ElectrochemCap: an integrated detection for loop-mediated isothermal amplification reactions

被引:0
|
作者
Rioboo-Legaspi, P. [1 ]
Costa-Rama, E. [1 ]
Fernandez-Abedul, M. T. [1 ]
机构
[1] Univ Oviedo, Fac Quim, Dept Quim Fis & Analit, Oviedo, Spain
关键词
SENSORS;
D O I
10.1039/d4lc00395k
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Loop-mediated isothermal amplification (LAMP) of genetic materials has emerged as a powerful molecular biology technique with great potential to be a standard point-of-care (POC) technique. This method has found several applications, but it still presents challenges for its direct on-site application, particularly in terms of integrated reaction and detection systems and the risk of carryover contamination. In this work, we propose an innovative solution - an electrochemical microcentrifuge tube cap (ElectrochemCap) based on a screen-printed electrode, a 3D printed adapter and an adhesive layer - which integrates the amplification reaction and its subsequent electrochemical detection in a single device. The design, fabrication, and electrochemical characterization of the ElectrochemCap are reported here, demonstrating its suitability for LAMP detection. Rapidly emerging technologies, such as 3D printing or xurography, are the basis of a prototype that has been validated for the detection of SARS-CoV-2 using reverse transcription LAMP (RT-LAMP), achieving results comparable to those obtained by gold-standard RT-qPCR. Moreover, we have explored the versatility of the ElectrochemCap presenting several additional designs (for containers with different volumes, shapes and materials, as well as multiplexed approaches), expanding its potential applications. Overall, the ElectrochemCap represents an affordable, versatile, and marketable innovation for integrated quantitative electrochemical detection, with enormous possibilities in bioelectroanalytical procedures and portable laboratory setups. An electrochemical microcentrifuge tube cap (ElectrochemCap) for integrated (bio)electroanalysis is demonstrated with a LAMP amplification reaction and its subsequent electrochemical detection. Adaptations for different containers are also presented.
引用
收藏
页码:4085 / 4095
页数:11
相关论文
共 50 条
  • [1] An integrated microfluidic loop-mediated isothermal amplification platform for koi herpesvirus detection
    Chen, Shih-Chu
    Liu, Chan-Chiung
    Wang, Yao-Nan
    Fu, Lung-Ming
    Shih, Sheng-Hong
    CHEMICAL ENGINEERING JOURNAL, 2018, 334 : 1828 - 1834
  • [2] Loop-mediated isothermal amplification for detection of African trypanosomes
    Kuboki, N
    Inoue, N
    Sakurai, T
    Di Cello, F
    Grab, DJ
    Suzuki, H
    Sugimoto, C
    Igarashi, I
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (12) : 5517 - 5524
  • [3] Detection of Xanthomonas oryzae by loop-mediated isothermal amplification
    Lang, J. M.
    Langlois, P.
    Nguyen, H.
    Cruz, C. M. Vera
    Purdie, L.
    Holton, T.
    Djikeng, A.
    Verdier, V.
    Leach, J. E.
    PHYTOPATHOLOGY, 2013, 103 (06) : 76 - 76
  • [4] Detection of Ralstonia solanacearum by loop-mediated isothermal amplification
    Kubota, R.
    Vine, B. G.
    Alvarez, A. M.
    Jenkins, D. M.
    PHYTOPATHOLOGY, 2008, 98 (09) : 1045 - 1051
  • [5] Detection of Botrytis cinerea by loop-mediated isothermal amplification
    Tomlinson, J. A.
    Dickinson, M. J.
    Boonham, N.
    LETTERS IN APPLIED MICROBIOLOGY, 2010, 51 (06) : 650 - 657
  • [6] Loop-mediated isothermal amplification for the detection of goose circovirus
    Grzegorz Woźniakowski
    Wojciech Kozdruń
    Elżbieta Samorek-Salamonowicz
    Virology Journal, 9
  • [7] Loop-mediated isothermal amplification for the detection of goose circovirus
    Wozniakowski, Grzegorz
    Kozdrun, Wojciech
    Samorek-Salamonowicz, Elzbieta
    VIROLOGY JOURNAL, 2012, 9
  • [8] Loop-mediated isothermal amplification for the detection of Pseudomonas fuscovaginae
    Ash, G. J.
    Lang, J. M.
    Triplett, L. R.
    Stodart, B. J.
    Verdier, V.
    Leach, J. E.
    PHYTOPATHOLOGY, 2013, 103 (06) : 10 - 10
  • [9] Strategies for the Voltammetric Detection of Loop-Mediated Isothermal Amplification
    Marangoni, Jesse M. M.
    Ng, Kenneth K. S.
    Emadi, Arezoo
    MICROMACHINES, 2023, 14 (02)
  • [10] Detection of fish nocardiosis by loop-mediated isothermal amplification
    Itano, T.
    Kawakami, H.
    Kono, T.
    Sakai, M.
    JOURNAL OF APPLIED MICROBIOLOGY, 2006, 100 (06) : 1381 - 1387