Dosimetric Comparison between the HyperArc and Conventional VMAT in Cervical Spine Stereotactic Radiosurgery

被引:0
|
作者
Park, Jeehoon [1 ]
Park, Byungdo [1 ]
Kim, Jeongho [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Changwon Hosp, Sch Med, Dept Radiat Oncol, Chang Won 630522, South Korea
基金
新加坡国家研究基金会;
关键词
HyperArc; cervical spine; stereotactic radiosurgery; stereotactic radiosurgery normal tissue objective; BODY RADIATION-THERAPY; RADIOTHERAPY; IMMOBILIZATION; METASTASES; MOTION; TARGET; HEAD;
D O I
10.3390/jcm13185497
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This research aims to evaluate the usability of the HyperArc (HA) technique in stereotactic radiosurgery for cervical spine metastasis by comparing the dosimetry of the target and organs at risk, specifically the spinal cord, between HA and VMAT and conventional volumetric modulated arc therapy (VMAT). Methods: A RANDO (R) phantom and QFix EncompassTM and support system were used to simulate three target types (A, B, and C) based on RTOG0631 guidelines. Treatment plans included one VMAT and two HyperArc techniques with different SRS NTO values (100 and 250). Dosimetric parameters such as conformity index (CI), homogeneity index (HI), R50, and spinal cord sparing were analyzed. Gamma analysis was performed using portal dosimetry to validate the dose delivery accuracy. Results: HyperArc plans demonstrated higher conformity, sharper dose fall-off, and improved quality assurance (QA) results compared to VMAT plans. HA with SRS NTO 250 showed even better results in terms of conformity, dose fall-off, and spinal cord dose reduction (V10 and Dmax) compared to HA with SRS NTO 100. Although the mean gamma passing rates were slightly lower, all plans achieved rates above 95%. Conclusion: The findings suggest that HA provides superior dosimetric benefits over VMAT and could be effectively utilized for cervical spine radiation therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Spine Instrumentation Failure After Spine Tumor Resection and Radiation: Comparing Conventional Radiotherapy with Stereotactic Radiosurgery Outcomes
    Harel, Ran
    Chao, Samuel
    Krishnaney, Ajit
    Emch, Todd
    Benzel, Edward C.
    Angelov, Lilyana
    WORLD NEUROSURGERY, 2010, 74 (4-5) : 517 - 522
  • [22] IMAGE-GUIDED STEREOTACTIC SPINE RADIOSURGERY ON A CONVENTIONAL LINEAR ACCELERATOR
    Wang, Jia-Zhu
    Rice, Roger
    Mundt, Arno
    Sandhu, Ajay
    Murphy, Kevin
    MEDICAL DOSIMETRY, 2010, 35 (01) : 53 - 62
  • [23] Safety and efficacy of salvage conventional re-irradiation following stereotactic radiosurgery for spine metastases
    Florez, Marcus A.
    De, Brian
    Chapman, Bhavana, V
    Prayongrat, Anussara
    Thomas, Jonathan G.
    Beckham, Thomas H.
    Wang, Chenyang
    Yeboa, Debra N.
    Bishop, Andrew J.
    Briere, Tina
    Amini, Behrang
    Li, Jing
    Tatsui, Claudio E.
    Rhines, Laurence D.
    Ghia, Amol J.
    RADIATION ONCOLOGY JOURNAL, 2023, 41 (01): : 12 - 22
  • [24] Dosimetric comparison between RapidArc and HyperArc in hippocampal-sparing whole-brain radiotherapy with a simultaneous integrated boost
    Kim, Jeongho
    Kim, Tae Gyu
    Park, Byungdo
    Kim, Hyunjung
    Song, Yun Gyu
    Lee, Hyoun Wook
    Kim, Young Zoon
    Ji, Jun Ho
    Kim, Seok-Hyun
    Kim, Sung Min
    Lee, Jun Ho
    Kim, Haeyoung
    MEDICAL DOSIMETRY, 2024, 49 (02) : 76 - 76
  • [25] Dosimetric comparison between two MLC systems commonly used for stereotactic radiosurgery and radiotherapy: A Monte Carlo and experimental study
    Asnaashari, K.
    Chow, James C. L.
    Heydarian, Mostafa
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (04): : 350 - 356
  • [26] Comparison of four techniques for spine stereotactic body radiotherapy: Dosimetric and efficiency analysis
    Aljabab, Saif
    Vellayappan, Balamurugan
    Vandervoort, Eric
    Bahm, Jamie
    Zohr, Robert
    Sinclair, John
    Caudrelier, Jean-Michel
    Szanto, Janos
    Malone, Shawn
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 160 - 167
  • [27] Multiple Brain Metastases Radiosurgery with CyberKnife Device: Dosimetric Comparison between Fixed/Iris and Multileaf Collimator Plans
    Ianiro, Anna
    Infusino, Erminia
    D'Andrea, Marco
    Marucci, Laura
    Farneti, Alessia
    Sperati, Francesca
    Cassano, Bartolomeo
    Ungania, Sara
    Soriani, Antonella
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (02) : 120 - 128
  • [28] DOSIMETRIC COMPARISON OF HELICAL TOMOTHERAPY AND DYNAMIC CONFORMAL ARC THERAPY IN STEREOTACTIC RADIOSURGERY FOR VESTIBULAR SCHWANNOMAS
    Lee, Tsair-Fwu
    Chao, Pei-Ju
    Wang, Chang-Yu
    Lan, Jen-Hong
    Huang, Yu-Je
    Hsu, Hsuan-Chih
    Sung, Chieh-Cheng
    Su, Te-Jen
    Lian, Shi-Long
    Fang, Fu-Min
    MEDICAL DOSIMETRY, 2011, 36 (01) : 62 - 70
  • [29] Cochlear sparing in LINAC-based radiosurgery for vestibular schwannoma: a dosimetric comparison of dynamic conformal arc, IMRT and VMAT treatment plans
    Khong, Jeremy
    Govindaraj, Ramkumar
    Ramm, Daniel
    Edwards, Suzanne
    Roos, Daniel
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [30] Dosimetric comparison of iPlan® Pencil Beam (PB) and Monte Carlo (MC) algorithms in stereotactic radiosurgery/radiotherapy (SRS/SRT) plans of intracranial arteriovenous malformations
    Menon, Sharika Venugopal
    Paramu, Raghukumar
    Bhasi, Saju
    Gopalakrishnan, Zhenia
    Bhaskaran, Sarin
    Nair, Raghuram Kesavan
    MEDICAL DOSIMETRY, 2020, 45 (03) : 225 - 234