Lateral Performance of Composite Wall with Cold-Formed Thin-Walled Steel-Concrete Sandwich Panel

被引:1
作者
Zou, Jian [1 ]
Cao, Baozhu [2 ]
Zeng, Xiang [1 ]
Zhang, Yuchuan [1 ]
机构
[1] Hainan Univ, Sch Civil Engn & Architecture, Haikou 570228, Peoples R China
[2] Weifang Univ, Civil & Transportat Engn Coll, Weifang 261061, Peoples R China
关键词
composite wall; cold-formed thin-walled steel; concrete insulation sandwich wall panel; lateral performance; cyclic loading tests; finite element analysis; BEHAVIOR; GYPSUM; STUD;
D O I
10.3390/buildings14092928
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the lateral performance of a cold-formed steel-concrete insulation sandwich panel composite wall, two full-scale specimens with different arrangements were designed. The specimens underwent cyclic loading tests to examine the failure characteristics of the composite wall, and lateral performance aspects such as the experimental hysteresis curve, skeleton curve, and characteristic value of the whole loading process were acquired. The experimental results indicate that the failure of the composite wall system was primarily caused by the failure of the connection; the overall lateral performance of composite walls with one wall panel at the bottom and two wall panels at the top (W1) was superior to that of composite walls with two wall panels at the bottom and one wall panel at the top (W2). When loaded to an inter-story drift ratio of 1/300, the composite wall did not exhibit any significant damage. A finite element (FE) model was developed and validated by the experiments. Factors affecting the shear bearing capacity were analyzed based on the FE model, including the yield strength of diagonal braces, the thickness of the diagonal braces, the arrangement pattern of the wall panels, the dimensions of the wall panels, and the strength of the connection of the L-shaped connector and the flat connector. The FE results show that all these factors can influence the lateral performance of the composite wall.
引用
收藏
页数:19
相关论文
共 32 条
[1]  
Almasabha G, 2023, ACI STRUCT J, V120, P253
[2]  
[Anonymous], 2019, GB/T50081-2019
[3]  
[Anonymous], 2010, Code for design of concrete structures
[4]  
[Anonymous], 2010, GB/T 228.1-2010
[5]  
[Anonymous], 2015, JPJ 101-2015 Specification for Seismic Test of Buildings
[6]  
[Anonymous], 2011, JGJ 227-2011
[7]   A Horizontal Stiffener Detailing for Shear Links at the Link-to-Column Connection in Eccentrically Braced Frames [J].
Chao, Shih-Ho ;
Almasabha, Ghassan ;
Price, Brandon ;
Jiansinlapadamrong, Chatchai .
JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (09)
[8]   Tests of Cold-Formed Steel T-Joints with Semi-Oval Hollow Section Chord [J].
Chen, Man-Tai ;
Zuo, Wenkang ;
Young, Ben .
JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (08)
[9]   Static and dynamic mechanical properties of expanded polystyrene [J].
Chen, Wensu ;
Hao, Hong ;
Hughes, Dylan ;
Shi, Yanchao ;
Cui, Jian ;
Li, Zhong-Xian .
MATERIALS & DESIGN, 2015, 69 :170-180
[10]   Steel sheathed cold-formed steel framed shear walls subjected to lateral and gravity loading [J].
DaBreo, J. ;
Balh, N. ;
Ong-Tone, C. ;
Rogers, C. A. .
THIN-WALLED STRUCTURES, 2014, 74 :232-245