Thermal performance analysis of multiple borehole heat exchangers in the heat conduction and advection coupled layered soil

被引:0
作者
Jin G. [1 ]
Gong J. [1 ]
Zhang W. [1 ]
Xu F. [1 ]
Hu A. [1 ]
机构
[1] School of Energy & Environment, Inner Mongolia University of Science & Technology, Baotou
来源
Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering | 2021年 / 37卷 / 11期
关键词
Borehole heat exchangers; Ground source heat pumps; Heat transfer; Multiple-layered soil; Numerical simulation; Thermal conductivity;
D O I
10.11975/j.issn.1002-6819.2021.11.024
中图分类号
学科分类号
摘要
Safe, clean, and efficient geothermal energy has been widely popular in various countries, particularly for reducing carbon dioxide emissions and achieving the transition from fossil energy to renewable energy. A rational design of heat pump systems depends mainly on the accurate acquisition for the heat transfer of multiple Borehole Heat Exchangers (BHE) in complex soil. In the present study, a multiple-layered numerical model was established for three-dimensional multiple BHE considering the groundwater advection using Fluent software. The accuracy of the model was validated using a 48h thermal response test data. Two indexes were introduced to evaluate the performance, including the regional thermal efficiency (E) and Dynamic Performance Loss (DPL). Furthermore, an analysis was made to clarify the influence of the location and thickness of the advection layer on the heat transfer of multiple BHE in layered soil. The result indicated that there was a small difference of E between the layered and homogeneous models, when the advection velocity was 100 m/a, and the thickness of the advection layer was large. The heat transfer of multiple BHE in the layered soil was simplified as that in homogeneous soil under this condition. The E of multiple BHE was ignored, only to adjust the position and thickness of the soil layer with different thermal conductivities at a groundwater advection velocity of 100 m/a. It infers that there was a small effect of the variation in thermal conductivity in different depths of soil layers on the heat transfer of multiple BHE. Therefore, the backfill material with higher thermal conductivity should be balanced to use in the backfill layer of buried pipe in the multiple BHE, when the advection velocity of groundwater was 100 m/a. There was no influence of variable equivalent inlet velocity (0.115, 0.158, and 0.237 m/s) and inlet temperature (300, 310, and 320 K) on E the multiple BHE. The downstream DPL of the staggered arrangement multiple BHE with 3 m pipe spacing was only 1.27 percentage points higher than that of the aligned multiple BHE with 6 m pipe spacing, after 2 000 h of continuous operation under the groundwater advection velocity of 100 m/a. It was suggested that the borehole spacing of aligned and staggered arrangement should be 4 and 3 m, respectively, when advection velocity was 100m/a and the thickness of the advection layer was large. The average unit heat transfer rate of multiple BHE with 105 m advection layers increased by 24.4%, compared with that with 35 m advection layer. When the advection velocity was 100 m/a, the inlet temperature was 300 K, and the equivalent velocity in the pipe was 0.115 m/s, there was no effect of the advection layer location on the heat transfer of multiple BHE, whereas there was an obvious effect of the advection layer thickness on the heat transfer of multiple BHE. In addition, the E of multiple BHE was greater, while the DPL was lower, and the rate of stabilization was faster, as the advection velocity was larger. The findings can provide a sound reference for the rational design of multiple BHE in the layered soil with groundwater advection. © 2021, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
引用
收藏
页码:213 / 221
页数:8
相关论文
共 30 条
[1]  
Sarbu I, Sebarchievici C., General review of ground-source heat pump systems for heating and cooling of buildings, Energy and Buildings, 70, pp. 441-454, (2014)
[2]  
Wu Xuan, Liu Wei, Lu Ziye, Et al., Simulation on temperature variation characteristics of soil around buried pipe in process of heat storage and release, Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 33, 3, pp. 204-213, (2017)
[3]  
Li Xiaoxing, Hu Xiamin, Zhang Zhengwei, Calculation method of thermal response radius for vertical borehole heat exchangers, Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 31, 17, pp. 248-253, (2015)
[4]  
Zhang C X, Wang Y S, Liu Y F, Et al., Computational methods for ground thermal response of multiple borehole heat exchangers: A review, Renewable Energy, 127, pp. 461-473, (2018)
[5]  
Luo J, Zhao H F, Jia J, Et al., Study on operation management of borehole heat exchangers for a large-scale hybrid ground source heat pump system in China, Energy, 123, pp. 340-352, (2017)
[6]  
Katsura T, Shoji Y, Sakata Y, Et al., Method for calculation of ground temperature in scenario involving multiple ground heat exchangers considering groundwater advection, Energy and Buildings, (2020)
[7]  
Luo Zujiang, Du Jingjing, Heat exchange scheme simulation optimization for ground source heat pump system with buried pipes by thermal equilibrium analysis, Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE), 34, 13, pp. 246-254, (2018)
[8]  
Gultekin A, Aydin M, Sisman A., Thermal performance analysis of multiple borehole heat exchangers, Energy Conversion and Management, 122, pp. 544-551, (2016)
[9]  
Yuan Y P, Cao X L, Wang J Q, Et al., Thermal interaction of multiple ground heat exchangers under different intermittent ratio and separation distance, Applied Thermal Engineering, 108, pp. 277-286, (2016)
[10]  
Li yong, Mao Jinfeng, Geng Shibin, Et al., Analysis and optimization of multi-boreholes based on moving finite line source model, Acta Energiae Solaris Sinica, 36, 6, pp. 1287-1293, (2015)