Albuterol Delivery via In-Line Intrapulmonary Percussive Ventilation Superimposed on Invasive Ventilation in an Adult Lung Model

被引:1
作者
Karashima, Takashi [1 ,2 ]
Mimura-Kimura, Yuka [2 ]
Mimura, Yusuke [2 ]
机构
[1] Natl Hosp Org Yamaguchi Ube Med Ctr, Dept Med Engn, Ube, Japan
[2] Natl Hosp Org Yamaguchi Ube Med Ctr, Dept Clin Res, 685 Higashikiwa, Ube 7550241, Japan
关键词
albuterol; drug delivery; intrapulmonary percussive ventilation; mechanical ventilation; MECHANICAL VENTILATION; CONVENTIONAL VENTILATION; NEBULIZER TYPE; TIDAL-VOLUME; AEROSOL; DEPOSITION; JET; POSITION;
D O I
10.4187/respcare.11331
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Intrapulmonary percussive ventilation (IPV) is frequently used for airway clearance, together with delivery of aerosolized medications. Drug delivery via IPV alone increases with decreasing percussion frequency and correlates with tidal volume ( ), whereas drug delivery via IPV during invasive ventilation is not well characterized. We hypothesized that drug delivery via IPV-invasive ventilation would differ from IPV alone due to control of ventilation by invasive ventilation. METHODS: An adult ventilator circuit was used for IPV-invasive ventilation. A normal or a diseased lung model was configured to airway resistance of 5 cm H2O/L/s and lung compliance of 100 mL/cm H2O or to airway resistance of 20 cm H2O/L/s and lung compliance of 50 mL/cm H2O, respectively. The ventilator settings were the following: pressure control continuous mandatory ventilation mode, 10 breaths/min; PEEP, 5 cm H2O; , 0.21; inspiratory time, 1 s; no bias flow; and inspiratory pressure, 10 or 15 cm H2O for the normal or the diseased lung model, respectively, to reach 500 mL with IPV off. Albuterol nebulized from an IPV device was captured in a filter placed before the lung model and quantitated by spectrophotometry. RESULTS: The maximum efficiency of albuterol delivery via IPV-invasive ventilation was not different from that via IPV alone (mean +/- SD of loading dose, 3.7 +/- 0.2% vs 4.2 +/- 0.3%, respectively; P = .12). The mean +/- SD albuterol delivery efficiency with IPV-invasive ventilation was lower for the diseased lung model versus the normal model (1.6 +/- 0.3% vs 3.2 +/- 0.5%; P < .001), which increased with decreasing percussion frequency. In contrast, the mean +/- SD was lower for the normal lung model versus the diseased model (401 +/- 14 mL vs 470 +/- 11 mL; P < .001). CONCLUSIONS: Albuterol delivery via IPV-invasive ventilation was modulated by percussion frequency but was not increased with increasing . The delivery efficiency was not sufficiently high for clinical use, in part due to nebulizer retention and extrapulmonary deposition.
引用
收藏
页码:1092 / 1099
页数:8
相关论文
共 30 条
  • [1] Factors affecting bronchodilator delivery in mechanically ventilated adults
    Ari, Arzu
    Fink, James B.
    [J]. NURSING IN CRITICAL CARE, 2010, 15 (04) : 192 - 203
  • [2] Ari A, 2010, RESP CARE, V55, P845
  • [3] Ari A, 2010, RESP CARE, V55, P837
  • [4] Albuterol Delivery During Invasive Mechanical Ventilation via In-Line Intrapulmonary Percussive Ventilation in a Pediatric Lung Model
    Berlinski, Ariel
    Willis, L. Denise
    [J]. RESPIRATORY CARE, 2024, 69 (01) : 61 - 67
  • [5] Effect of Tidal Volume and Nebulizer Type and Position on Albuterol Delivery in a Pediatric Model of Mechanical Ventilation
    Berlinski, Ariel
    Willis, J. Randy
    [J]. RESPIRATORY CARE, 2015, 60 (10) : 1424 - 1430
  • [6] Albuterol Delivery by 4 Different Nebulizers Placed in 4 Different Positions in a Pediatric Ventilator In Vitro Model
    Berlinski, Ariel
    Willis, J. Randy
    [J]. RESPIRATORY CARE, 2013, 58 (07) : 1124 - 1133
  • [7] Berlinski A, 2010, RESP CARE, V55, P1699
  • [8] RESPIRATORY MECHANICS DURING THE 1ST DAY OF MECHANICAL VENTILATION IN PATIENTS WITH PULMONARY-EDEMA AND CHRONIC AIRWAY-OBSTRUCTION
    BROSEGHINI, C
    BRANDOLESE, R
    POGGI, R
    POLESE, G
    MANZIN, E
    MILICEMILI, J
    ROSSI, A
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 138 (02): : 355 - 361
  • [9] Lung Focused Resuscitation at a Specialized Donor Care Facility Improves Lung Procurement Rates
    Chang, Stephanie H.
    Kreisel, Daniel
    Marklin, Gary F.
    Cook, Lindsey
    Hachem, Ramsey
    Kozower, Benjamin D.
    Balsara, Keki R.
    Bell, Jennifer M.
    Frederiksen, Christine
    Meyers, Bryan F.
    Patterson, G. Alexander
    Puri, Varun
    [J]. ANNALS OF THORACIC SURGERY, 2018, 105 (05) : 1531 - 1536
  • [10] Deakins Kathleen, 2002, Respir Care, V47, P1162