Experimental study on startup characteristics of instant heat pump water heater with non-azeotropic natural blend

被引:2
|
作者
Ju, Fujun [1 ]
Hou, Qianlei [1 ]
Fan, Xiaowei [1 ,2 ]
Wu, Jiafeng [3 ]
Zheng, Huifan [1 ]
Liu, Qinglei [1 ]
Hou, Lihao [1 ]
Liu, Wenbo [1 ]
机构
[1] Zhongyuan Univ Technol, Sch Energy & Environm, Zhengzhou 450007, Peoples R China
[2] Henan Univ Urban Construction, Coll Energy & Bldg Environm Engn, Pingdingshan 467036, Peoples R China
[3] Southeast Univ, Sch Energy & Environm, Nanjing 210096, Peoples R China
关键词
Startup performances; Startup mode; Heat sink outlet temperature; Heat pump water heater; Natural blend; AIR-CONDITIONING SYSTEM; ROTARY-COMPRESSOR; DYNAMIC CHARACTERISTICS; REFRIGERANT MIGRATION; BEHAVIOR; PERFORMANCE; R290; SIMULATION; R-410A;
D O I
10.1016/j.csite.2024.104675
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects of starting mode and outlet temperature of heat sink (OTHS) on the starting performances of direct -heated heat pump water heater using natural blend were investigated experimentally. The results indicated that both starting mode and OTHS had notable impact on starting time of transient performance parameters. Both warm start and lower OTHS helps to quickly obtain hot water at the target temperature, mainly because the system startup time in the warm start was 16.73 % shorter than that in the cold start and the system gained the shortest startup time (1015 s) in low temperature condition. The transient heat sink outlet temperature had a rapid temperature rise section and a slow temperature rise section (STRS), and the STRS consumed 56.58 % - 66.67 % of the system starting time, so the improvement of STRS is the key to realize the fast startup. The effects of startup mode on the trends of transient performance parameters were memorably different, but the OTHS had no apparent effect on their trends. The transient refrigerant pressures and transient refrigerant temperatures had the fluctuations. The transient suction pressures had the minimum values (0.3925 - 0.5575 MPa), and both cold start mode and higher OTHS resulted in a decrease in the minimum value.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Simulation of a geothermal heat pump with non-azeotropic mixture
    Zhao, PC
    Ding, GL
    Zhang, CL
    Zhao, L
    APPLIED THERMAL ENGINEERING, 2003, 23 (12) : 1515 - 1524
  • [2] Experimental research on geothermal heat pump system with non-azeotropic working fluids
    Zhao, PC
    Zhao, L
    Ding, GL
    Zhang, CL
    APPLIED THERMAL ENGINEERING, 2002, 22 (15) : 1749 - 1761
  • [3] Experimental evaluation of a non-azeotropic working fluid for geothermal heat pump system
    Zhao, L
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (9-10) : 1369 - 1378
  • [4] Experimental investigation of moderately high temperature water source heat pump with non-azeotropic refrigerant mixtures
    Zhang, Shengjun
    Wang, Huaixin
    Guo, Tao
    APPLIED ENERGY, 2010, 87 (05) : 1554 - 1561
  • [5] Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C
    Abdesselam, H.
    Masjuki, H. H.
    Saidur, R.
    Sattar, M. A.
    Guellal, M.
    INTERNATIONAL ENERGY JOURNAL, 2008, 9 (04): : 267 - 274
  • [6] Advanced exergy analysis of heat pump performance affected by heat transfer matching characteristics of non-azeotropic refrigerants
    Liang K.
    Feng C.
    Wang M.
    Dong B.
    Wang L.
    Liu R.
    Dong, Bin (dongbin@haust.edu.cn), 1600, Materials China (72): : 2038 - 2046
  • [7] Experimental study on condensation flow patterns and heat transfer characteristics of non-azeotropic and immiscible binary mixed vapors
    Zhang, Weilong
    Cheng, Min
    Chen, Yuxuan
    Zhu, Xun
    Liao, Qiang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2023, 184
  • [8] AN EXPERIMENTAL STUDY ON THERMOELECTRIC HEAT PUMP WATER HEATER
    Zhang, Ling
    Liu, Zhongbing
    Yang, Zhiang
    Xu, Min
    Han, Tianhe
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2163 - 2170
  • [9] HEAT-PUMP CYCLES WITH REFRIGERANT NON-AZEOTROPIC MIXTURES IN THERMODYNAMIC DIAGRAMS
    RADERMACHER, R
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1984, 26 (05): : 52 - 52
  • [10] Experimental study on nucleate boiling heat transfer of non-azeotropic refrigerant on microcolumn surfaces
    Wang, Qifan
    Su, Dandan
    Li, Jing
    Li, Minxia
    Dang, Chaobin
    Xu, Wenjie
    Wang, Chenxu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2025, 240