Human relevance of in vivo and in vitro skin irritation tests for hazard classification of pesticides

被引:0
|
作者
Raabe, Hans A. [1 ]
Costin, Gertrude-Emilia [1 ]
Allen, David G. [2 ]
Lowit, Anna [3 ]
Corvaro, Marco [4 ]
O'Dell, Lindsay [3 ]
Breeden-Alemi, Julie [3 ]
Page, Kathryn [5 ]
Perron, Monique [3 ]
Silva, Tara Flint [3 ]
Westerink, Walter [6 ]
Baker, Elizabeth [7 ]
Sullivan, Kristie [1 ]
机构
[1] Inst In Vitro Sci, Gaithersburg, MD 20878 USA
[2] Inotiv, Durham, NC USA
[3] US EPA, Washington, DC USA
[4] Corteva Agrisci, Rome, Italy
[5] Clorox Co, San Francisco, CA USA
[6] Charles River Labs, Den Bosch, Netherlands
[7] Phys Comm Responsible Med, Washington, DC USA
关键词
skin irritation; skin corrosion; new approach methodologies; reconstructed human epidermis; pesticide; formulation; cytokine release; non-animal; RECONSTRUCTED HUMAN EPIDERMIS; PERCUTANEOUS-ABSORPTION; CORROSIVITY TEST; PATCH TEST; MODEL; VALIDATION; INFLAMMATION; MECHANISMS; IL-1-ALPHA; TOXICITY;
D O I
10.1080/15569527.2024.2387596
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Test methods to inform hazard characterization and labeling of pesticides to protect human health are typically conducted using laboratory animals, and for skin irritation/corrosion the rabbit Draize test is currently required by many regulatory agencies. Although the Draize test is generally regarded to provide protective classifications for human health, new approach methodologies (NAMs) have been developed that offer more human relevant models that circumvent the uncertainty associated with species differences that exist between rabbits and humans. Despite wide applicability and use of these test methods across a broad range of chemicals, they have not been widely adopted for testing pesticides and pesticidal formulations. One of the barriers to adoption of these methods in this sector is low concordance with results from the Draize rabbit test, particularly for chemicals within the mild to moderate irritation spectrum.Methods: This review compares and contrasts the extent to which available models used in skin irritation testing mimic the anatomy and physiology of human skin, and how each aligns with the known key events leading to chemically-induced adverse skin irritation and corrosion. Doing so fully characterizes the human relevance of each method.Results: As alternatives to the rabbit Draize test, several protocols using ex vivo, in chemico, and in vitro skin models are available as internationally harmonized test guidelines. These methods rely on a variety of models of human skin, including excised rodent skin, synthetic biochemical models of barrier function, cell culture systems, and reconstructed human tissue models. We find these models exhibit biological and mechanistic relevance aligned with human skin irritation responses. Further, recent retrospective analyses have shown that the reproducibility of the Draize test is less than 50% for mild and moderate responses, with many of the replicate predictions spanning more than one category (e.g., a moderate response reported in one study followed by a non-irritant response reported in another study).Conclusions: Based on this comparative evaluation, we recommend top-down and bottom-up testing strategies that use the most human relevant in vitro test methods for skin irritation and corrosion classification of pesticides and pesticide formulations. To further discriminate among mild and non-irritant formulations, optimization of a cytokine release protocol and subsequent analyses of reference formulation test results is recommended.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 50 条
  • [1] THE IDENTIFICATION AND CLASSIFICATION OF SKIN IRRITATION HAZARD BY A HUMAN PATCH TEST
    BASKETTER, DA
    WHITTLE, E
    GRIFFITHS, HA
    YORK, M
    FOOD AND CHEMICAL TOXICOLOGY, 1994, 32 (08) : 769 - +
  • [2] Risk assessment of the in vitro skin irritation of pesticides using the human skin model
    Kim, Mi-Kyeong
    Jeong, Mihye
    You, Are-Sun
    Hong, Soon-Sung
    Park, Soo-Jin
    Park, Kyung-Hun
    Park, Jae-Eup
    TOXICOLOGY LETTERS, 2012, 211 : S109 - S109
  • [3] Application of an in vitro reconstructed human skin on cosmetics in skin irritation tests
    Ma, Xiao
    Wang, Feifei
    Wang, Bo
    JOURNAL OF COSMETIC DERMATOLOGY, 2021, 20 (06) : 1933 - 1941
  • [4] Quantitative assessment of primary skin irritants in vitro in a cytotoxicity model:: comparison with in vivo human irritation tests
    Wilhelm, KP
    Böttjer, B
    Siegers, CP
    BRITISH JOURNAL OF DERMATOLOGY, 2001, 145 (05) : 709 - 715
  • [5] Prevalidation of in vitro tests for acute skin irritation
    Femtem, J
    Botham, P
    Earl, L
    Roguet, R
    van der Sandt, J
    ALTERNATIVES TO ANIMAL TESTING II, PROCEEDINGS, 1999, : 228 - 231
  • [6] In Vitro Alternatives to Skin-Irritation Tests
    Shin, D. S. et al
    Cosmetics and Toiletries, 1996, 111 (11):
  • [7] INVITRO SKIN IRRITATION ASSAYS - RELEVANCE TO HUMAN SKIN
    HARVELL, J
    BASON, MM
    MAIBACH, HI
    JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1992, 30 (03): : 359 - 369
  • [8] Combined In Vitro Tests as an Alternative to In Vivo Eye Irritation Tests
    Yang Ying
    Yang Xingfen
    Zhang Wengai
    Cai Jinheng
    Xue Jinyu
    Yang Guangyu
    Tan Xiaohua
    Xie Xiaoping
    Xiong Xikun
    Huang Junming
    Guo Xiang
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2010, 38 (04): : 303 - 314
  • [9] In vitro cytotoxicity tests on cultured human skin fibroblasts to predict skin irritation potential of surfactants
    Lee, JK
    Kim, DB
    Kim, JI
    Kim, PY
    TOXICOLOGY IN VITRO, 2000, 14 (04) : 345 - 349
  • [10] In vitro and in vivo assessment of the irritation potential of different spin traps in human skin
    Fuchs, J
    Groth, N
    Herrling, T
    TOXICOLOGY, 2000, 151 (1-3) : 55 - 63