A highly sensitive and selective electrochemical sensing probe for detection of Edoxaban anticoagulant drug residue in environmental water and drug formulations

被引:0
作者
Alwael, H. [1 ]
Dabi, M. M. [1 ]
Bahaidarah, E. A. [1 ]
Abduljabbar, T. N. [1 ]
Alshareef, F. M. [1 ]
Hatahet, O. M. [1 ]
Soomro, M. T. [2 ]
El-Shahawi, M. S. [1 ]
机构
[1] King Abdulaziz Univ, Fac Sci, Dept Chem, Jeddah, Saudi Arabia
[2] King Abdulaziz Univ, Ctr Excellence Environm Studies CEES, Jeddah, Saudi Arabia
关键词
Anticoagulant drugs; direct-oral anticoagulant; electrochemical analysis; square wave stripping voltammetry; analytical applications; GLASSY-CARBON ELECTRODE; HUMAN PLASMA; MS/MS METHOD; PHARMACEUTICALS; QUANTIFICATION; RIVAROXABAN; APIXABAN; MICROPARTICLES; BEHAVIOR; SENSOR;
D O I
10.1080/03067319.2024.2372459
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Anticoagulant drugs currently play a crucial role in preventing severe deep vein thrombosis, heart attacks, heart valve diseases and contribute to the regulation of blood flow. Thus, the existing study reports the redox behaviour of Edoxaban (EDX) anticoagulant drug at bare glassy carbon electrode (GCE) for establishing sensitive, and selective adsorptive square wave - cathodic stripping voltammtric (Ads SW-CSV) probe for EDX detection. Under the optimal analytical parameters, the probe displayed good linear dynamic range (LDR) of EDX from 1.0 x 10-6 - 1.0 x 10-5 M. The probe displayed probe sensitivity, limits of detection (LOD) and quantification (LOQ) of 18.5 mu A mu M-1 cm-2, 3.3 x 10-7 and 1.0 x 10-6 M, respectively. The probe offered quick response, good anti-interference ability towards multiple co-existing species, good recovery (99.21 +/- 5.02), reproducibility, and repeatability with relative standard deviation (RSD) of +/- 3.0% at 1.0 x 10-6 M of EDX (n = 3). Intraday and interday precisions of the probe were 99.8 +/- 1.74 and 99.54 +/- 2.08% at 1.0 x 10-6 M of EDX, respectively. The probe was fruitfully applied for EDX detection in its formulations and its residue in water samples with good recovery (99.76 +/- 3.768-101.43 +/- 0.09) and precision (RSD < 3%) at low and high EDX levels. The tabulated Student t test (ttab=2.78) was higher than the experimental texp = 1.3-1.7 at 95% probability (n = 5). The probe exhibited good sensitivity and selectivity towards EDX detection in drug formulation and environmental water samples. The probe has long-term stability and high level of anti-interference performance towards EDX detection.
引用
收藏
页数:19
相关论文
共 74 条
[1]   Electrochemical Studies and the Electrode Reaction Mechanism of Ferrocene and Naphthoquinones in Microemulsion Medium at GC Electrode [J].
Abdallah, M. ;
Alharbi, Ahmed ;
Morad, Moataz ;
Hameed, Ahmed M. ;
Al-Juaid, Salih S. ;
Foad, N. ;
Mabrouk, E. M. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2020, 15 (07) :6522-6548
[2]   SPOOC (Sensor for Periodic Observation of Choline): An Integrated Lab-on-a-Spoon Platform for At-Home Quantification of Choline in Infant Formula [J].
Al-Shami, Abdulrahman ;
Amirghasemi, Farbod ;
Soleimani, Ali ;
Nejad, Sina Khazaee ;
Ong, Victor ;
Berkmen, Alara ;
Ainla, Alar ;
Mousavi, Maral P. S. .
SMALL, 2024, 20 (31)
[3]  
Alemu H, 2003, B CHEM SOC ETHIOPIA, V17, P95
[4]   A sensitive and high-performance electrochemical detection of nitrite in water samples based on Sonochemical synthesized Strontium Ferrite Nanochain architectures [J].
Annalakshmi, Muthaiah ;
Balaji, Ramachandran ;
Chen, Shen-Ming ;
Chen, Tse-Wei ;
Huang, Yi-Chen .
ELECTROCHIMICA ACTA, 2020, 360 (360)
[5]   Calculation of the Tafel slope and reaction order of the oxygen evolution reaction between pH 12 and pH 14 for the adsorbate mechanism [J].
Antipin, Denis ;
Risch, Marcel .
ELECTROCHEMICAL SCIENCE ADVANCES, 2023, 3 (06)
[6]   Firstly Electrochemical Examination of Myosmine at Glassy Carbon Electrode: Sensitive Determination in Tobacco Leaves by Differential Pulse Voltammetry [J].
Aral, Tarik ;
Onal, Gunay ;
Keskin, Ertugrul ;
Levent, Abdulkadir .
ELECTROANALYSIS, 2021, 33 (11) :2392-2399
[7]   Simple LC-MS/MS method using core-shell ODS microparticles for the simultaneous quantitation of edoxaban and its major metabolites in human plasma [J].
Ariizumi, Saki ;
Naito, Takafumi ;
Hoshikawa, Kohei ;
Akutsu, Shunta ;
Saotome, Masao ;
Maekawa, Yuichiro ;
Kawakami, Junichi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1146
[8]   The effectiveness of early anticoagulant treatment in Covid-19 patients [J].
Arslan, Yakup ;
Yilmaz, Gulden ;
Dogan, Deniz ;
Hasirci, Mine ;
Cetindogan, Hatice ;
Ocal, Nesrin ;
Savasci, Umit ;
Fidan, Gonca ;
Tasci, Canturk .
PHLEBOLOGY, 2021, 36 (05) :384-391
[9]   Voltammetric studies and spectroscopic investigations of the interaction of an anticancer drug bevacizumab-DNA and analytical applications of disposable pencil graphite sensor [J].
Aslan, Mehmet ;
Aydin, Firat ;
Levent, Abdulkadir .
TALANTA, 2023, 265
[10]   A Novel Nanoparticles-Based Electrochemical Sensing Platform for Sensitive Detection of Oral Anticoagulant; Edoxaban in Human Plasma [J].
Ayish, Nada S. ;
Marzouk, Hoda M. ;
El-Zeany, Badr A. ;
Fayed, Ahmed S. .
ELECTROANALYSIS, 2022, 34 (08) :1266-1272