Study on nonuniform tip clearance in mixed flow compressor

被引:0
|
作者
Chen, Jixiang [1 ,2 ]
Zhou, Xin [1 ]
Zuo, Zhitao [1 ,2 ,3 ]
Li, Jingxin [1 ]
Tao, Hailiang [1 ]
Chen, Haisheng [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100191, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] R&D Ctr Bijie, Natl Energy Large Scale Phys Energy Storage Techno, Bijie 551712, Peoples R China
基金
中国国家自然科学基金;
关键词
Compressed air energy storage technology; system; Circumferential nonuniform tip clearance; Tip leakage flow; Radial unbalance force; Axial unbalance force; DESIGN; PERFORMANCE; CENTRIFUGAL; BEHAVIOR; STRATEGY;
D O I
10.1016/j.est.2024.113408
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In compressed air energy storage system, the inevitable axial vibration during the frequent start-stop of compressor leads to circumferential nonuniform tip clearance formation, which significantly impacts compressor performance. This paper utilizes numerical simulation to study the overall performance and internal unsteady flow field of a mixed flow compressor with 4 different eccentricities and compares them with the original model. The results indicate that the eccentricity of blade tip clearance has little effect on pressure ratio and isentropic efficiency of the mixed flow compressor, but has an important impact on its stall margin. Specifically, when the eccentricity is 70 % of the blade tip clearance, the compressor stall margin is reduced by 5.96 %. The circumferential distribution of tip relative leakage aligns with the circumferential variation of tip clearance height. The average tip relative leakage increases gradually with the increase of eccentricity, and its growth rate also increases gradually with the increase of eccentricity. There are two peaks and valleys in the radial force distribution of a single blade, while the axial force of a single blade is consistent with the change in circumferential tip clearance height. These findings can provide valuable guidance for subsequent compressor design and operation.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Nonuniform flow in a compressor due to asymmetric tip clearance
    Song, SJ
    Cho, SH
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 751 - 760
  • [2] Prediction of the Nonuniform Tip Clearance Effect on the Axial Compressor Flow Field
    Kang, Young-Seok
    Kang, Shin-Hyoung
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (05): : 0511101 - 0511109
  • [3] Study on tip clearance flow of radial intake mixed flow compressor in CAES system
    Chen, Jixiang
    Zuo, Zhitao
    Zhou, Xin
    Li, Jingxin
    Sun, Jianting
    Xu, Yujie
    Chen, Haisheng
    APPLIED THERMAL ENGINEERING, 2025, 263
  • [4] Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor
    Jung, Yohan
    Choi, Minsuk
    Oh, Seonghwan
    Baek, Jehyun
    INTERNATIONAL JOURNAL OF ROTATING MACHINERY, 2012, 2012
  • [5] Understanding of tip clearance flow structure in high speed mixed flow compressor
    Kumar, Hemant
    Mistry, Chetan S.
    PROPULSION AND POWER RESEARCH, 2023, 12 (03) : 356 - 379
  • [6] Numerical analysis of mixed compressor tip clearance
    Liu, Qiao-Ying
    Yu, Yang
    Tuijin Jishu/Journal of Propulsion Technology, 2013, 34 (02): : 168 - 172
  • [7] Experimental investigations on effects of tip clearance in mixed-flow compressor performance
    Rajakumar, D. Ramesh
    Ramamurthy, S.
    Govardhan, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2015, 229 (05) : 933 - 946
  • [8] NUMERICAL INVESTIGATION OF INFLUENCE OF TIP CLEARANCE IN MIXED-FLOW COMPRESSOR PERFORMANCE
    Zhang, Guo-jie
    Li, Yi-min
    Zhou, Zhong-ning
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2015, 9 (04): : 388 - 394
  • [9] Effect of a Nonuniform Radial/Axial Tip Clearance on the Flow Field in a Mixed-Flow Pump
    Li, W.
    Ji, L. L.
    Shi, W. D.
    Ping, Y. F.
    Zhou, L.
    Jiang, X. P.
    STRENGTH OF MATERIALS, 2018, 50 (01) : 137 - 145
  • [10] Effect of a Nonuniform Radial/Axial Tip Clearance on the Flow Field in a Mixed-Flow Pump
    W. Li
    L. L. Ji
    W. D. Shi
    Y. F. Ping
    L. Zhou
    X. P. Jiang
    Strength of Materials, 2018, 50 : 137 - 145