Dosimetric Comparison between the HyperArc and Conventional VMAT in Cervical Spine Stereotactic Radiosurgery

被引:0
|
作者
Park, Jeehoon [1 ]
Park, Byungdo [1 ]
Kim, Jeongho [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Changwon Hosp, Sch Med, Dept Radiat Oncol, Chang Won 630522, South Korea
基金
新加坡国家研究基金会;
关键词
HyperArc; cervical spine; stereotactic radiosurgery; stereotactic radiosurgery normal tissue objective; BODY RADIATION-THERAPY; RADIOTHERAPY; IMMOBILIZATION; METASTASES; MOTION; TARGET; HEAD;
D O I
10.3390/jcm13185497
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This research aims to evaluate the usability of the HyperArc (HA) technique in stereotactic radiosurgery for cervical spine metastasis by comparing the dosimetry of the target and organs at risk, specifically the spinal cord, between HA and VMAT and conventional volumetric modulated arc therapy (VMAT). Methods: A RANDO (R) phantom and QFix EncompassTM and support system were used to simulate three target types (A, B, and C) based on RTOG0631 guidelines. Treatment plans included one VMAT and two HyperArc techniques with different SRS NTO values (100 and 250). Dosimetric parameters such as conformity index (CI), homogeneity index (HI), R50, and spinal cord sparing were analyzed. Gamma analysis was performed using portal dosimetry to validate the dose delivery accuracy. Results: HyperArc plans demonstrated higher conformity, sharper dose fall-off, and improved quality assurance (QA) results compared to VMAT plans. HA with SRS NTO 250 showed even better results in terms of conformity, dose fall-off, and spinal cord dose reduction (V10 and Dmax) compared to HA with SRS NTO 100. Although the mean gamma passing rates were slightly lower, all plans achieved rates above 95%. Conclusion: The findings suggest that HA provides superior dosimetric benefits over VMAT and could be effectively utilized for cervical spine radiation therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Hyperarc Vmat and Vmat planning for stereotactic radiosurgery in multiple brain metastases
    Celen, Yonca Yahsi
    Dinc, Ozcan
    Arslan, Nazmiye Deniz
    Dag, Sedef
    Dogan, Ayse Kutluhan
    Gunenc, Senar
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (04)
  • [2] HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
    Ohira, Shingo
    Ueda, Yoshihiro
    Akino, Yuichi
    Hashimoto, Misaki
    Masaoka, Akira
    Hirata, Takero
    Miyazaki, Masayoshi
    Koizumi, Masahiko
    Teshima, Teruki
    RADIATION ONCOLOGY, 2018, 13
  • [3] HyperArc VMAT planning for single and multiple brain metastases stereotactic radiosurgery: a new treatment planning approach
    Shingo Ohira
    Yoshihiro Ueda
    Yuichi Akino
    Misaki Hashimoto
    Akira Masaoka
    Takero Hirata
    Masayoshi Miyazaki
    Masahiko Koizumi
    Teruki Teshima
    Radiation Oncology, 13
  • [4] Dosimetric quality of HyperArc in boost radiotherapy for single glioblastoma: comparison with CyberKnife and manual VMAT
    Pan, Mingyuan
    Xu, Wenqian
    Sun, Lei
    Wang, Chaozhuang
    Dong, Shengnan
    Guan, Yun
    Yang, Jun
    Wang, Enmin
    RADIATION ONCOLOGY, 2023, 18 (01)
  • [5] Feasibility Study of Stereotactic Radiosurgery Treatment of Glomus Jugulare Tumors via HyperArc VMAT
    Pokhrel, Damodar
    Mallory, Richard
    Bush, Matthew
    St Clair, William
    Bernard, Mark E.
    MEDICAL DOSIMETRY, 2022, 47 (04) : 307 - 311
  • [6] Comparison Between Prone and Supine Patient Setup for Spine Stereotactic Body Radiosurgery
    Descovich, Martina
    Ma, Lijun
    Chuang, Cynthia F.
    Larson, David A.
    Barani, Igor J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2012, 11 (03) : 229 - 236
  • [7] Safety and utility of kyphoplasty prior to spine stereotactic radiosurgery for metastatic tumors: a clinical and dosimetric analysis
    Barzilai, Ori
    DiStefano, Natalie
    Lis, Eric
    Yamada, Yoshiya
    Lovelock, D. Michael
    Fontanella, Andrew N.
    Bilsky, Mark H.
    Laufer, Ilya
    JOURNAL OF NEUROSURGERY-SPINE, 2018, 28 (01) : 72 - 78
  • [8] Dosimetric effect of rotational setup errors in stereotactic radiosurgery with HyperArc for single and multiple brain metastases
    Sagawa, Tomohiro
    Ohira, Shingo
    Ueda, Yoshihiro
    Akino, Yuichi
    Mizuno, Hirokazu
    Matsumoto, Masao
    Miyazaki, Masayoshi
    Teshima, Teruki
    Koizumi, Masahiko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (10): : 84 - 91
  • [9] Dosimetric quality of HyperArc in boost radiotherapy for single glioblastoma: comparison with CyberKnife and manual VMAT
    Mingyuan Pan
    Wenqian Xu
    Lei Sun
    Chaozhuang Wang
    Shengnan Dong
    Yun Guan
    Jun Yang
    Enmin Wang
    Radiation Oncology, 18
  • [10] Preliminary dosimetric comparison between fixed and rotating source stereotactic radiosurgery systems
    Draeger, Emily
    Chen, Zhe
    Hansen, James E.
    Chiang, Veronica
    Tien, Christopher J.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):