. [1 ]
Liu Y. [2 ]
Jia P. [1 ]
Yang Y. [1 ]
机构
[1] China Electric Power Research Institute Co., Ltd., Beijing
[2] School of Automation Science and Electrical Engineering, Beihang University, Beijing
来源
Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control | 2024年 / 52卷 / 12期
基金
中国国家自然科学基金;
关键词
health index; overhead lines; status evaluation;
D O I
10.19783/j.cnki.pspc.231186
中图分类号
学科分类号
摘要
There are problems in the evaluation of the operational status of overhead lines. Thus a comprehensive evaluation method based on a health index is proposed. The method combines the operational characteristics of overhead lines. It involves comprehensive consideration of the line itself and the external factors such as weather and environment. The method systematically considers the key factors and their influencing coefficients on the health status of the line. Taking into account the importance of different influencing factors and adopting a combination of qualitative and quantitative methods, a calculation method for the line health index based on a combination of the analytic hierarchy process, the distance between good and poor solutions, and an expert discussion method is proposed. Using this method, on-site verification is conducted on the actual operational status of a 110 kV overhead line in Nanjing. The results demonstrate the effectiveness of the proposed method. The method proposed in this paper is not only applicable to the assessment of the health status of overhead lines, but also provides a reference for the health status assessment of other power equipment. © 2024 Power System Protection and Control Press. All rights reserved.
引用
收藏
页码:167 / 176
页数:9
相关论文
共 27 条
  • [1] MA Guoming, WANG Sihan, QIN Weiqi, Et al., Research and prospect in optical fiber sensing of transmission line operating conditions, High Voltage Engineering, 48, 8, pp. 3032-3047, (2022)
  • [2] SONG Yunhai, ZHANG Hourong, ZHENG Wenjian, Et al., New type of non-contact current sensor for monitoring the operation state of the DC overhead transmission line, Electrical Automation, 42, 4, pp. 89-91, (2020)
  • [3] ZHAN Yabo, XU Qian, LI Jun, Et al., Periodic low-power communication technology scheme for large-scale transmission line condition monitoring sensor network, Telecommunications Science, 39, 2, pp. 83-91, (2023)
  • [4] ZUO Pengqi, Research on key technology of transmission line condition monitoring based on wireless sensor network, (2022)
  • [5] YANG Lei, Research on synchronous measurement unit in transmission line condition system, (2016)
  • [6] YANG Fang, TANG Xiaoliang, YIN Wenkuo, Et al., Analysis of transmission line wind vibration monitoring based on a multi parameter distributed optical fiber sensor, Power System Protection and Control, 50, 11, pp. 169-177, (2022)
  • [7] ZHANG Yongqian, Research and application of online monitoring system of running state of high voltage transmission line, (2017)
  • [8] ZHAO Wenbin, LI Huixing, FEI Zhengming, Et al., Construction of transmission line state detection system based on smart grid requirements, East China Electric Power, 38, 8, pp. 1212-1216, (2010)
  • [9] WANG Kai, CAI Wei, DENG Yurong, Et al., Application and management information platform for transmission line monitoring system, High Voltage Engineering, 38, 5, pp. 1274-1280, (2012)
  • [10] WANG Haiyang, GONG Weinan, ZHAO Zhongqiang, Et al., Research on state monitoring of power transmission lines based on the internet of things, Electrotechnical Application, 39, 9, pp. 76-78, (2020)