Experimental study on startup characteristics of instant heat pump water heater with non-azeotropic natural blend

被引:2
|
作者
Ju, Fujun [1 ]
Hou, Qianlei [1 ]
Fan, Xiaowei [1 ,2 ]
Wu, Jiafeng [3 ]
Zheng, Huifan [1 ]
Liu, Qinglei [1 ]
Hou, Lihao [1 ]
Liu, Wenbo [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
[2] Henan Univ Urban Construction, Coll Energy & Bldg Environm Engn, Pingdingshan 467036, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Startup performances; Startup mode; Heat sink outlet temperature; Heat pump water heater; Natural blend; AIR-CONDITIONING SYSTEM; ROTARY-COMPRESSOR; DYNAMIC CHARACTERISTICS; REFRIGERANT MIGRATION; BEHAVIOR; PERFORMANCE; R290; SIMULATION; R-410A;
D O I
10.1016/j.csite.2024.104675
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct -heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient performance parameters. Both warm start and lower OTHS helps to quickly obtain hot water at the target temperature, mainly because the system startup time in the warm start was 16.73 % shorter than that in the cold start and the system gained the shortest startup time (1015 s) in low temperature condition. The transient heat sink outlet temperature had a rapid temperature rise section and a slow temperature rise section (STRS), and the STRS consumed 56.58 % - 66.67 % of the system starting time, so the improvement of STRS is the key to realize the fast startup. The effects of startup mode on the trends of transient performance parameters were memorably different, but the OTHS had no apparent effect on their trends. The transient refrigerant pressures and transient refrigerant temperatures had the fluctuations. The transient suction pressures had the minimum values (0.3925 - 0.5575 MPa), and both cold start mode and higher OTHS resulted in a decrease in the minimum value.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] AN EXPERIMENTAL ANALYSIS OF AIR SOURCE HEAT PUMP WATER HEATER
    Ozturk, M. Mete
    Erbay, L. Berrin
    ISI BILIMI VE TEKNIGI DERGISI-JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2012, 32 (01) : 117 - 127
  • [33] Experimental analysis on ground source heat pump water heater
    School of Energy and Environment, Southeast University, Nanjing 210096, China
    Huagong Xuebao, 2006, SUPPL. (125-130):
  • [34] Experimental study on the subcooled flow boiling of non-azeotropic mixtures in rhombic fin microchannels
    Xu, Ying
    Han, Hui
    Liu, Liang
    He, Yi
    Cui, Jiachen
    Li, Yuxing
    Li, Yan
    Wang, Cailin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 239
  • [35] CO2-heat pump water heater:: characteristics, system design and experimental results
    Neksa, P
    Rekstad, H
    Zakeri, GR
    Schiefloe, PA
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (03): : 172 - 179
  • [36] EXPERIMENTAL STUDY ON THE OPERATING PERFORMANCE OF A HEAT PUMP WATER HEATER WITH R417A
    Jiang, K.
    Liu, Y.
    Wang, F.
    Li, G. Y.
    Wang, X.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 595 - 601
  • [37] Experimental Study of the Performance of a New Developed Heat Pump Water Heater with Frozen Evaporator
    Guo, Xiaochao
    Ma, Zhixian
    Ma, Liangdong
    Zhang, Jili
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 1600 - 1605
  • [38] Experimental Study of the Compressor in a R410a Heat Pump Water Heater System
    Wang, Fengkun
    Fan, Xiaowei
    Lian, Zhiwei
    Wang, Fang
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 671 - 678
  • [39] CO2 Heat Pump Water Heater: System Design and Experimental Study
    Liu, Yefeng
    Zhuo, Zhiyang
    Zhang, Feng
    Bao, Tuanwei
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 131 - 142
  • [40] Experimental study of a control strategy for a cascade air source heat pump water heater
    Qu Minglu
    Fan Yanan
    Chen Jianbo
    Li Tianrui
    Li Zhao
    Li He
    APPLIED THERMAL ENGINEERING, 2017, 110 : 835 - 843