In vitro degradation of 3D-printed polycaprolactone\biomimetic hydroxyapatite scaffolds: Impact of the sterilization method

被引:3
作者
del-Mazo-Barbara, Laura [1 ,2 ]
Gomez-Cuyas, Judith [1 ,2 ]
Martinez-Orozco, Leandro [3 ]
Perez, Orlando Santana [3 ]
Bou-Petit, Elisabeth [4 ]
Ginebra, Maria-Pau [1 ,2 ,5 ,6 ]
机构
[1] Univ Politecn Catalunya UPC, Dept Mat Sci & Engn, Biomat Biomech & Tissue Engn Grp, Av Eduard Maristany, Barcelona, Spain
[2] UPC, Barcelona Res Ctr Multiscale Sci & Engn, Barcelona, Spain
[3] UPC, Ecol & Biodegradable Polymers & Composites Eb POLI, Barcelona, Spain
[4] Univ Politecn Catalunya UPC, Dept Chem Engn, Barcelona 08028, Spain
[5] Inst Salud Carlos III, Ctr Invest Biomed Red Bioingn Biomat & Nanomed CIB, Madrid, Spain
[6] Barcelona Inst Sci & Technol, Inst Bioengn Catalonia IBEC, Barcelona, Spain
关键词
Polycaprolactone; Bone scaffold; 3D-printing; Hydroxyapatite; In vitro degradation; Hydrolytic degradation; ETHYLENE-OXIDE STERILIZATION; CALCIUM-PHOSPHATE CEMENTS; BIOMEDICAL APPLICATIONS; MEDICAL DEVICES; PCL;
D O I
10.1016/j.polymertesting.2024.108566
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the transition from the laboratory to the clinic, the sterilization of medical devices becomes a fundamental and mandatory step to ensure patient safety. This work evaluates the impact of three different sterilization methods autoclave, ethylene oxide and gamma irradiation - on the physicochemical properties and degradation kinetics of 3D-printed polycaprolactone\calcium deficient hydroxyapatite (PCL\CDHA) scaffolds for bone regeneration. The in vitro degradation test was performed in phosphate buffer saline solution at 47 degrees C for 18 weeks by recording the evolution of pH, scaffold morphology, swelling degree, mass loss as well as polymer content, molecular weight and crystallinity. The results showed that under thermally accelerated degradation, the scaffolds underwent hydrolytic bulk degradation without altering the pH of the soaking medium nor compromising the morphology and integrity of the constructs. Although the structural integrity of the scaffolds was maintained, autoclaving severely deteriorated the properties of the polymer, resulting in a faster degradation pattern, confirming that it is not an appropriate sterilization method for PCL\CDHA scaffolds. While ethylene oxide had no significant effect on degradation, gamma irradiation slightly accelerated hydrolysis by chain scission. However, due to the porous nature of the scaffolds, the use of ethylene oxide is inadvisable due to the risk of gas trapping in the pores. Therefore, gamma irradiation, a non-toxic, effective, predictable and reproducible sterilization method, is considered the most appropriate.
引用
收藏
页数:15
相关论文
共 67 条
[1]   In Vitro Hydrolytic Degradation of Polyester-Based Scaffolds under Static and Dynamic Conditions in a Customized Perfusion Bioreactor [J].
Alaman-Diez, Pilar ;
Garcia-Gareta, Elena ;
Francisco Napal, Pedro ;
Arruebo, Manuel ;
Angeles Perez, Maria .
MATERIALS, 2022, 15 (07)
[2]  
Anderson James M., 1995, P223
[3]  
[Anonymous], 2014, ISO 11135
[4]  
[Anonymous], 2018, 11137 ISO
[5]   Osteogenesis by foamed and 3D-printed nanostructured calcium phosphate scaffolds: Effect of pore architecture [J].
Barba, Albert ;
Maazouz, Yassine ;
Diez-Escudero, Anna ;
Rappe, Katrin ;
Espanol, Montserrat ;
Montufar, Edgar B. ;
Ohman-Magi, Caroline ;
Persson, Cecilia ;
Fontecha, Pedro ;
Manzanares, Maria-Cristina ;
Franch, Jordi ;
Ginebra, Maria-Pau .
ACTA BIOMATERIALIA, 2018, 79 :135-147
[6]   A comprehensive study of acid and base treatment of 3D printed poly (ε-caprolactone) scaffolds to tailor surface characteristics [J].
Bartnikowski, Michal ;
Abdal-hay, Abdalla ;
Bartnikowski, Nicole J. ;
Kim, Yu Kyoung ;
Ivanovski, Saso .
APPLIED SURFACE SCIENCE, 2021, 555
[7]   Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment [J].
Bartnikowski, Michal ;
Dargaville, Tim R. ;
Ivanovski, Saso ;
Hutmacher, Dietmar W. .
PROGRESS IN POLYMER SCIENCE, 2019, 96 :1-20
[8]  
Bohner M, 2000, INJURY, V31, pS37
[9]   Characterisation of bone regeneration in 3D printed ductile PCL/PEG/hydroxyapatite scaffolds with high ceramic microparticle concentrations [J].
Cao, Chuanliang ;
Huang, Pengren ;
Prasopthum, Aruna ;
Parsons, Andrew J. ;
Ai, Fanrong ;
Yang, Jing .
BIOMATERIALS SCIENCE, 2021, 10 (01) :138-152
[10]   Lamellar stack formation and degradative behaviors of hydrolytically degraded poly(e-caprolactone) and poly(glycolide-e-caprolactone) blended fibers [J].
Chung, Amy S. ;
Hwang, Ho Seong ;
Das, Debobrato ;
Zuk, Patricia ;
McAllister, David R. ;
Wu, Benjamin M. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (01) :274-284