Development and validation of 3D printed anthropomorphic head phantom with eccentric holes for medical LINAC quality assurance testing in stereotactic radiosurgery

被引:0
作者
Nabhan, A. K. Shahi [1 ]
Saxena, Kritik [1 ]
Puzhakkal, Niyas [2 ]
Mathew, Jose [1 ]
Lawrence, K. Deepak [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Calicut, India
[2] MVR Canc Ctr & Res Inst, Dept Radiat Oncol, Calicut, India
关键词
Stereotactic radiosurgery; Linear accelerator; Anthropomorphic phantom; 3D printing; Treatment planning system; Patient specific quality assurance; WATER EQUIVALENCE; DOSIMETER;
D O I
10.1016/j.medengphy.2024.104217
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stereotactic Radiosurgery (SRS) for brain tumors using Medical Linear Accelerator (LINAC) demands high precision and accuracy. A specific Quality Assurance (QA) is essential for every patient undergoing SRS to protect nearby non-cancerous cells by ensuring that the X-ray beams are targeted according to tumor position. In this work, a water-filled generic anthropomorphic head phantom consisting of two removable parts with eccentric holes was developed using Additive Manufacturing (AM) process for performing QA in SRS. In the patient specific QA, the planned radiation dose using Treatment Planning System (TPS) was compared with the dose measured in the phantom. Also, the energy consistency of radiation beams was tested at 200 MU for different energy beams at the central and eccentric holes of the phantom using an ionization chamber. Experimentally examined results show that planned doses in TPS are reaching the target within a 5% deviation. The ratio of the dose delivered in the eccentric hole to the dose delivered to the central hole shows variations of less than 2% for the energy consistency test. The designed, low-cost water-filled anthropomorphic phantom is observed to improve positioning verification and accurate dosimetry of patient-specific QA in SRS treatment.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] Manufacturing and evaluation of a multi-purpose Iranian head and neck anthropomorphic phantom called MIHAN
    Ahmadi, Mohammad
    Anarestani, Meysam Ramezani
    Tabrizi, Sanaz Hariri
    Azma, Zohreh
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (7-8) : 1611 - 1620
  • [2] Challenges to curing primary brain tumours
    Aldape, Kenneth
    Brindle, Kevin M.
    Chesler, Louis
    Chopra, Rajesh
    Gajjar, Amar
    Gilbert, Mark R.
    Gottardo, Nicholas
    Gutmann, David H.
    Hargrave, Darren
    Holland, Eric C.
    Jones, David T. W.
    Joyce, Johanna A.
    Kearns, Pamela
    Kieran, Mark W.
    Mellinghoff, Ingo K.
    Merchant, Melinda
    Pfister, Stefan M.
    Pollard, Steven M.
    Ramaswamy, Vijay
    Rich, Jeremy N.
    Robinson, Giles W.
    Rowitch, David H.
    Sampson, John H.
    Taylor, Michael D.
    Workman, Paul
    Gilbertson, Richard J.
    [J]. NATURE REVIEWS CLINICAL ONCOLOGY, 2019, 16 (08) : 509 - 520
  • [3] 3-D Quality Assurance in CyberKnife Radiotherapy Using a Novel N-(3-methoxypropyl) Acrylamide Polymer Gel Dosimeter and Optical CT
    Awad, Samer, I
    Moftah, Belal
    Basfer, Ahmed
    Almousa, Akram A.
    Al Kafi, M. Abdullah
    Eyadeh, Molham M.
    Rabaeh, Khalid A.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2019, 161 : 34 - 41
  • [4] The developmental origin of brain tumours: a cellular and molecular framework
    Azzarelli, Roberta
    Simons, Benjamin D.
    Philpott, Anna
    [J]. DEVELOPMENT, 2018, 145 (10):
  • [5] Dual-energy CT evaluation of 3D printed materials for radiotherapy applications
    Fonseca, Gabriel P.
    Rezaeifar, Behzad
    Lackner, Niklas
    Haanen, Britt
    Reniers, Brigitte
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (03)
  • [6] Water equivalence of a solid phantom material for radiation dosimetry applications
    Gargett, Maegan A.
    Briggs, Adam R.
    Booth, Jeremy T.
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 14 : 43 - 47
  • [7] Creation of an anthropomorphic CT head phantom for verification of image segmentation
    Holmes, Robin B.
    Negus, Ian S.
    Wiltshire, Sophie J.
    Thorne, Gareth C.
    Young, Peter
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : 2380 - 2391
  • [8] hopkinsmedicine, Computed tomography (CT or CAT) scan of the abdomen
  • [9] Quasi-simultaneous 3D printing of muscle-, lung- and bone-equivalent media: a proof-of-concept study
    Kairn, T.
    Zahrani, M.
    Cassim, N.
    Livingstone, A. G.
    Charles, P. H.
    Crowe, S. B.
    [J]. PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 701 - 710
  • [10] Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance
    Kamomae, Takeshi
    Shimizu, Hidetoshi
    Nakaya, Takayoshi
    Okudaira, Kuniyasu
    Aoyama, Takahiro
    Oguchi, Hiroshi
    Komori, Masataka
    Kawamura, Mariko
    Ohtakara, Kazuhiro
    Monzen, Hajime
    Itoh, Yoshiyuki
    Naganawa, Shinji
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 205 - 211