Cuff-based blood pressure measurement: challenges and solutions

被引:4
|
作者
Pilz, N. [1 ,2 ]
Picone, D. S. [3 ,4 ]
Patzak, A. [5 ]
Opatz, O. S. [1 ]
Lindner, T. [1 ]
Fesseler, L. [1 ]
Heinz, V. [1 ]
Bothe, T. L. [1 ,3 ]
机构
[1] Charite Univ Med Berlin, Inst Physiol, Ctr Space Med & Extreme Environm Berlin, Virchowweg 6, D-10117 Berlin, Germany
[2] Hannover Med Sch, Dept Cardiol & Angiol, Hannover, Germany
[3] Univ Sydney, Sydney Sch Hlth Sci, Sydney, Australia
[4] Univ Tasmania, Menzies Inst Med Res, Hobart, Australia
[5] Charite Univ Med Berlin, Inst Physiol, D-10117 Berlin, Germany
基金
英国医学研究理事会;
关键词
Blood pressure monitoring; hypertension; cuff-based blood pressure measurement; accuracy of blood pressure measurement; home blood pressure monitoring; ambulatory blood pressure monitoring; office blood pressure monitoring; MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; MEASURING DEVICES; ATRIAL-FIBRILLATION; UNIVERSAL STANDARD; SLEEP-APNEA; HYPERTENSION/INTERNATIONAL ORGANIZATION; CLINICAL-PRACTICE; HYPERTENSION; HOME; VALIDATION;
D O I
10.1080/08037051.2024.2402368
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
ObjectiveAccurate measurement of arterial blood pressure (BP) is crucial for the diagnosis, monitoring, and treatment of hypertension. This narrative review highlights the challenges associated with conventional (cuff-based) BP measurement and potential solutions. This work covers each method of cuff-based BP measurement, as well as cuffless alternatives, but is primarily focused on ambulatory BP monitoring.ResultsManual BP measurement requires stringent training and standardized protocols which are often difficult to ensure in stressful and time-restricted clinical office blood pressure monitoring (OBPM) scenarios. Home Blood pressure monitoring (HBPM) can identify white-coat and masked hypertension but strongly depends on patient adherence to measurement techniques and procedure. The widespread use of nonvalidated automated HBPM devices raises further concerns about measurement accuracy. Ambulatory blood pressure measurement (ABPM) may be used in addition to OBPM. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping, which are the BP values most predictive for major adverse cardiac events. Nonetheless, ABPM is limited by its non-continuous nature and susceptibility to measurement artefacts. This leads to poor overall reproducibility of ABPM results, especially regarding clinical parameters such as BP variability or dipping patterns.ConclusionsCuff-based BP measurement, despite some limitations, is vital for cardiovascular health assessment in clinical practice. Given the wide range of methodological limitations, the paradigm's potential for improvement is not yet fully realized. There are impactful and easily incorporated opportunities for innovation regarding the enhancement of measurement accuracy and reliability as well as the clinical interpretation of the retrieved data. There is a clear need for continued research and technological advancement to improve BP measurement as the premier tool for cardiovascular disease detection and management. Accurate blood pressure measurement is crucial for diagnosing, monitoring, and treating hypertension and preventing cardiovascular diseases.Manual blood pressure monitoring is common but may not always be reliable due to the stress and time constraints in clinical settings. It also fails to detect white-coat and masked hypertension.Home blood pressure monitoring helps to identify white-coat and masked hypertension but depends on how well patients follow the measurement instructions. Many devices are not validated, raising concerns about their accuracy.Ambulatory blood pressure measurement may be used in addition to office blood pressure measurement because of its better reproducibility and higher predictive value. It is recommended to diagnose white-coat and masked hypertension as well as nocturnal BP and dipping. However, it and can be prone to errors, affecting the reliability of results like BP variability or night-time dipping patterns.Patient's posture, physical activity, and conditions like atrial fibrillation can influence BP readings.Automated BP devices often have limitations in detecting measurement artefacts, underscoring the need for technological improvements.Despite its limitations, cuff-based blood pressure measurement is essential in everyday clinical practice but has unlocked potential for improvement.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Cuffless Blood Pressure Measurement
    Mukkamala, Ramakrishna
    Stergiou, George S.
    Avolio, Alberto P.
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2022, 24 : 203 - 230
  • [32] Automated Office-Based Blood Pressure Measurement: an Overview and Guidance for Implementation in Primary Care
    Boonyasai, Romsai T.
    McCannon, Erika L.
    Landavaso, Joseph E.
    CURRENT HYPERTENSION REPORTS, 2019, 21 (04)
  • [33] Cuff-less continuous blood pressure measurement based on multiple types of information fusion
    Yin, Shuaiju
    Li, Gang
    Luo, Yongshun
    Lin, Ling
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68
  • [34] Effect of the shape of the cuff on blood pressure measurement in people with large arms
    Palatini, Paolo
    Benetti, Elisabetta
    Fania, Claudio
    Ermolao, Andrea
    Spinella, Paolo
    Battista, Francesca
    Gasperetti, Andrea
    Saladini, Francesca
    BLOOD PRESSURE, 2020, 29 (04) : 241 - 246
  • [35] How Important is the Recommended Slow Cuff Pressure Deflation Rate for Blood Pressure Measurement?
    Zheng, Dingchang
    Amoore, John N.
    Mieke, Stephan
    Murray, Alan
    ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (10) : 2584 - 2591
  • [36] Principles of Blood Pressure Measurement - Current Techniques, Office vs Ambulatory Blood Pressure Measurement.
    Vischer, Annina S.
    Burkard, Thilo
    HYPERTENSION: FROM BASIC RESEARCH TO CLINICAL PRACTICE, VOL 2, 2017, 956 : 85 - 96
  • [37] Impact of cuff positioning on blood pressure measurement accuracy: may a specially designed cuff make a difference?
    Bilo, Grzegorz
    Sala, Oscar
    Perego, Carlotta
    Faini, Andrea
    Gao, Lan
    Gluszewska, Anna
    Ochoa, Juan Eugenio
    Pellegrini, Dario
    Lonati, Laura Maria
    Parati, Gianfranco
    HYPERTENSION RESEARCH, 2017, 40 (06) : 573 - 580
  • [38] Blood Pressure Measurement: A KDOQI Perspective
    Drawz, Paul E.
    Beddhu, Srinivasan
    Kramer, Holly J.
    Rakotz, Michael
    Rocco, Michael V.
    Whelton, Paul K.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2020, 75 (03) : 426 - 434
  • [39] History and evolution of blood pressure measurement
    Noh, Su A.
    Kim, Hwang-Soo
    Kang, Si-Hyuck
    Yoon, Chang-Hwan
    Youn, Tae-Jin
    Chae, In-Ho
    CLINICAL HYPERTENSION, 2024, 30 (01)
  • [40] Blood Pressure Self-Measurement
    Wagner, Stefan
    HYPERTENSION: FROM BASIC RESEARCH TO CLINICAL PRACTICE, VOL 2, 2017, 956 : 97 - 107