Preliminary Study of a Degenerated Tricuspid Bioprosthetic Valve Implanted via Transcatheter Valve-in-Valve Implantation Guided by 3-Dimensional Printing

被引:0
|
作者
Mao, Yu [1 ]
Ma, Yanyan [1 ]
Zhai, Mengen [1 ]
Li, Lanlan [1 ]
Jin, Ping [1 ]
Liu, Yang [1 ]
Yang, Jian [1 ]
机构
[1] Xijing Hosp, Dept Cardiovasc Surg, Xian, Peoples R China
关键词
REPLACEMENT; OUTCOMES; SURGERY; PROSTHESIS; MANAGEMENT; POSITION; SOCIETY; RISK;
D O I
10.1016/j.cjco.2023.11.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The procedures of transcatheter tricuspid valve-in-valve (TTViV) replacement are challenging, and the clinical outcomes are still unclear. Our goal was to report the short- and mid-term clinical outcomes of patients who underwent a TTViV implantation guided by 3dimensional (3D) printing. Methods: A retrospective analysis was performed on 6 patients who had TTViV implantation from May 2021 to March 2022. The median age was 51 years (range: 18-71 years), and 50.0% of the patients were male. Imaging assessments and 3D printing were performed on all 6 patients before the procedures. The perioperative data were evaluated, and the patients were followed up. Results: Among the 6 patients, the etiologies of conditions affecting the tricuspid valves at baseline varied widely, including 1 case of Ebstein anomaly, 2 cases of infective endocarditis, 1 case of ventricular septal defect, and 2 cases of rheumatic heart disease. TTViV implantation was successfully performed in all 6 patients via the femoral vein approach; postoperative tricuspid regurgitation disappeared immediately, and the hemodynamic results were satisfactory. During the follow-up, all patients had significant fi cant improvement in symptoms and functional status. Conclusions: TTViV implantation for the treatment of degenerated tricuspid bioprostheses should be considered safe and effective. Multimodal imaging and 3D printing may provide effective guidance for conducting the procedure. Clinical Trial Registration: ClinicalTrials.gov Protocol Registration System (NCT02917980).
引用
收藏
页码:978 / 988
页数:11
相关论文
共 50 条
  • [31] Transcatheter Mitral Valve-in-Valve Implantation Applying a Long Pre-Curved Sheath for Patients with Degenerated Bioprosthetic Mitral Valve
    Liu, Yang
    Zhai, Mengen
    Xu, Chennian
    Li, Lanlan
    Mao, Yu
    Ma, Yanyan
    Jin, Ping
    Xue, Wuchao
    Yang, Jian
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2023, 24 (02)
  • [32] Transcatheter valve-in-valve implantation in a degenerated very small Mitroflow prosthesis
    Lopez, Stephane
    Meyer, Pierre
    Teboul, Jacques
    Deharo, Pierre
    Mihoubi, Alain
    Elbeze, Jean Pierre
    Lena, Diane
    Camarasa, Philippe
    Laborde, Jean Claude
    Drogoul, Laurent
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 27 (06) : 850 - 855
  • [33] Percutaneous Transcatheter Valve-in-Valve Implantation With the Balloon-Expandable Valve for the Treatment of a Dysfunctional Tricuspid Bioprosthetic Valve - A Pediatric Case Report
    Hanna, Baher Matta
    Rodes-Cabau, Josep
    Dahdah, Nagib
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (06) : 310 - 312
  • [34] Transcatheter Mitral Valve-in-Valve Implantation With a New Transcatheter Heart Valve for Bioprosthetic Degeneration
    Lu, Yuntao
    Yang, Ye
    Wang, Wenshuo
    Chen, Jinmiao
    Yin, Minyan
    Huang, Liqi
    Dong, Lili
    Wang, Chunsheng
    Wei, Lai
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 8
  • [35] Transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic and mitral valves - an update on indications, techniques, and clinical results
    Gallo, Michele
    Sa, Michel Pompeu B. O.
    Doulamis, Ilias P.
    Hussein, Nabil
    Laforgia, Pietro L.
    Kampaktsis, Polydoros N.
    Tagliari, Ana Paula
    Ferrari, Enrico
    EXPERT REVIEW OF MEDICAL DEVICES, 2021, 18 (07) : 597 - 608
  • [36] Transcatheter Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves
    Gurvitch, Ronen
    Cheung, Anson
    Ye, Jian
    Wood, David A.
    Willson, Alexander B.
    Toggweiler, Stefan
    Binder, Ronald
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) : 2196 - 2209
  • [37] Mitral Valve-in-Valve Implant of a Balloon-Expandable Valve Guided by 3-Dimensional Printing
    Mao, Yu
    Liu, Yang
    Ma, Yanyan
    Jin, Ping
    Li, Lanlan
    Yang, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [38] Transcatheter valve implantation for degenerated tricuspid bioprosthesis and failed tricuspid ring
    Chen, Shmuel
    Dershowitz, Lyle
    George, Isaac
    ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (05) : 651 - +
  • [39] Transcatheter aortic valve implantation for severe regurgitation in native and degenerated bioprosthetic aortic valves
    Sarkar, Kunal
    Sardella, Gennaro
    Romeo, Francesco
    De Benedictis, Mauro
    Tarsia, Giandomenico
    Iadanza, Alessandro
    Sharma, Samin. K.
    Barbanti, Marco
    Tamburino, Corrado
    Ussia, Gian Paolo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 864 - 870
  • [40] The Transcatheter Tricuspid Valve-in-Valve Technique in Degenerated Bioprostheses Without Fluoroscopic Radiopaque Landmarks
    Firouzi, Ata
    Khalilipur, Ehsan
    Abdi, Seifollah
    Alemzadeh-Ansari, Mohammad Javad
    Alizadehasl, Azin
    Khajali, Zahra
    Hosseini, Zahra