The analysis of tear meniscus parameters during daily soft contact lens wear using optical coherence tomography

被引:0
|
作者
Dogan, Levent [1 ]
Arslan, Gurcan Dogukan [1 ]
机构
[1] Tatvan State Hosp, Dept Ophthalmol, Bitlis, Turkiye
关键词
Soft contact lens; Ocular discomfort; Tear meniscus; Turbidity; Optic coherence tomography; DRY EYE; OSMOLARITY; DISCOMFORT; CYTOKINES; SYMPTOMS; CORNEAL; FILM;
D O I
10.1007/s00417-024-06606-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate tear meniscus parameters in soft contact lens wearers (SCL) using optical coherence tomography (OCT) and ImageJ software. Methods This prospective study included 50 soft contact lens wearers (group 1: 25 symptomatic SCL wearers (SCLW), group 2: 25 asymptomatic SCL wearers (ASCW)) and 25 healthy non-CL wearers (group 3 (NCLW)). SCLs were fitted on each eye of CL wearers, and the lower tear meniscus was imaged using OCT before CL insertion, immediately afterward, and reimaged 2, 5 and 10 h after insertion. Tear meniscus parameters, including tear meniscus height (TMH), depth (TMD), turbidity, and percentage area occupied by particles (PAOP) were measured in all groups. Results Turbidity and PAOP measurements at baseline in SCLW were significantly higher than in other groups (p < 0.05). There was no significant difference between TMH, TMD, turbidity, and PAOP parameters calculated at baseline visit and two hours after SCL insertion in all groups (p > 0.05 for 2 comparisons). The symptomatic SCL users had a significant decrease in TMH and TMD in the fifth hour. The turbidity and PAOP measurements of SCLW and ASCW at the fifth and tenth hours were significantly higher than those of NCLW (p < 0.05). Conclusion TMD and height TMH decrease throughout the day in all participants; however, a significant decrease in these parameters was observed only in symptomatic SCL users at the fifth hour, at the earliest. As the duration of CL wear increases, turbidity and PAOP even in asymptomatic SCL wearers become significantly higher than those in healthy non-CL wearers.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [31] Assessment of Tear Meniscus with Optical Coherence Tomography in Thyroid-Associated Ophtalmopathy
    Sizmaz, Selcuk
    Altan-Yaycioglu, Rana
    Bakiner, Okan Sefa
    Bozkirli, Emre
    Coban-Karatas, Muge
    Ulas, Burak
    CURRENT EYE RESEARCH, 2014, 39 (04) : 323 - 328
  • [32] Deep learning segmentation for optical coherence tomography measurements of the lower tear meniscus
    Stegmann, Hannes
    Werkmeister, Rene M.
    Pfister, Martin
    Garhoefer, Gerhard
    Schmetterer, Leopold
    Dos Santos, Valentin Aranha
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (03) : 1539 - 1554
  • [33] Evaluating of Tear Meniscus Parameters with Optical Coherent Tomography in Dry-Eye Patients
    Demirok, Gulizar Soyugelen
    Gurdal, Canan
    Sarac, Ozge
    Ceran, Basak Bostanci
    Can, Izzet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2013, 43 (04): : 258 - 262
  • [34] Age-related Variations of Human Tear Meniscus and Diagnosis of Dry Eye With Fourier-domain Anterior Segment Optical Coherence Tomography
    Qiu, Xiaodi
    Gong, Lan
    Sun, Xinghuai
    Jin, Huan
    CORNEA, 2011, 30 (05) : 543 - 549
  • [35] Correlation Between Optical Coherence Tomography-Derived Assessments of Lower Tear Meniscus Parameters and Clinical Features of Dry Eye Disease
    Nguyen, Pho
    Huang, David
    Li, Yan
    Sadda, Srinivas R.
    Ramos, Sylvia
    Pappuru, Rajeev R.
    Yiu, Samuel C.
    CORNEA, 2012, 31 (06) : 680 - 685
  • [36] Tear film evaluation and management in soft contact lens wear: a systematic approach
    Downie, Laura E.
    Craig, Jennifer P.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (05) : 438 - 458
  • [37] Tear Meniscus Evaluation by Anterior Segment Swept-Source Optical Coherence Tomography
    Fukuda, Reina
    Usui, Tomohiko
    Miyai, Takashi
    Yamagami, Satoru
    Amano, Shiro
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (04) : 620 - 624
  • [38] CRF-based segmentation of human tear meniscus obtained with optical coherence tomography
    Tsechpenakis, Gabriel
    Wang, Jianhua
    2007 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-7, 2007, : 2761 - +
  • [39] Evaluation of Tear Meniscus Dynamics Using Anterior Segment Swept-Source Optical Coherence Tomography After Topical Solution Instillation for Dry Eye
    Akiyama-Fukuda, Reina
    Usui, Tomohiko
    Yoshida, Tatsuya
    Yamagami, Satoru
    CORNEA, 2016, 35 (05) : 654 - 658
  • [40] Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
    Montani, Giancarlo
    Martino, Maurizio
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 1521 - 1531