A high-performance wearable microneedle sensor based on a carboxylated carbon nanotube-carbon nanotube composite electrode for the simultaneous detection of uric acid and dopamine

被引:1
|
作者
Zhu, Jiachen [1 ,2 ]
Wang, Weiliang [3 ]
Chen, Gang [4 ]
Gao, Tian [4 ]
Gao, Zhiyong [1 ]
Peng, Liang [2 ]
Wang, Luwen [2 ]
Cai, Wei [1 ]
机构
[1] Harbin Inst Technol, Sch Mat Sci & Engn, Harbin 150001, Peoples R China
[2] Hangzhou City Univ, Sch Informat & Elect Engn, Hangzhou 310015, Peoples R China
[3] Fujian Med Univ, Epilepsy Ctr, Xiamen Humanity Hosp, Xiamen 361000, Peoples R China
[4] Jiaxing Univ, Dept Orthopaed, Jiaxing Key Lab Basic Res & Clin Translat Orthoped, Affiliated Hosp 2, Jiaxing 314000, Peoples R China
基金
中国国家自然科学基金;
关键词
Wearable sensor; Interstitial fluids; UA detection; DA detection; In vivo sensing; ASCORBIC-ACID; SENSITIVE DETECTION; BIOSENSOR; NANOPARTICLES; GLUCOSE;
D O I
10.1016/j.microc.2024.111607
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Uric acid (UA) and dopamine (DA) are crucial biomarkers in the human body. However, there is limited research on detecting UA or DA in subcutaneous interstitial fluid (SISF), and no studies on their simultaneous detection in SISF. Here, we developed an electrochemical microneedle sensor based on the carboxylated carbon nanotubes/ multiwalled carbon nanotubes (CCNT/CNT) composite electrode for the simultaneous detection of UA and DA. Highly carboxylated CCNT was prepared and mixed with CNT and organosilicon-modified acrylic resin to form the CCNT/CNT composite. The carboxyl functional groups of CCNT enhance the electrode's adsorption of UA and DA, while CNT improves electron conduction. The sensor achieves a wide linear detection range for UA (5-600 mu M) with high sensitivity (7.13 mu A mu M-1 cm(-2)) and linearity (R2 = 0.994), as well as a wide linear range for DA (2-200 mu M) with high sensitivity (13.31 mu A mu M-1 cm(-2)) and linearity (R-2 = 0.994). The sensor achieved simultaneous detection of DA and UA in artificial interstitial fluid (ISF), with sensitivity and linearity remaining nearly unchanged compared to that in PBS, and is not affected by high levels of ascorbic acid (AA). Finally, the sensor successfully detected changes in UA levels in ISF of subjects before and after alcohol consumption in vivo, demonstrating its practical application capabilities. This study presents a practical strategy for detecting human biomarkers characterized by low cost, easy fabrication and excellent performance of electrode materials, and a well-designed microneedle sensor preparation scheme, making it highly promising for further research extension.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] High-Performance, Wearable Thermoelectric Generator Based on a Highly Aligned Carbon Nanotube Sheet
    Choi, Jaeyoo
    Jung, Yeonsu
    Dun, Chaochao
    Park, Kyung Tae
    Gordon, Madeleine P.
    Haas, Kyle
    Yuan, Pengyu
    Kim, Heesuk
    Park, Chong Rae
    Urban, Jeffrey J.
    ACS APPLIED ENERGY MATERIALS, 2020, 3 (01): : 1199 - 1206
  • [32] Simultaneous Detection of Dopamine, Ascorbic Acid and Uric Acid by Palladium-Zinc Oxide Nanotube Modified Electrode
    Tang, Qian
    Chen, Meng-Ni
    Zhu, Guo-Dong
    Liu, Jian-Yun
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (09) : 1177 - 1184
  • [33] Application of a modified carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid
    Beitollahi, Hadi
    Mohadesi, Alireza
    Mahani, Saeedeh Khalilizadeh
    Akbari, Ali
    ANALYTICAL METHODS, 2012, 4 (04) : 1029 - 1035
  • [34] A review of high-performance carbon nanotube-based carbon fibers
    Lee, Dongju
    Heo, So Jeong
    Kim, Seo Gyun
    Ku, Bon-Cheol
    FUNCTIONAL COMPOSITES AND STRUCTURES, 2023, 5 (04):
  • [35] Carbon nanotube/carbon fiber electrodes via chemical vapor deposition for simultaneous determination of ascorbic acid, dopamine and uric acid
    Zhao, Yankun
    Yang, Zhen
    Fan, Wenxin
    Wang, Yunchao
    Li, Guangzhen
    Cong, Hailin
    Yuan, Hua
    ARABIAN JOURNAL OF CHEMISTRY, 2020, 13 (01) : 3266 - 3275
  • [36] Effects of oxyfluorination on a multi-walled carbon nanotube electrode for a high-performance glucose sensor
    Yu, Hye-Ryeon
    Kim, Jong Gu
    Im, Ji Sun
    Bae, Tae-Sung
    Lee, Young-Seak
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2012, 18 (02) : 674 - 679
  • [37] Water based homogenous carbon ink modified electrode as an efficient sensor system for simultaneous detection of ascorbic acid, dopamine and uric acid
    Dinesh, Bose
    Saraswathi, Ramiah
    Kumar, Annamalai Senthil
    ELECTROCHIMICA ACTA, 2017, 233 : 92 - 104
  • [38] Preparation of a MoS2/carbon nanotube composite as an electrode material for high-performance supercapacitors
    Chen, Xiaobo
    Ding, Jingguo
    Jiang, Jing
    Zhuang, Guoce
    Zhang, Zhihai
    Yang, Peizhi
    RSC ADVANCES, 2018, 8 (52): : 29488 - 29494
  • [39] Fabrication of graphene/carbon nanotube composite modified electrode for selective and sensitive determination of uric acid
    Liu, Zhengxiao
    Xia, Jianfei
    Wang, Zonghua
    Xia, Yanzhi
    Zhang, Feifei
    Xia, Linhua
    BIOTECHNOLOGY, CHEMICAL AND MATERIALS ENGINEERING II, PTS 1 AND 2, 2013, 641-642 : 562 - +
  • [40] Nafion/Ni(OH)2 nanoparticles-carbon nanotube composite modified glassy carbon electrode as a sensor for simultaneous determination of dopamine and serotonin in the presence of ascorbic acid
    Babaei, Ali
    Taheri, Ali Reza
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 543 - 551