Accuracy of intraocular lens power calculation formulae for the Yamane technique of secondary fixation: a systematic review and meta-analysis

被引:1
作者
Khowaja, Aly Hamza [1 ]
Ghazanfar, Altamash Shahriyar [1 ]
Tayyab, Haroon [2 ]
机构
[1] Aga Khan Univ, Med Coll, Karachi 74800, Pakistan
[2] Aga Khan Univ Hosp, Dept Ophthalmol & Visual Sci, Karachi 74800, Pakistan
关键词
Intrascleral fixation; Yamane technique; Intraocular lenses; Refractive error; Predictive error; IOL power calculation formulae; REFRACTIVE OUTCOMES; CLINICAL-OUTCOMES; SCLERAL FIXATION; IMPLANTATION; EYES; CHAMBER; MANAGEMENT; BIOMETRY;
D O I
10.1007/s00417-024-06603-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective This systematic review and meta-analysis aims to assess the refractive outcomes of the Yamane technique for intrascleral fixation of intraocular lenses (SF-IOL) and compare the predictive ability of the various intraocular lens power calculation formulae commonly used in conjunction with the technique. Methods A literature search was conducted in the Medline, Scopus, and Cochrane Library databases for articles published from January 2014 to May 2023. Studies that met the predetermined inclusion criteria were included and subjected to analysis. The primary outcome evaluated was the refractive predictive error, defined as the difference between predicted refraction and post-operative manifest refraction. Result Eleven studies met the inclusion criteria, with a cumulative sample size of 615 patients (mean age: 66.6 years). Various IOL formulae were used, with SRK/T being the most frequently adopted formula. The overall mean refractive predictive error for all formulae combined was -0.02 D, which was not statistically significant (p = 0.99). Subgroup analysis for individual formulae also showed no significant difference from predicted error for any formula (p > 0.05). Conclusion The Yamane technique for SF-IOL shows promising refractive outcomes, and the choice of IOL power calculation formula should be tailored based on patient characteristics and surgeon preference. No formula demonstrated superior predictive ability over others. Further research is needed to develop formulae specifically for eyes with secondary aphakia and poor capsular support.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 44 条
[1]   Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules [J].
Agarwal, Amar ;
Kumar, Dhivya Ashok ;
Jacob, Soosan ;
Baid, Chandresh ;
Agarwal, Athiya ;
Srinivasan, Sridhar .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) :1433-1438
[2]  
[Anonymous], 2023, KANE FORMULA INTERNE
[3]   Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8108 eyes after cataract surgery with biometry by partial coherence interferometry [J].
Aristodemou, Petros ;
Cartwright, Nathaniel E. Knox ;
Sparrow, John M. ;
Johnston, Robert L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (01) :63-71
[4]   Comparison of Outcomes of Primary Anterior Chamber Versus Secondary Scleral-Fixated Intraocular Lens Implantation in Complicated Cataract Surgeries [J].
Chan, Tommy C. Y. ;
Lam, Jasmine K. M. ;
Jhanji, Vishal ;
Li, Emmy Y. M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (02) :221-226
[5]   Advancements in intraocular lens power calculation formulas [J].
Chung, Jinkwon ;
Bu, Jennifer J. ;
Afshari, Natalie A. .
CURRENT OPINION IN OPHTHALMOLOGY, 2022, 33 (01) :35-40
[6]   Comparison of the Kane formula with existing formulas for intraocular lens power selection [J].
Connell, Benjamin J. ;
Kane, Jack X. .
BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01)
[7]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[8]   Incidence and risk factors of late in-the-bag intraocular lens dislocation: Evaluation of 140 eyes between 1992 and 2012 [J].
Dabrowska-Kloda, Kinga ;
Kloda, Tomasz ;
Boudiaf, Sara ;
Jakobsson, Gurmar ;
Stenevi, Ulf .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (07) :1376-1382
[9]   Standardizing constants for ultrasonic biometry, keratometry, and intraocular lens power calculations [J].
Holladay, JT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (09) :1356-1370
[10]   Intraocular lens exchange due to incorrect lens power [J].
Jin, George J. C. ;
Crandall, Alan S. ;
Jones, Jason J. .
OPHTHALMOLOGY, 2007, 114 (03) :417-424