Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system

被引:0
|
作者
TENG YuanJieCHEN ChenZHOU ChangXiangZHAO HongLi LAN MinBo Shanghai key Laboratory of Functional Materials Chemistry
Research Center of Analysis TestEast China University of Science and TechnologyShanghai China [200237 ]
机构
关键词
D O I
暂无
中图分类号
TP212.3 [生物传感器、医学传感器];
学科分类号
摘要
The screen-printed three-electrode system was applied to fabricate a new type of disposable amperometric xanthine oxidase biosensor.Carbon-working,carbon-counter and Ag/AgCl reference electrodes were all manually printed on the polyethylene terephthalate substrate forming the screen-printed three-electrode system by the conventional screen-printing process.As a mediator,Prussian blue could not only catalyze the electrochemical reduction of hydrogen peroxide produced from the enzyme reaction,but also keep the favorable potential around 0 V.The optimum operational conditions,including pH,potential and temperature,were investigated.The sensitivities of xanthine and hypoxanthine detections were 13.83 mA/M and 25.56 mA/M,respectively.A linear relationship was obtained in the concentration range between 0.10μM and 4.98μM for xanthine and between 0.50μM and 3.98μM for hypoxanthine.The small Michaelis-menten constant value of the xanthine oxidase biosensor was calculated to be 3.90 μM.The results indicate that the fabricated xanthine oxidase biosensor is effective and sensitive for the detection of xanthine and hypoxanthine.
引用
收藏
页码:2581 / 2586
页数:6
相关论文
共 50 条
  • [22] A paper-based amperometric glucose biosensor developed with Prussian Blue-modified screen-printed electrodes
    Sekar, Nadia Chandra
    Shaegh, Seyed Ali Mousavi
    Ng, Sum Huan
    Ge, Liya
    Tan, Swee Ngin
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 414 - 420
  • [23] A Disposable, Screen-Printed Electrode for the Amperometric Determination of Azide Based on the Immobilization with Catalase or Tyrosinase
    Yue Cui
    John P. Barford
    Reinhard Renneberg
    Analytical Sciences, 2006, 22 : 1279 - 1281
  • [24] Glucose biosensors based on a gold nanodendrite modified screen-printed electrode
    Liu, Hsi-Chien
    Tsai, Chung-Che
    Wang, Gou-Jen
    NANOTECHNOLOGY, 2013, 24 (21)
  • [25] A disposable, screen-printed electrode for the amperometric determination of azide based on the immobilization with catalase or tyrosinase
    Cui, Yue
    Barford, John P.
    Renneberg, Reinhard
    ANALYTICAL SCIENCES, 2006, 22 (10) : 1279 - 1281
  • [26] Exploring Electrochemistry: A Hydrogen Peroxide Sensor Based on a Screen-Printed Carbon Electrode Modified with Prussian Blue
    Todorov, Jovica
    McCarty, Gregory S.
    Sombers, Leslie A.
    JOURNAL OF CHEMICAL EDUCATION, 2023, 100 (12) : 4853 - 4859
  • [27] Catechol monophosphate as a new substrate for screen-printed amperometric biosensors with immobilized phosphatases
    Szydlowska, D
    Campàs, M
    Marty, JL
    Trojanowicz, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (02): : 787 - 796
  • [28] Amperometric fructose sensor based on ferrocyanide modified screen-printed carbon electrode
    Biscay, Julien
    Costa Rama, Estefania
    Gonzalez Garcia, Maria Begona
    Julio Reviejo, A.
    Pingarron Carrazon, Jose Manuel
    Costa Garcia, Agustin
    TALANTA, 2012, 88 : 432 - 438
  • [29] Microneedle-based transdermal electrochemical biosensors based on Prussian blue-gold nanohybrid modified screen-printed electrodes
    Pandey, Prem C.
    Pandey, Govind
    Narayan, Roger J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2021, 109 (01) : 33 - 49
  • [30] Characterisation of Prussian blue modified screen-printed electrodes for thiol detection
    Ricci, F
    Arduini, F
    Amine, A
    Moscone, D
    Palleschi, G
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 563 (02): : 229 - 237