Human Brain Deuterium Metabolic Imaging at 7 T: Impact of Different [6,6′-2H2]Glucose Doses

被引:1
|
作者
Ahmadian, Narjes [1 ]
Konig, Maaike M. [1 ]
Otto, Sigrid [2 ]
Tesselaar, Kiki [2 ]
van Eijsden, Pieter [3 ]
Gosselink, Mark [1 ]
Gursan, Ayhan [1 ]
Klomp, Dennis W. [1 ]
Prompers, Jeanine J. [1 ,4 ]
Wiegers, Evita C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Ctr Image Sci, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, CTI Lab Support, Utrecht, Netherlands
[3] Univ Med Ctr Utrecht, Neurosurg, Utrecht, Netherlands
[4] Maastricht Univ, Med Ctr, NUTRIM Sch Nutr & Translat Res Metab, Human Biol, Maastricht, Netherlands
关键词
deuterium metabolic imaging; 7 T MRI; brain metabolism; GLUCOSE; TURNOVER;
D O I
10.1002/jmri.29532
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Deuterium metabolic imaging (DMI) is an innovative, noninvasive metabolic MR imaging method conducted after administration of H-2-labeled substrates. DMI after [6,6 '-H-2(2)]glucose consumption has been used to investigate brain metabolic processes, but the impact of different [6,6 '-H-2(2)]glucose doses on DMI brain data is not well known. Purpose: To investigate three different [6,6 '-H-2(2)]glucose doses for DMI in the human brain at 7 T. Study Type: Prospective. Population: Six healthy participants (age: 28 +/- 8 years, male/female: 3/3). Field Strength/Sequence: 7 T, 3D H-2 free-induction-decay (FID)-magnetic resonance spectroscopic imaging (MRSI) sequence. Assessment: Three subjects received two different doses (0.25 g/kg, 0.50 g/kg or 0.75 g/kg body weight) of [6,6 '-H-2(2)]glucose on two occasions and underwent consecutive H-2-MRSI scans for 120 minutes. Blood was sampled every 10 minutes during the scan, to determine plasma glucose levels and plasma H-2-Glucose atom percent excess (APE) (part-1). Three subjects underwent the same protocol once after receiving 0.50 g/kg [6,6 '-H-2(2)]glucose (part-2). Statistical Test: Mean plasma H-2-Glucose APE and glucose plasma concentrations were compared using one-way ANOVA. Brain H-2-Glc and brain H-2-Glx (part-1) were analyzed with a two-level Linear Mixed Model. In part-2, a General Linear Model was used to compare brain metabolite signals. Statistical significance was set at P < 0.05. Results: Between 60 and 100 minutes after ingesting [6,6 '-H-2(2)]glucose, plasma H-2-Glc APE did not differ between 0.50 g/kg and 0.75 g/kg doses (P = 0.961), but was significantly lower for 0.25 g/kg. Time and doses significantly affected brain H-2-Glucose levels (estimate +/- standard error [SE]: 0.89 +/- 0.01, 1.09 +/- 0.01, and 1.27 +/- 0.01, for 0.25 g/kg, 0.50 g/kg, and 0.75 g/kg, respectively) and brain H-2-Glutamate/Glutamine levels (estimate +/- SE: 1.91 +/- 0.03, 2.27 +/- 0.03, and 2.46 +/- 0.03, for 0.25 g/kg, 0.50 g/kg, and 0.75 g/kg, respectively). Plasma H-2-Glc APE, brain H-2-Glc, and brain H-2-Glx levels were comparable among subjects receiving 0.50 g/kg [6,6 '-H-2(2)]glucose. Data Conclusion: Brain H-2-Glucose and brain H-2-Glutamate/Glutamine showed to be [6,6 '-H-2(2)]glucose dose dependent. A dose of 0.50 g/kg demonstrated comparable, and well-detectable, H-2-Glucose and H-2-Glutamate/Glutamine signals in the brain. Evidence Level: 1 Technical Efficacy: Stage 2
引用
收藏
页码:1170 / 1178
页数:9
相关论文
共 6 条
  • [1] Deuterium Metabolic Imaging of the Brain Using 2-Deoxy-2-[2H2]-d-glucose: A Non-ionizing [18F]FDG Alternative
    Gao, Xiao
    Qiao, Kai
    Wilson, David M.
    Chaumeil, Myriam M.
    Gordon, Jeremy W.
    JACS AU, 2025, 5 (02): : 571 - 577
  • [2] Deuterium metabolic imaging of the human brain in vivo at 7 T
    Roig, Eulalia Seres
    De Feyter, Henk M.
    Nixon, Terence W.
    Ruhm, Loreen
    Nikulin, Anton, V
    Scheffler, Klaus
    Avdievich, Nikolai, I
    Henning, Anke
    de Graaf, Robin A.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 29 - 39
  • [3] Deuterium Metabolic Imaging of the Brain Using 2-Deoxy-2-[2H2]-<sc>d</sc>-glucose: A Non-ionizing [18F]FDG Alternative
    Gao, Xiao
    Qiao, Kai
    Wilson, David M.
    Chaumeil, Myriam M.
    Gordon, Jeremy W.
    JACS AU, 2025,
  • [4] Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T*
    Niess, Fabian
    Strasser, Bernhard
    Hingerl, Lukas
    Niess, Eva
    Motyka, Stanislav
    Hangel, Gilbert
    Krssak, Martin
    Gruber, Stephan
    Spurny-Dworak, Benjamin
    Trattnig, Siegfried
    Scherer, Thomas
    Lanzenberger, Rupert
    Bogner, Wolfgang
    NEUROIMAGE, 2023, 277
  • [5] Concentric Ring Trajectory Sampling With k-Space Reordering Enables Assessment of Tissue-Specific T1 and T2 Relaxation for 2H-Labeled Substrates in the Human Brain at 7 T
    Bader, Viola
    Strasser, Bernhard
    Bogner, Wolfgang
    Hingerl, Lukas
    Frese, Sabina
    Duguid, Anna
    Osburg, Aaron
    Clarke, William T.
    Motyka, Stanislav
    Krssak, Martin
    Trattnig, Siegfried
    Scherer, Thomas
    Lanzenberger, Rupert
    Niess, Fabian
    NMR IN BIOMEDICINE, 2025, 38 (02)
  • [6] Noninvasive 3-Dimensional 1H-Magnetic Resonance Spectroscopic Imaging of Human Brain Glucose and Neurotransmitter Metabolism Using Deuterium Labeling at 3T Feasibility and Interscanner Reproducibility
    Niess, Fabian
    Hingerl, Lukas
    Strasser, Bernhard
    Bednarik, Petr
    Goranovic, Dario
    Niess, Eva
    Hangel, Gilbert
    Krssak, Martin
    Spurny-Dworak, Benjamin
    Scherer, Thomas
    Lanzenberger, Rupert
    Bogner, Wolfgang
    INVESTIGATIVE RADIOLOGY, 2023, 58 (06) : 431 - 437