Performance research on high temperature CO2 heat pump with supercritical enhanced gas injection

被引:0
|
作者
Wu, Mengxia [1 ,2 ,3 ,4 ]
Wang, Hanzhi [2 ,3 ,4 ]
Li, Shuaiqi [2 ,3 ,4 ]
Song, Wenji [2 ,3 ,4 ]
Feng, Ziping [1 ,2 ,3 ,4 ]
机构
[1] School of Engineering Science, University of Science and Technology of China, Hefei,Anhui,230026, China
[2] Guangzhou Institute of Energy Conversion, Chinese Academy of Sciences, Guangzhou,Guangdong,510640, China
[3] CAS Key Laboratory of Renewable Energy, Guangzhou,Guangdong,510640, China
[4] Guangdong Provincial Key Laboratory of New and Renewable Energy Research and Development, Guangzhou,Guangdong,510640, China
关键词
Carbon dioxide - Compressibility of gases - Cooling systems - Gas compressors - Heat pump systems - Pumps;
D O I
10.16085/j.issn.1000-6613.2019-1404
中图分类号
学科分类号
摘要
A novel high temperature CO2 heat pump cycle with supercritical enhanced gas injection was proposed to significantly improve heating performance under high temperature hydronic heating conditions. The numerical model of the high temperature CO2 heat pump system with supercritical gas injection was established, and the performance of the system was analyzed by EES (engineering equation solver) software. The influence of parameters such as evaporation temperature, middle pressure of compressor, gas cooler pressure, etc. on system performance at the high gas cooler outlet temperature was mainly studied. The results indicated that COP of 3.0 can be reached when the gas cooler outlet temperature was as high as 60℃. In comparison to common vapor injection system, the COP improved distinctly. As compared to conventional system without gas injection, the COP increased by 14.8%, 21.2%, 29.2% respectively with gas injection ratio of 0.3, 0.4, 0.5 at the gas cooler outlet temperature of 60℃. The influence of middle pressure and gas cooler pressure on COP have the same variation trend while the effect of gas cooler pressure is more significant. Besides, there exist an optimal gas cooler pressure and middle pressure. The optimal gas cooler pressure and middle pressure are 13.5MPa and 8.5MPa, respectively, when the gas cooler outlet temperature is 60℃ and the gas injection ratio is 0.4. © 2020, Chemical Industry Press. All right reserved.
引用
收藏
页码:1667 / 1673
相关论文
共 50 条
  • [31] Performance optimization of CO2 heat pump water heater
    Nawaz, Kashif
    Shen, Bo
    Elatar, Ahmed
    Baxter, Van
    Abdelaziz, Omar
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2018, 85 : 213 - 228
  • [32] The Heating Performance of a CO2 Heat Pump Water Heater
    Baek, Changhyun
    Lee, Eungchan
    Kang, Hoon
    Kim, Yongchan
    Cho, Honghyun
    Cho, Sungwook
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 258 - 263
  • [33] Numerical investigation on the heating performance of a transcritical CO2 vapor-injection heat pump system
    Peng, Xu
    Wang, Dingbiao
    Wang, Guanghui
    Yang, Yushen
    Xiang, Sa
    APPLIED THERMAL ENGINEERING, 2020, 166 (166)
  • [34] Effects of vapor injection techniques on the heating performance of a CO2 heat pump at low ambient temperatures
    Baek, Changhyun
    Heo, Jaehyeok
    Jung, Jongho
    Lee, Eungchan
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 43 : 26 - 35
  • [35] Performance of a CO2 Water to Water Heat Pump with Less Charge: Inlet Temperature Effects
    Maina, Paul
    Huan, Zhongjie
    PROCEEDINGS OF THE 13TH CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY, 2015, : 239 - 244
  • [36] Research progress and prospect of the integrated supercritical CO2 enhanced shale gas recovery and geological sequestration
    Lu Y.
    Zhou J.
    Xian X.
    Tang J.
    Zhou L.
    Jiang Y.-D.
    Xia B.
    Wang X.
    Kang Y.
    Natural Gas Industry, 2021, 41 (06) : 60 - 73
  • [37] Performance research on a CO2 heat pump system with novel control strategy in electric vehicle
    Teng, Haixu
    Wang, Jun
    Wang, Yuncong
    Song, Zhanzhuo
    Liu, Dong
    Liu, Zhikun
    Xue, Xiaoye
    Chang, Wei
    Li, Ming
    APPLIED THERMAL ENGINEERING, 2025, 259
  • [38] High temperature corrosion of cast heat resisting steels in CO + CO2 gas mixtures
    Xu, Nan
    Monceau, Daniel
    Young, David
    Furtado, Jader
    CORROSION SCIENCE, 2008, 50 (08) : 2398 - 2406
  • [39] High temperature electrochemical heat pump using water gas shift reaction -: Electrolytic reduction of CO2 in molten carbonate
    Ishihara, A
    Fujimori, T
    Motohira, N
    Ota, K
    Kamiya, N
    MOLTEN SALTS XII, PROCEEDINGS, 2000, 99 (41): : 744 - 751
  • [40] Evaluation of recycle gas injection on CO2 enhanced oil recovery and associated storage performance
    Jin, Lu
    Pekot, Lawrence J.
    Hawthorne, Steven B.
    Salako, Olarinre
    Peterson, Kyle J.
    Bosshart, Nicholas W.
    Jiang, Tao
    Hamling, John A.
    Gorecki, Charles D.
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 75 : 151 - 161