STUDIES ON COOLING OPERATION OF TABS COMBINED WITH FLOOR SUPPLY DISPLACEMENT AIR CONDITIONING SYSTEM

被引:0
|
作者
Akihiro K. [1 ]
Shinichiro O. [2 ]
Hisashi H. [3 ]
Masato N. [2 ]
Masayoshi Y. [2 ]
机构
[1] Institute of Technology, Shimizu Corporation
[2] Design Dept., Shimizu Corporation
[3] Group Leader, Institute of Technology, Shimizu Corporation, Dr.Eng.
关键词
Field survey; Floor supply; Load leveling; TABS; Water thermal storage tank;
D O I
10.3130/aijt.30.832
中图分类号
学科分类号
摘要
The cooling operational performance of TABS combined with floor supply displacement air conditioning system adopted in the Tohoku Branch of S company was investigated. The purpose of this research was to evaluate four control methods and clarify their energy consumption efficiency and load leveling effects. By operating with the proposed control method, the peak amount of received power was reduced by approximately 10%, confirming high energy consumption efficiency. Additionally, a thermal environment was created in the office as planned, with small temperature differences. © 2024 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:832 / 837
页数:5
相关论文
共 50 条
  • [1] STUDIES ON WINTER OPERATION EFFICIENCY OF TABS AND FLOOR BLOW AIR CONDITIONING SYSTEM USING GROUNDWATER AS A HEAT SOURCE/SINK
    Koike R.
    Tarumi H.
    Shinmura S.
    Amada Y.
    Miyamura Y.
    Hasebe H.
    Yamamoto M.
    AIJ Journal of Technology and Design, 2023, 29 (71) : 275 - 279
  • [2] Analysis of feasibility of floor radiant cooling system combined with displacement ventilation
    Li, DY
    Ren, YL
    Wang, ZJ
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 634 - 637
  • [3] Simulation and analysis of combined evaporative cooling and cooling ceiling air-conditioning system
    Huang, Xiang
    Li, Yinming
    Wu, Junmei
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (SUPPL.): : 205 - 208
  • [4] Experimental Study on Performance Comparison Between Heavy and Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation Air Conditioning System
    Zhang, Dongliang
    Cai, Ning
    Rui, Yingxiang
    Tang, Hu
    Liu, Minghui
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 475 - 483
  • [5] Development of new heating ventilating and air conditioning system of operation floor in reactor building
    Takamori, Kazuhide
    Naito, Masanori
    Hanamura, Ikuo
    Matsumura, Kazuhiro
    Nippon Genshiryoku Gakkaishi/Journal of the Atomic Energy Society of Japan, 1988, 30 (02): : 155 - 164
  • [6] Energy consumption analysis of the combined evaporative cooling and cooling ceiling air-conditioning system
    Huang, Xiang
    Li, Yinming
    Wu, Junmei
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 201 - +
  • [7] Floor heating and cooling combined with displacement ventilation: Possibilities and limitations
    Causone, Francesco
    Baldin, Fabio
    Olesen, Bjarne W.
    Corgnati, Stefano P.
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2338 - 2352
  • [8] Influence of air-conditioning intermittent operation on the cooling in
    Meng, Xi
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 58
  • [9] Effect of Air Conditioning Position on Thermal Comfort in the Floor Air Conditioning System
    Sabtalistia, Y. A.
    Ekasiwi, S. N. N.
    Iskandriawan, B.
    ADVANCES IN APPLIED MECHANICS AND MATERIALS, 2014, 493 : 74 - +
  • [10] Decoupling Control on Air-conditioning System with Combined Radiant Cooling and Independent Fresh air
    Tan, Yongguang
    Yue, Shihong
    2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 337 - +