Analysis of signal waveform from a midsize liquid argon detector

被引:0
|
作者
Zhao, K. K. [1 ,2 ]
Guan, M. Y. [2 ,3 ]
Liu, J. C. [2 ,3 ]
Yang, C. G. [2 ,3 ]
Lin, S. T. [1 ]
机构
[1] Sichuan Univ, Coll Phys, Chengdu 610065, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
来源
JOURNAL OF INSTRUMENTATION | 2023年 / 18卷 / 09期
关键词
Noble liquid detectors (scintillation; ionization; double-phase); Scintillators; scintillation and light emission processes (solid; gas and liquid scintillators); Cryogenic detectors; Photon detectors for UV; visible and IR photons (vacuum); KRYPTON; LUMINESCENCE; STATES;
D O I
10.1088/1748-0221/18/09/T09006
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The midsize single-phase liquid argon prototype detector, operating at the surface laboratory, is designed to measure scintillation light emitted by the liquid argon (LAr). The detector employs 42 8-inch photomultiplier tubes (PMT) to collect the light. By analyzing the waveform of the signal, important detector characteristics such as the slow decay time constant that characterizes the purity of the liquid argon can be obtained. To describe the signal waveform, a model, which takes into account the liquid argon emission decay times together with the TPB re-emission process as well as the signal reflection effects, is used. The TPB re-emission process is introduced using a three-exponential time structure. Additionally, experimental results provide comprehensive validation for a post-peak hump structure, which is attributed to signal reflection.
引用
收藏
页数:10
相关论文
共 44 条
  • [41] RETRACTED: Analysis of the dynamics of laser induced plume propagation from liquid matrix using fast photography (Retracted article. See OCT, 2019)
    Fan, Xing
    Xiao, Jian
    Hu, Guang-Zhou
    Zhao, Yun-Peng
    Kang, Shi-Gang
    Lu, Jin-Li
    Fan, Hong-Ru
    CHEMICAL PAPERS, 2016, 70 (06) : 848 - 855
  • [42] Analysis of mexicanolide- and phragmalin-type limonoids from Heynea trijuga using high-performance liquid chromatography/electrospray tandem mass spectrometry
    Yang, Wei
    Fang, Dong-Mei
    He, Hong-Ping
    Hao, Xiao-Jiang
    Wu, Zhi-Jun
    Zhang, Guo-Lin
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (11) : 1203 - 1212
  • [43] Separation of Glycolipids/Sphingolipids from Glycerophospholipids on TiO2 Coating in Aprotic Solvent for Rapid Comprehensive Lipidomic Analysis with Liquid Microjunction Surface Sampling-Mass Spectrometry
    Huang, Zehui
    Wu, Qian
    Lu, Hongmei
    Wang, Yang
    Zhang, Zhimin
    ANALYTICAL CHEMISTRY, 2020, 92 (16) : 11250 - 11259
  • [44] Analysis of the chemical components of pomelo peels (Citrus grandis [L.] Osbeck) from different cultivars by using supercritical CO2 fluid extraction and ultra-high-performance liquid chromatography-tandem mass spectrometry
    Su, Boqing
    Tian, Jingyuan
    Liu, Mengshi
    Wang, Kanghui
    Yang, Wanling
    Ning, Jinrong
    Li, Yongmei
    Zheng, Guodong
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (15) : 3031 - 3042