A Novel Resynchronization Circuit to Enable High-Accuracy PTP Timestamping

被引:0
|
作者
Shao, Chengjia [1 ]
Xu, Zhen [1 ]
Ranganathan, Harihara S. [1 ]
机构
[1] Skyworks Solut Inc, Mixed Signal Solut Business Unit, Austin, TX 78702 USA
关键词
IEEE-1588; network synchronization; physical layer transceiver (PHY) timestamping; precision time protocol (PTP);
D O I
10.1109/TIM.2024.3420369
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Precision time protocol (PTP) is widely used in network synchronization applications to achieve high-accuracy time and phase alignment that has become increasingly important in the era of 5G. This article discusses a method to improve hardware timestamping accuracy and, thus, enhance the time error (TE) performance in PTP systems. In many practical network systems, there is a need to have independent clock domains for PTP and for the Ethernet physical layer transceiver (PHY) system. The clock domain crossing of the time-of-day (ToD) timestamp values from the PTP domain to the PHY domain is a major source of TE. This work presents a design named fine-count lock loop (FLL) that can reduce the clock-domain-crossing error down to +/- 100 ps using an external phase measurement circuit. When integrated into a PTP system, the design achieved +/- 4.4-ns constant TE (cTE) and 4.74-ns filtered maximum absolute TE (Max|TEL|) to meet the International Telecommunication Union (ITU) Class D specification for PTP performance.
引用
收藏
页码:1 / 1
页数:8
相关论文
共 50 条
  • [41] HIGH-ACCURACY CHROMIUM PLATING
    不详
    MACHINERY AND PRODUCTION ENGINEERING, 1975, 126 (3254): : 353 - 353
  • [42] HIGH-ACCURACY CNC CHUCKER
    VASILASH, GS
    MANUFACTURING ENGINEERING, 1979, 83 (03): : 71 - 71
  • [43] High-accuracy liquid biopsies
    Beatriz Bellosillo
    Clara Montagut
    Nature Medicine, 2019, 25 : 1820 - 1821
  • [44] A high-accuracy blackbody for CLARREO
    Latvakoski, Harri
    Watson, Mike
    Topham, Shane
    Scott, Deron
    Wojcik, Mike
    Bingham, Gail
    INFRARED REMOTE SENSING AND INSTRUMENTATION XVIII, 2010, 7808
  • [45] High-Accuracy Gaging with SPC
    不详
    MANUFACTURING ENGINEERING, 2009, 143 (02): : 27 - 27
  • [46] HIGH-ACCURACY BRIDGE AMPLIFIER
    SHELL, D
    ELECTRONICS WORLD & WIRELESS WORLD, 1990, 96 (1653): : 582 - 583
  • [47] High-accuracy linear scale
    不详
    MANUFACTURING ENGINEERING, 2007, 138 (05): : 56 - +
  • [48] HIGH-ACCURACY SAMPLING WATTMETER
    STENBAKKEN, GN
    DOLEV, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1992, 41 (06) : 974 - 978
  • [49] HIGH-ACCURACY INTERPOLATION OF STRESSES
    BERES, E
    ACTA TECHNICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1980, 91 (3-4): : 257 - 263
  • [50] High-Accuracy Heading Determination
    El-Osery, Aly
    Bruder, Stephen
    Laughlin, Darren
    2013 8TH INTERNATIONAL CONFERENCE ON SYSTEM OF SYSTEMS ENGINEERING (SOSE), 2013, : 308 - 313