Numerical Modeling of Uniaxial Corroded Reinforced Concrete Columns Exposed to Fire

被引:0
作者
Ba, Guangzhong [1 ]
Wu, Weijian [2 ]
Dai, Hongchao [3 ]
Jiao, Yu [1 ]
Zhang, Jie [1 ]
机构
[1] Shanghai Maritime Univ, Coll Ocean Sci & Engn, Shanghai 201306, Peoples R China
[2] Huaneng Fujian Energy Dev Co Ltd, Fuzhou Branch, Fuzhou 350200, Peoples R China
[3] Shanghai Housing Qual Inspect Stn Co Ltd, Shanghai 200063, Peoples R China
基金
中国国家自然科学基金;
关键词
fire; corrosion; reinforced concrete columns; fire resistance; numerical simulation; FINITE-ELEMENT; RESISTANCE; CORROSION;
D O I
10.3390/buildings14092737
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Corroded concrete structures remain at risk of fire damage throughout their lifespan. This study explores the fire resistance of reinforced concrete columns, considering the simultaneous impact of corrosion and high temperatures. Thermal-structural models of the corroded concrete columns are developed using SAFIR software (2022). The numerical results are compared with published test data on temperature distributions and axial displacement-time curves. Then, parametric analyses are conducted to investigate the influence of various factors, such as corrosion degree, concrete compressive strength, cover thickness, and fire exposure models, on the fire performance of the concrete columns. The findings reveal that corrosion significantly undermines fire resistance: notably, columns with severe corrosion exhibited a 47% reduction in fire resistance. Conversely, increased concrete strength can bolster the fire resistance of intact columns, particularly when the concrete cover is minimal. Enhancing the cover thickness proves to be an effective strategy to mitigate the thermal degradation of steel reinforcements, thereby extending the columns' fire resistance by as much as 23%. The study introduces coefficients to quantify the effects of corrosion, fire exposure, material strength, and cover thickness, culminating in a practical formula to calculate the fire endurance of corroded reinforced concrete columns. This formula could complement existing fire safety regulations.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Corroded reinforced concrete columns under simulated seismic loading
    Rajput, Aditya Singh
    Sharma, Umesh Kumar
    ENGINEERING STRUCTURES, 2018, 171 : 453 - 463
  • [22] Numerical modeling of repaired reinforced concrete bridge columns
    Salehi, Mohammad
    Sideris, Petros
    DesRoches, Reginald
    ENGINEERING STRUCTURES, 2022, 253
  • [23] Electrochemical performance of corroded reinforced concrete columns strengthened with fiber reinforced polymer
    Liang, Hongjun
    Li, Shan
    Lu, Yiyan
    Hu, Jiyue
    Liu, Zhenzhen
    COMPOSITE STRUCTURES, 2019, 207 : 576 - 588
  • [24] Fire Performance of Steel Reinforced Concrete Columns
    Han, Lin-Hai
    Tan, Qing-Hua
    Song, Tian-Yi
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (04)
  • [25] Residual flexural capacity of corroded reinforced concrete beams after exposure to fire
    Ba, Guangzhong
    Wu, Weijian
    Liu, Caiwei
    Liu, Hao
    Miao, Jijun
    STRUCTURES, 2024, 61
  • [26] Flexural behaviour of corroded RC beams exposed to fire
    Tariq, Faraz
    Bhargava, Pradeep
    STRUCTURES, 2021, 33 : 1366 - 1375
  • [27] A numerical approach for modeling response of fiber reinforced polymer strengthened concrete slabs exposed to fire
    Kodur, V. K. R.
    Bhatt, P. P.
    COMPOSITE STRUCTURES, 2018, 187 : 226 - 240
  • [28] NUMERICAL INVESTIGATION OF SEVERELY CORRODED REINFORCED CONCRETE BEAMS
    Zhu, Ji-hua
    Chen, Ju
    ADVANCES IN CONCRETE STRUCTURAL DURABILITY, PROCEEDINGS OF ICDCS2008, VOLS 1 AND 2, 2008, : 756 - 760
  • [29] Reinforced concrete columns exposed to standard fire: Comparison among different constitutive models for concrete at high temperature
    Bamonte, P.
    Lo Monte, F.
    FIRE SAFETY JOURNAL, 2015, 71 : 310 - 323
  • [30] Using alkali-activated slag ferrocement to strengthen corroded reinforced concrete columns
    Fang, Shuai
    Lam, Eddie Siu-Shu
    Wong, Wing-Ying
    MATERIALS AND STRUCTURES, 2017, 50 (01)