Functional Design Analysis of Two Current Extended-Depth-of-Focus Intraocular Lenses

被引:0
作者
Mendroch, Damian [1 ]
Oberheide, Uwe [1 ]
Altmeyer, Stefan [1 ]
机构
[1] Cologne Univ Appl Sci, Inst Appl Opt & Elect, Betzdorfer Str 2, D-50679 Cologne, Germany
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2024年 / 13卷 / 08期
关键词
intraocular lens; cataract; raytracing; simulation; lens metrology; extended depth of focus; mathematical modelling; CONTACT-LENSES; POWER PROFILES; ABERRATIONS;
D O I
10.1167/tvst.13.8.33
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the differences between two extended depth-of-focus intraocular lenses, the Alcon IQ Vivity and the Bausch & Lomb LuxSmart and to compare them with a simple monofocal lens, the Alcon IQ, using a simulation-based approach. Methods: A mathematical lens model was created for each lens type based on a measured surface geometry. The lens model was then used in a raytracer to calculate a refractive power map of the lens and a ray propagation image for the focal zone. Results: The simulations confirm the enhanced depth of focus of these two lenses. There are apparent differences between the models. For the Vivity, more light is directed into the far focus in low light conditions, whereas the LuxSmart behaves more pupil independent and prioritizes intermediate vision. Conclusions: The simulation-based approach was effective in evaluating and comparing the design aspects of these lenses. It can be positioned as a valuable third tool for lens characterization, complementing in vivo studies and in vitro measurements. Translational Relevance: With this approach not only focusing on the resulting optical performance, but the underlying functional mechanisms, it paves the way forward for a better adaptation to the individual needs and preferences of patients.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] A comparative study of two presbyopia-correcting intraocular lenses combining bifocal and extended depth-of-focus profiles
    Kim, Jeongmin
    Kim, Tae-im
    Seo, Kyoung Yul
    Tchah, Hungwon
    Koh, Kyungmin
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [22] Positioning of enhanced monofocal intraocular lenses between conventional monofocal and extended depth of focus lenses: a scoping review
    Joaquín Fernández
    Carlos Rocha-de-Lossada
    Francisco Zamorano-Martín
    Marina Rodríguez-Calvo-de-Mora
    Manuel Rodríguez-Vallejo
    BMC Ophthalmology, 23
  • [23] Small Aperture IC-8 Extended-Depth-of-Focus Intraocular Lens in Cataract Surgery: A Systematic Review
    Sanchez-Gonzalez, Jose-Maria
    Sanchez-Gonzalez, Maria Carmen
    De-Hita-Cantalejo, Concepcion
    Ballesteros-Sanchez, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (16)
  • [24] Visual Outcomes Following Non-Diffractive Extended-Depth-of-Focus Intraocular Lens Implantation in Patients with Epiretinal Membrane in One Eye and Bilateral Cataracts
    Sararols, Laura
    Guarro, Merce
    Vazquez, Meritxell
    Ruiz, Sergi
    Lopez, Elena
    Biarnes, Marc
    BIOMEDICINES, 2024, 12 (11)
  • [25] Design and Optical Analysis of a Refractive Aspheric Intraocular Lens with Extended Depth of Focus
    Li, Kunqi
    Chen, Xiaoqin
    Bian, Yayan
    Xing, Yuwei
    Li, Xiaolan
    Liu, Dongyu
    Liu, Yongji
    Seeger, Thomas
    OPTICS, 2023, 4 (01): : 146 - 155
  • [26] Clinical Outcomes of Patients Implanted with Bifocal and Extended Depth of Focus Intraocular Lenses
    Park, Su Hwan
    Kim, Sung Il
    Ahn, Jung Hyo
    Shin, Jong Hoon
    Kim, Su Jin
    Lee, Ji Eun
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2019, 60 (09): : 835 - 842
  • [27] Extended Depth-of-Field Intraocular Lenses: An Update
    Kanclerz, Piotr
    Toto, Francesca
    Grzybowski, Andrzej
    Alio, Jorge L.
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2020, 9 (03): : 194 - 202
  • [28] Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony
    Nowik, Katarzyna Ewa
    Nowik, Kamil
    Kanclerz, Piotr
    Szaflik, Jacek Pawel
    CLINICAL OPHTHALMOLOGY, 2022, 16 : 1613 - 1621
  • [29] Comparison of two extended depth of focus intraocular lenses with a monofocal lens: a multi-centre randomised trial
    Reinhard, Thomas
    Maier, Philip
    Boehringer, Daniel
    Bertelmann, Eckart
    Brockmann, Tobias
    Kiraly, Laszlo
    Salom, David
    Piovella, Matteo
    Colonval, Stephane
    Mendicute, Javier
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (02) : 431 - 442
  • [30] Trade-Off Asymmetric Profile for Extended-Depth-of-Focus Ocular Lens
    Romero, Lenny A.
    Marrugo, Andres G.
    Millan, Maria S.
    PHOTONICS, 2022, 9 (02)