Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion

被引:0
|
作者
Gong, Matthew F. [1 ]
Finger, Logan E. [1 ]
Letter, Christina [2 ]
Amirian, Soheyla [3 ]
Parmanto, Bambang [2 ]
O'Malley, Michael [1 ]
Klatt, Brian A. [1 ]
Tafti, Ahmad P. [2 ]
Plate, Johannes F. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Hlth & Rehabil Sci, Dept Hlth Informat Management, Pittsburgh, PA USA
[3] Pace Univ, Seidenberg Sch Comp Sci & Informat Syst, New York, NY USA
关键词
orthopaedic surgery; adult reconstruction; postoperative rehabilitation; technology; knee arthroplasty; STIFFNESS; JOINTS; HIP;
D O I
10.1055/a-2388-0812
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee range of motion (ROM) is an important indicator of knee function. Outside the clinical setting, patients may not be able to accurately assess knee ROM, which may impair recovery following trauma or surgery. This study aims to validate a smartphone mobile application developed to measure knee ROM compared to visual and goniometer ROM measurements. A knee ROM Android mobile application was developed to measure knee ROM. Patients > 18 years old presenting to an orthopaedic clinic with native knee complaints were approached to participate. Knee ROM was measured bilaterally by an arthroplasty-trained surgeon using (1) vision, (2) goniometer, and (3) the mobile application. Measurements were compared in flexion and extension using a one-way analysis of variance with post hoc Tukey test (alpha = 0.05). Eighty-four knee ROM measurements (40 left, 44 right) were obtained in 47 patients. Median Kellgren- Lawrence grade from available radiographs was grade 3. In flexion, mobile application (117.6 + 14.7 degrees) measurements were not significantly different from visual (116.1 + 13.6 degrees) or goniometer (116.2 + 13.6 degrees) measurements. In extension, mobile application (4.8 + 7.3 degrees) measurements were significantly different from visual (1.9+ 4.1 degrees) measurements on post hoc analysis (p < 0.01), while no differences were present compared to goniometer (3.1 +5.8 degrees) measurements. Our study found that a mobile application for evaluating knee ROM was noninferior to goniometer-based measurements performed by an arthroplasty-trained surgeon. Future studies will investigate this application's utility in (1) remote patient care, (2) accelerating recovery during rehabilitation, (3) detecting early postoperative complications including arthrofibrosis, and (4) adding additional functionalities to the application to provide more detail-oriented descriptive analyses of patient knee function.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [41] The acute effect of roller massager on knee joint range of motion and muscle pain in older adults with total knee arthroplasty
    Yokochi, Masanobu
    Nakamura, Masatoshi
    Iwata, Ayaka
    Kaneko, Ryota
    Watanabe, Shiho
    Konrad, Andreas
    Yamada, Noboru
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2023, 23 (02) : 223 - 227
  • [42] Arthroscopic lysis of adhesions improves knee range of motion after fixation of intra-articular fractures about the knee
    Gittings, Daniel
    Hesketh, Patrick
    Dattilo, Jonathan
    Zgonis, Miltiadis
    Kelly, John
    Mehta, Samir
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (12) : 1631 - 1635
  • [43] The Influence of Weather Conditions on the Diurnal Variation in Range of Motion in Older Adults with Knee Osteoarthritis
    Iconaru, Elena Ioana
    Tarcau, Emilian
    Ciucurel, Constantin
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [44] Range of motion as an outcome measure for knee osteoarthritis interventions in clinical trials: an integrated review
    Epskamp, Samantha
    Dibley, Hayley
    Ray, Elizabeth
    Bond, Nicole
    White, Joshua
    Wilkinson, Amanda
    Chapple, Cathy M.
    PHYSICAL THERAPY REVIEWS, 2020, 25 (5-6) : 462 - 481
  • [45] Static progressive stretch improves range of motion in arthrofibrosis following total knee arthroplasty
    Bonutti, Peter M.
    Marulanda, German A.
    McGrath, Mike S.
    Mont, Michael A.
    Zywiel, Michael G.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (02) : 194 - 199
  • [46] How often is functional range of motion obtained by manipulation for stiff total knee arthroplasty?
    Choi, Ho-Rim
    Siliski, John
    Malchau, Henrik
    Freiberg, Andrew
    Rubash, Harry
    Kwon, Young-Min
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1641 - 1645
  • [47] Heterotopic Ossification Negatively Influences Range of Motion After Revision Total Knee Arthroplasty
    Gkiatas, Ioannis
    Xiang, William
    Nocon, Allina A.
    Youssef, Mark P.
    Tarity, T. David
    Sculco, Peter K.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (08): : 2907 - 2912
  • [48] How often is functional range of motion obtained by manipulation for stiff total knee arthroplasty?
    Ho-Rim Choi
    John Siliski
    Henrik Malchau
    Andrew Freiberg
    Harry Rubash
    Young-Min Kwon
    International Orthopaedics, 2014, 38 : 1641 - 1645
  • [49] Actors and intentions in the development process of a mobile phone platform for self-management of hypertension
    Ranerup, Agneta
    Hallberg, Inger
    INFORMATICS FOR HEALTH & SOCIAL CARE, 2015, 40 (04): : 299 - 318
  • [50] The systematic development of a mobile phone-delivered brief intervention for hazardous drinking in India
    Nadkarni, Abhijit
    Costa, Sheina
    Gupta, Devika
    Fernandes, Danielle
    Catalano, Alexander
    Velleman, Richard
    Sambari, Seema
    Pednekar, Subhash
    Hussain, Farah
    D'Souza, Ethel
    Houde, Amruta
    Chaudhuri, Neal
    Heath, Anna
    JOURNAL OF SUBSTANCE ABUSE TREATMENT, 2021, 126