Experimental study on startup characteristics of instant heat pump water heater with non-azeotropic natural blend

被引:2
|
作者
Ju, Fujun [1 ]
Hou, Qianlei [1 ]
Fan, Xiaowei [1 ,2 ]
Wu, Jiafeng [3 ]
Zheng, Huifan [1 ]
Liu, Qinglei [1 ]
Hou, Lihao [1 ]
Liu, Wenbo [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
[2] Henan Univ Urban Construction, Coll Energy & Bldg Environm Engn, Pingdingshan 467036, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Startup performances; Startup mode; Heat sink outlet temperature; Heat pump water heater; Natural blend; AIR-CONDITIONING SYSTEM; ROTARY-COMPRESSOR; DYNAMIC CHARACTERISTICS; REFRIGERANT MIGRATION; BEHAVIOR; PERFORMANCE; R290; SIMULATION; R-410A;
D O I
10.1016/j.csite.2024.104675
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct -heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient performance parameters. Both warm start and lower OTHS helps to quickly obtain hot water at the target temperature, mainly because the system startup time in the warm start was 16.73 % shorter than that in the cold start and the system gained the shortest startup time (1015 s) in low temperature condition. The transient heat sink outlet temperature had a rapid temperature rise section and a slow temperature rise section (STRS), and the STRS consumed 56.58 % - 66.67 % of the system starting time, so the improvement of STRS is the key to realize the fast startup. The effects of startup mode on the trends of transient performance parameters were memorably different, but the OTHS had no apparent effect on their trends. The transient refrigerant pressures and transient refrigerant temperatures had the fluctuations. The transient suction pressures had the minimum values (0.3925 - 0.5575 MPa), and both cold start mode and higher OTHS resulted in a decrease in the minimum value.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Experimental Study on the Performance of a Household Dual-Source Heat Pump Water Heater
    Gou, Xiang
    Liu, Shian
    Fu, Yang
    Zhang, Qiyan
    Iram, Saima
    Liu, Yingfan
    ENERGIES, 2018, 11 (10)
  • [42] NUMERICAL AND EXPERIMENTAL STUDY ON PERFORMANCE OF HEAT PUMP WATER HEATER WITH ELECTRONIC EXPANSION VALVE
    Li W-G
    Guo X-M
    Sun T
    Wang W-H
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 1559 - 1567
  • [43] Study on the operating characteristics of a solar heat pump water heater based on data fusion
    Xian, Ting
    Wu, Jianghong
    Zhang, Xin
    SOLAR ENERGY, 2020, 212 : 113 - 124
  • [44] Study on the operating characteristics of a solar heat pump water heater based on data fusion
    Xian, Ting
    Wu, Jianghong
    Zhang, Xin
    Solar Energy, 2020, 212 : 113 - 124
  • [45] Experimental Study on Characteristics of Trans-critical Heat Pump Water Heater Using Refrigerant HFC125
    Wang, Fang
    Lian, Zhiwei
    Fan, Xiaowei
    Wang, Fengkun
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1521 - 1528
  • [46] Experimental Study on Gas Cooler Heat Transfer Characteristics Applied in CO2 Supercritical Cycle Heat Pump Water Heater
    Liu, Yefeng
    Zhang, Hua
    Cai, Caoping
    Wu, Weidong
    Qi, Yingxia
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 323 - 329
  • [47] Experimental Study of Optimum Heat Rejection Pressure for a CO2 Heat Pump Water Heater
    Fan Xiaowei
    Zhang Xianping
    Wang Fengkun
    Ma Qiang
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 4, 2010, : 535 - +
  • [48] Analysis On The Operating Characteristics Of Solar Water Heater In Combination With Air Source Heat Pump Water Heater
    Jiang Ai-guo
    Wang Xiao-zhong
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING, PTS 1-3, 2012, 393-395 : 601 - 603
  • [49] Evaluation of non-azeotropic mixtures containing HFOs as potential refrigerants in refrigeration and high-temperature heat pump systems
    ZHANG ShengJun WANG HuaiXin GUO Tao Department of Thermal Energy and Refrigeration Engineering Tianjin University Tianjin China
    Science China(Technological Sciences), 2010, 53 (07) : 1855 - 1861
  • [50] Experimental Research of a Water-Source Heat Pump Water Heater System
    Zhao, Zhongchao
    Zhang, Yanrui
    Mi, Haojun
    Zhou, Yimeng
    Zhang, Yong
    ENERGIES, 2018, 11 (05)