AFI manual planning versus HyperArc auto-planning: A head-to-head comparison of SRS plan quality

被引:0
作者
Desai, Dharmin D. [1 ]
Cordrey, Ivan L. [2 ]
Johnson, E. Lee [3 ]
Oldland, Thomas A. [3 ]
机构
[1] Varian Med Syst Inc, Adv Oncol Solut, 6402 Harbor Master Dr, Hixson, TN 37343 USA
[2] Cumberland Med Ctr, Thompson Canc Survival Ctr, Crossville, TN USA
[3] Univ Kentucky, Chandler Med Ctr, Dept Radiat Med, Lexington, KY USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 11期
关键词
AFI; HyperArc; plan quality; R50%; SIMT; SRS; RADIOSURGERY; EXPERIENCE;
D O I
10.1002/acm2.14503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: HyperArc (HA) auto-planning offers simplicity for the end user and consistently high-quality SRS plans. The "Ask For It" (AFI) optimization strategy offers a manual planning technique that, when coupled with R50%(Analytic), can be guided to deliver a plan with an intermediate dose spill "as low as reasonably achievable" and high target dose conformity. A direct comparison of SRS plan quality obtained using the manual planning AFI strategy and HA has been performed. Methods: Using a CT data set available from the Radiosurgery Society, 54 PTVs were created and used to generate 19 individual SRS/SRT cases. Case complexity ranged from single PTV plans to multiple PTV plans with a single isocenter. PTV locations ranged from relative isolation from critical structures to lesions within 1.5 mm of the optic apparatus and abutting the brainstem. All cases were planned using both the AFI and HA optimization strategies as implemented in the Varian Medical Systems Eclipse Treatment Planning System. A range of treatment plan quality metrics were obtained including Intermediate Dose Spill (R50%), Conformity Indices CIRTOG and CIPaddick, PTV Dose Coverage (Dn%), PTV Mean Dose, and Modulation Factor. The Wilcoxon Signed Rank Sum non-parametric statistical method was utilized to compare the obtained plan quality metrics. Results: Statistically significant improvements were found for the AFI strategy for metrics R50%, CIRTOG, CIPaddick, and PTV Mean Dose (p < 0.001). HA achieved superior coverage for Dn% (p = 0.018), while the Modulation Factors were not significantly different for AFI compared to HA optimization (p = 0.13). Conclusion: This study provides evidence that the AFI manual planning strategy can produce high-quality planning metrics similar to the HA auto-planning method.
引用
收藏
页数:14
相关论文
共 14 条
[1]   Institutional experience with SRS VMAT planning for multiple cranial metastases [J].
Ballangrud, Ase ;
Kuo, Li Cheng ;
Happersett, Laura ;
Lim, Seng Boh ;
Beal, Kathryn ;
Yamada, Yoshiya ;
Hunt, Margie ;
Mechalakos, James .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02) :176-183
[2]   Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy [J].
Clark, Grant M. ;
Popple, Richard A. ;
Prendergast, Brendan M. ;
Spencer, Sharon A. ;
Thomas, Evan M. ;
Stewart, John G. ;
Guthrie, Barton L. ;
Markert, James M. ;
Fiveash, John B. .
PRACTICAL RADIATION ONCOLOGY, 2012, 2 (04) :306-313
[3]   FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES [J].
Clark, Grant M. ;
Popple, Richard A. ;
Young, P. Edward ;
Fiveash, John B. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01) :296-302
[4]   Analysis of R50% location dependence on LINAC-based VMAT cranial stereotactic treatments [J].
Cordrey, Ivan L. ;
Desai, Dharmin D. ;
Johnson, E. Lee .
MEDICAL DOSIMETRY, 2022, 47 (01) :79-86
[5]   How to estimate R50% for cranial SRS/SRT cases with overlapping 50% isodose volumes: A proposed system [J].
Desai, Dharmin D. ;
Cordrey, Ivan L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (07)
[6]   A measure of SRS/SRT plan quality: Quantitative limits for intermediate dose spill (R50%) in linac-based delivery [J].
Desai, Dharmin D. ;
Cordrey, Ivan L. ;
Johnson, E. L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05)
[7]   Efficient optimization of R50% when planning multiple cranial metastases simultaneously in single isocenter SRS/SRT [J].
Desai, Dharmin D. ;
Cordrey, Ivan L. ;
Johnson, E. L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06) :71-82
[8]   An analytical expression for R50% dependent on PTV surface area and volume: A cranial SRS comparison [J].
Desai, Dharmin D. ;
Johnson, E. L. ;
Cordrey, Ivan L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (02) :203-210
[9]   A clinical application of fair value estimate (FVE) for R50%: Separating overlapping 50% isodose volumes in single isocenter multiple targets SRS [J].
Desai, Dharmin D. D. ;
Cordrey, Ivan L. L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (10)
[10]   Practical Considerations for Single Isocenter LINAC Radiosurgery of Multiple Brain Metastases [J].
Meeks, Sanford L. ;
Mercado, Catherine E. ;
Popple, Richard A. ;
Agazaryan, Nzhde ;
Kaprealian, Tania ;
Fiveash, John B. ;
Tenn, Stephen .
PRACTICAL RADIATION ONCOLOGY, 2022, 12 (03) :195-199