Lightning Current Measurement Method Using Rogowski Coil Based on Integral Circuit with Low-Frequency Attenuation Feedback

被引:0
|
作者
Xiao, Yiping [1 ,2 ]
Jiao, Hongjian [1 ]
Huo, Feng [3 ]
Shen, Zongtao [1 ]
机构
[1] Hubei Univ Technol, Sch Elect & Elect Engn, Wuhan 430068, Peoples R China
[2] Hubei Univ Technol, Hubei Key Lab High Efficiency Utilizat Solar Energ, Wuhan 430068, Peoples R China
[3] China Elect Power Res Inst Co Ltd, Wuhan 43007, Peoples R China
关键词
Rogowski coil; lightning current measurement; low-frequency distortion; integral correction; low-frequency attenuation feedback network; CURRENT SENSOR;
D O I
10.3390/s24154980
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lightning current measurement method using a Rogowski coil based on an integral circuit with low-frequency attenuation feedback was proposed to address the issue of low-frequency distortion in the measurement of lightning currents on transmission lines using Rogowski coils. Firstly, the causes of low-frequency distortion in lightning current measurements using Rogowski coils were analyzed from the perspective of frequency domains. On this basis, an integration correction optimization circuit with a low-frequency attenuation feedback network was designed to correct the low-frequency distortion. The optimized integration circuit can also reduce the impact of low-frequency noise and the DC bias of the operational amplifier (op-amp) on the integration circuit due to the high low-frequency gain. Additionally, a high-pass filtering and voltage-divided sampling circuit has been added to ensure the normal operation of the integrator and improve the measurement range of the measurement system. Then, according to the relationship between the amplitude-frequency characteristics of the measurement system and the parameters of each component, the appropriate types of components and op-amp were selected to expand the measurement bandwidth. Finally, a simulation verification was conducted, and the simulation results show that this measurement method can effectively expand the lower measurement frequency limit to 20 Hz, correct the low-frequency distortion caused by Rogowski coils measuring lightning currents on transmission lines, and accurately restore the measured lightning current waveform.
引用
收藏
页数:16
相关论文
共 5 条
  • [1] Self-integrated Rogowski coil for low-frequency high current measurement
    Wei B.
    Qing Y.
    Guan Y.
    Qiu X.
    Fu J.
    Song S.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (09): : 2227 - 2231
  • [2] Differential Reconstruction Method for Power Frequency AC Current Measurement Using Rogowski Coil
    Ibrahim, Mohamed E.
    Abd-Elhady, Amr M.
    IEEE SENSORS JOURNAL, 2016, 16 (23) : 8420 - 8425
  • [3] Current Measurement Technology Based on Rogowski Coil Low Voltage Apparatus
    Lang Fu-cheng
    Zhang Hong-kui
    2017 29TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2017, : 5895 - 5898
  • [4] Measurement of Power Frequency Current including Low- and High-Order Harmonics Using a Rogowski Coil
    El-Shahat, Mohammed
    Eldin, Elsayed Tag
    Mohamed, Nourhan A.
    El-Morshedy, Ahdab
    Ibrahim, Mohamed E.
    SENSORS, 2022, 22 (11)
  • [5] Measurement of Parasitic High-Frequency Currents in Inverter-Fed Low-Speed Electrical Machines Using Rogowski Current Sensors
    Heide, Daniel
    Knebusch, Benjamin
    Ebrahimi, Amir
    Ponick, Bernd
    2021 23RD EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'21 ECCE EUROPE), 2021,