Enhancing flow-mediated dilation analysis by optimizing an open-source software with automated edge detection

被引:0
作者
Masterova, Kseniya S. [1 ,2 ]
Wang, Jiefei [3 ]
Mack, Courtney [2 ]
Moro, Tatiana [4 ]
Deer, Rachel [5 ]
Volpi, Elena [6 ,7 ]
机构
[1] Univ Texas Med Branch, Grad Sch Biomed Sci, Galveston, TX USA
[2] Univ Texas Med Branch, John Sealy Sch Med, Galveston, TX USA
[3] Univ Texas Med Branch, Dept Biostat, Galveston, TX USA
[4] Univ Padua, Dept Biomed Sci, Padua, Italy
[5] Univ Texas Med Branch, Ctr Recovery Phys Act & Nutr, Galveston, TX USA
[6] Univ Texas Med Branch, Sealy Ctr Aging, Galveston, TX 77555 USA
[7] Univ Texas Hlth Sci Ctr San Antonio, Barshop Inst, San Antonio, TX 78229 USA
基金
美国国家卫生研究院;
关键词
arterial diameter; edge detection; flow-mediated dilation; open-source; reliability; VALIDATION; HUMANS;
D O I
10.1152/japplphysiol.00063.2023
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Flow-mediated dilation (FMD) is a common measure of endothelial function and an indicator of vascular health. Automated software methods exist to improve the speed and accuracy of FMD analysis. Compared with commercial software, open-source software offers similar capabilities at a much lower cost while allowing for increased customization specific to users' needs. We introduced modifications to an existing open-source software, FloWave.us to better meet FMD analysis needs. The purpose of this study was to compare the repeatability and reliability of the modified FloWave.us software to the original software and to manual measurements. To assess these outcomes, duplex ultrasound imaging data from the popliteal artery in older adults were analyzed. The average percent FMD for the modified software was 6.98 +/- 3.68% and 7.27 +/- 3.81% for observer 1 and 2 respectively, compared with 9.17 +/- 4.91% and 10.70 +/- 4.47% with manual measurements and 5.07 +/- 31.79% with the original software for observer 1. The modified software and manual methods demonstrated higher intraobserver intraclass correlation coefficients (ICCs) for repeated measures for baseline diameter, peak diameter, and percent FMD compared with the original software. For percent FMD, the interobserver ICC was 0.593 for manual measurements and 0.723 for the modified software. With the modified method, an average of 97.7 +/- 2.4% of FMD videos frames were read, compared with only 17.9 +/- 15.0% frames read with the original method when analyzed by the same observer. Overall, this work further establishes open-source software as a robust and viable tool for FMD analysis and demonstrates improved reliability compared with the original software.
引用
收藏
页码:300 / 311
页数:12
相关论文
共 33 条
[1]   Model-Based Analysis of Flow-Mediated Dilation and Intima-Media Thickness [J].
Bartoli, G. ;
Menegaz, G. ;
Lisi, M. ;
Di Stolfo, G. ;
Dragoni, S. ;
Gori, T. .
INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2008, 2008 (01)
[2]  
Ben-Ezra S., 2022, FFT filter-clean your signals and display results!
[3]   Importance of measuring the time course of flow-mediated dilatation in humans [J].
Black, Mark A. ;
Cable, N. Timothy ;
Thijssen, Dick H. J. ;
Green, Daniel J. .
HYPERTENSION, 2008, 51 (02) :203-210
[4]  
Boashash B., 2016, TIME FREQUENCY SIGNA, P3
[5]  
Coolbaugh C., 2023, How to Use BMode.m
[6]  
Coolbaugh C, 2023, Getting Started
[7]   FloWave. US: validated, open-source, and flexible software for ultrasound blood flow analysis [J].
Coolbaugh, Crystal L. ;
Bush, Emily C. ;
Caskey, Charles F. ;
Damon, Bruce M. ;
Towse, Theodore F. .
JOURNAL OF APPLIED PHYSIOLOGY, 2016, 121 (04) :849-857
[8]   Validation of semi-automated flow-mediated dilation measurement in healthy volunteers [J].
Dobbie, Laurence J. ;
Mackin, Sharon T. ;
Hogarth, Katrina ;
Lonergan, Frances ;
Kannenkeril, Dennis ;
Brooksbank, Katriona ;
Delles, Christian .
BLOOD PRESSURE MONITORING, 2020, 25 (04) :216-223
[9]   Ultrasound Measurement of Vascular Distensibility Based on Edge Detection and Speckle Tracking Using Ultrasound DICOM Data [J].
Funes-Lora, Miguel Angel ;
Thelen, Brian J. ;
Shih, Albert J. ;
Hamilton, James ;
Rajaram, Nirmala ;
Lyu, Jingxuan ;
Zheng, Yihao ;
Morgan, Timothy ;
Weitzel, William F. .
ASAIO JOURNAL, 2022, 68 (01) :112-121
[10]   Evaluation of Endothelial Function by Flow Mediated Dilation: Methodological Issues and Clinical Importance [J].
Ghiadoni L. ;
Salvetti M. ;
Muiesan M.L. ;
Taddei S. .
High Blood Pressure & Cardiovascular Prevention, 2015, 22 (1) :17-22