Experimental study on startup characteristics of instant heat pump water heater with non-azeotropic natural blend

被引:2
|
作者
Ju, Fujun [1 ]
Hou, Qianlei [1 ]
Fan, Xiaowei [1 ,2 ]
Wu, Jiafeng [3 ]
Zheng, Huifan [1 ]
Liu, Qinglei [1 ]
Hou, Lihao [1 ]
Liu, Wenbo [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
[2] Henan Univ Urban Construction, Coll Energy & Bldg Environm Engn, Pingdingshan 467036, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Startup performances; Startup mode; Heat sink outlet temperature; Heat pump water heater; Natural blend; AIR-CONDITIONING SYSTEM; ROTARY-COMPRESSOR; DYNAMIC CHARACTERISTICS; REFRIGERANT MIGRATION; BEHAVIOR; PERFORMANCE; R290; SIMULATION; R-410A;
D O I
10.1016/j.csite.2024.104675
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct -heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient performance parameters. Both warm start and lower OTHS helps to quickly obtain hot water at the target temperature, mainly because the system startup time in the warm start was 16.73 % shorter than that in the cold start and the system gained the shortest startup time (1015 s) in low temperature condition. The transient heat sink outlet temperature had a rapid temperature rise section and a slow temperature rise section (STRS), and the STRS consumed 56.58 % - 66.67 % of the system starting time, so the improvement of STRS is the key to realize the fast startup. The effects of startup mode on the trends of transient performance parameters were memorably different, but the OTHS had no apparent effect on their trends. The transient refrigerant pressures and transient refrigerant temperatures had the fluctuations. The transient suction pressures had the minimum values (0.3925 - 0.5575 MPa), and both cold start mode and higher OTHS resulted in a decrease in the minimum value.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A Comprehensive Experimental Investigation of Additives to Enhance Pool Boiling Heat Transfer of a Non-Azeotropic Mixture
    Xu, Chen
    Qian, Zuoqin
    Ren, Jie
    ENTROPY, 2022, 24 (11)
  • [22] Experimental study on CO 2 air source heat pump water heater
    Chen Q.
    Tong Y.
    Zhu Z.-J.
    Tang L.-M.
    Chen G.-M.
    Li J.-J.
    Chen, G.-M. (gmchen@zju.edu.cn), 1600, Zhejiang University (46): : 610 - 615
  • [23] Numerical and experimental study on heat pump water heater with PCM for thermal storage
    Long, Jian-You
    Zhu, Dong-Sheng
    ENERGY AND BUILDINGS, 2008, 40 (04) : 666 - 672
  • [24] Experimental study on thermoelectric heat pump low-temperature water heater
    Xie, Kangshan
    Yu, Jianlin
    Zhao, Hua
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2007, 41 (11): : 1338 - 1341
  • [25] High temperature hot water heat pump with non-azeotropic refrigerant mixture HCFC-22/HCFC-141b
    Li, TX
    Guo, KH
    Wang, RZ
    ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (15) : 2033 - 2040
  • [26] Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens
    LIU ZhongbingZHANG LingYANG ZhangXU MingHAN TianheCollege of Civil EngineeringHunan UniversityChangshaHunan China
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 131 - 135
  • [27] Experimental study of thermoelectric heat pump water heater with exhaust heat recovery from kitchens
    College of Civil Engineering, Hunan University, Changsha 410082, China
    Hunan Daxue Xuebao, 2009, SUPPL. (131-135):
  • [29] Experimental startup characteristics of a prototype pump delivering tap water
    Zhang, Yu-Liang
    Zhu, Zu-Chao
    Li, Wen-Guang
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2019, 41 (09)
  • [30] Experimental startup characteristics of a prototype pump delivering tap water
    Yu-Liang Zhang
    Zu-Chao Zhu
    Wen-Guang Li
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2019, 41