The analysis of tear meniscus parameters during daily soft contact lens wear using optical coherence tomography

被引:0
|
作者
Dogan, Levent [1 ]
Arslan, Gurcan Dogukan [1 ]
机构
[1] Tatvan State Hosp, Dept Ophthalmol, Bitlis, Turkiye
关键词
Soft contact lens; Ocular discomfort; Tear meniscus; Turbidity; Optic coherence tomography; DRY EYE; OSMOLARITY; DISCOMFORT; CYTOKINES; SYMPTOMS; CORNEAL; FILM;
D O I
10.1007/s00417-024-06606-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate tear meniscus parameters in soft contact lens wearers (SCL) using optical coherence tomography (OCT) and ImageJ software. Methods This prospective study included 50 soft contact lens wearers (group 1: 25 symptomatic SCL wearers (SCLW), group 2: 25 asymptomatic SCL wearers (ASCW)) and 25 healthy non-CL wearers (group 3 (NCLW)). SCLs were fitted on each eye of CL wearers, and the lower tear meniscus was imaged using OCT before CL insertion, immediately afterward, and reimaged 2, 5 and 10 h after insertion. Tear meniscus parameters, including tear meniscus height (TMH), depth (TMD), turbidity, and percentage area occupied by particles (PAOP) were measured in all groups. Results Turbidity and PAOP measurements at baseline in SCLW were significantly higher than in other groups (p < 0.05). There was no significant difference between TMH, TMD, turbidity, and PAOP parameters calculated at baseline visit and two hours after SCL insertion in all groups (p > 0.05 for 2 comparisons). The symptomatic SCL users had a significant decrease in TMH and TMD in the fifth hour. The turbidity and PAOP measurements of SCLW and ASCW at the fifth and tenth hours were significantly higher than those of NCLW (p < 0.05). Conclusion TMD and height TMH decrease throughout the day in all participants; however, a significant decrease in these parameters was observed only in symptomatic SCL users at the fifth hour, at the earliest. As the duration of CL wear increases, turbidity and PAOP even in asymptomatic SCL wearers become significantly higher than those in healthy non-CL wearers.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [1] The Analysis of Tear Meniscus in Soft Contact Lens Wearers by Spectral Optical Coherence Tomography
    Le, Qihua
    Jiang, Chunhui
    Jiang, Alice C.
    Xu, Jianjiang
    CORNEA, 2009, 28 (08) : 851 - 855
  • [2] Tear meniscus particle analysis with anterior segment optical coherence tomography in keratoconus
    Seyyar, Sevim Ayca
    Buyukbayram, Saban
    Soysal, Gizem Gurbostan
    Ayla, Serhat
    Dogan, Levent
    Tokuc, Ecem Onder
    Mercanli, Murat
    Mete, Alper
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (08) : 1136 - 1141
  • [3] Evaluation of the Tear Meniscus Using Optical Coherence Tomography in Meibomian Gland Dysfunction
    Dogan, Levent
    Arslan, Gurcan Dogukan
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2023, 31 (09) : 1785 - 1791
  • [4] Characterization of Soft Contact Lens Edge Fitting during Daily Wear Using Ultrahigh-Resolution Optical Coherence Tomography
    Cui, Lele
    Chen, Sisi
    Zhou, Weihe
    Sheng, Kaixuan
    Zhang, Lei
    Shen, Meixiao
    Li, Ming
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [5] Using Optical Coherence Tomography to Assess Corneoscleral Morphology After Soft Contact Lens Wear
    Alonso-Caneiro, David
    Shaw, Alyra J.
    Collins, Michael J.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (11) : 1619 - 1626
  • [6] Assessment of corneal thickness and tear meniscus during contact-lens wear
    Del Aguila-Carrasco, Antonio J.
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Esteve-Taboada, Jose J.
    Montes-Mico, Robert
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (03): : 185 - 193
  • [7] Assessment of the Tear Meniscus Using Optical Coherence Tomography in Patients With Type 2 Diabetes Mellitus
    Baek, Jiwon
    Doh, Sang Hee
    Chung, Sung Kun
    CORNEA, 2015, 34 (12) : 1534 - 1540
  • [8] Tear Meniscus Measurement by Spectral Optical Coherence Tomography
    Czajkowski, Grzegorz
    Kaluzny, Bartlomiej J.
    Laudencka, Adriana
    Malukiewicz, Grazyna
    Kaluzny, Jakub J.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (03) : 336 - 342
  • [9] Agreement Between Stratus and Visante Optical Coherence Tomography Systems in Tear Meniscus Measurements
    Savini, Giacomo
    Goto, Eiki
    Carbonelli, Michele
    Barboni, Piero
    Huang, David
    CORNEA, 2009, 28 (02) : 148 - 151
  • [10] Analysis of Tear Meniscus Change after Strabismus Surgery Using Optical Coherence Tomography
    Kim, Ji Hye
    Kim, Che Ron
    Kim, Seong Jae
    Chung, In Young
    Seo, Seong Wook
    Yoo, Ji Myong
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (12): : 1932 - 1938