Removal of ring artifacts in neutron tomography image slices

被引:0
作者
Salama, Gerges M. [1 ]
Zaky, Magdy M. [2 ]
Hamed, Hesham F. A. [1 ,3 ]
Abd El-Samie, Fathi E. [4 ,5 ]
Mahmoud, Imbaby I. [6 ]
Abd el Bar, Waleed [1 ,2 ]
机构
[1] Minia Univ, Fac Engn, Dept Elect Engn, Al Minya 61111, Egypt
[2] Egyptian Atom Energy Author AEA, ETRR 2, Inshas, Egypt
[3] Egyptian Russian Univ, Fac Engn, Cairo, Egypt
[4] Menoufia Univ, Fac Elect Engn, Dept Elect & Elect Commun Engn, Menoufia 32952, Egypt
[5] Princess Nourah Bint Abdulrahman Univ, Coll Comp & Informat Sci, Dept Informat Technol, POB 84428, Riyadh 11671, Saudi Arabia
[6] Egyptian Atom Energy Author, NCRRT, Cairo, Egypt
来源
JOURNAL OF OPTICS-INDIA | 2024年
关键词
Ring artifacts; Neutron tomography; CCD detectors; Wavelet-Fourier; Analysis; Image processing; RADIOGRAPHY; QUALITY;
D O I
10.1007/s12596-024-02131-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In neutron computed tomography (NCT) using charge-coupled device (CCD) detectors, stripe artifacts in a sinogram occur due to flawed or poor detector elements, which induce concentrated ring artifacts in the image. Such ring artifacts hide subtle elements of the region of interest of the image. An effective ring relic elimination system needs to be created depending upon post processing. In the separated sinogram, those ring relic positions are recognized, and faulty lines are remedied according to a back-projection algorithm. This article presents strategies for the detection, classification, and revision of ring artifacts in the sinogram area. The suggested method is suitable for NCT images with parallel shaft geometry. The identification algorithm depends on information-driven thresholds estimated on the mean and contrast of the sinogram. The ring artifacts have three types. Hence, a separate revision is required for each class.
引用
收藏
页数:10
相关论文
共 23 条
[1]   Removal of ring artifacts in CT imaging through detection and correction of stripes in the sinogram [J].
Abu Anas, Emran Mohammad ;
Lee, Soo Yeol ;
Hasan, Md. Kamrul .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6911-6930
[2]   3D images of paper obtained by phase-contrast X-ray micro tomography:: image quality and binarisation [J].
Antoine, C ;
Nygård, P ;
Gregersen, OW ;
Holmstad, R ;
Weitkamp, T ;
Rau, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 490 (1-2) :392-402
[3]   A Self-Adaptive Approach for the Detection and Correction of Stripes in the Sinogram: Suppression of Ring Artifacts in CT Imaging [J].
Ashrafuzzaman, A. N. M. ;
Lee, Soo Yeol ;
Hasan, Md Kamrul .
EURASIP JOURNAL ON ADVANCES IN SIGNAL PROCESSING, 2011,
[4]  
Ayat Karrar M.S., 2023, J. Adv. Eng. Trends
[5]  
Banhart J., 2008, ADV TOMOGRAPHIC METH
[6]  
Dierick M., 2005, PhD Thesis
[7]  
Hasan MK., 2010, Removal of ring Artifacts in micro-CT Imaging Using Iterative Morphological Filter
[8]  
Ketcham R.A., 2006, Proc. SPIE
[9]   Ring artifact correction for high-resolution micro CT [J].
Kyriakou, Yiannis ;
Prell, Daniel ;
Kalender, Willi A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (17) :N385-N391
[10]  
Munch B., 2009, Opt. Express