A heat pump-driven mechanical vapor compression desalination system and its operating characteristics

被引:0
|
作者
Yang, Han [1 ]
Yang, Chunxin [1 ]
Geng, Leiming [2 ]
机构
[1] Beihang Univ, Sch Aeronaut Sci & Engn, Beijing, Peoples R China
[2] AVIC Gen Huanan Aircraft Ind Co Ltd, Zhuhai, Peoples R China
来源
WATER RESOURCES AND INDUSTRY | 2024年 / 32卷
关键词
Mechanical vapor compression (MVC); Desalination; Waste heat utilization; Scaling-endoreversible thermodynamic; analysis model; Operation boundary; HUMIDIFICATION-DEHUMIDIFICATION DESALINATION; THERMODYNAMIC ANALYSIS; WATER DESALINATION; SOLAR; PERFORMANCE; MODEL; UNIT;
D O I
10.1016/j.wri.2024.100264
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The converter valve of ultra-high-voltage direct current grid requires a large amount of cooling water for heat dissipation. Considering the generated waste heat, this study proposes a heat pump-driven mechanical vapor compression (HP-MVC) desalination system based on traditional power-driven mechanical vapor compression (MVC). Using the scaling-endoreversible thermodynamic model, the analytical solutions of the structural equation and operating boundary of the proposed HP-MVC system were derived, which is the innovation of this study. The effects of different component parameters on the thermodynamic characteristics and operation boundaries of the HP-MVC were determined. The results revealed that the HP-MVC system alternately exhibited heat-drive dominant and power-drive dominant modes, in which the specific power consumption was lower in the former. When the recovery ratio was 0.3, with an increase in the pressure ratio from 1.15 to 1.50, the heat supplemented by the heat pump decreased by 31.9 %, and the specific power consumption increased by 63.1 %. The analytical solutions of the structural equation provide a theoretical basis for the efficient operation of the system, and the operation boundaries demonstrate the difference between HP-MVC and traditional MVC. The HPMVC reduces heat dissipation requirements and results in a more energy-efficient desalination system, which is a typical mutually beneficial design and worth promoting.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Enhancing the proficiency of heat pump-driven humidification-dehumidification desalination systems using eco-environmentally friendly organic mixtures
    Hai, Tao
    Chauhan, Bhupendra Singh
    Aksoy, Muammer
    Mahariq, Ibrahim
    Al-Kouz, Wael
    Muhammad, Taseer
    Elmonser, Hedi
    Nhang, Huynh
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2024, 183 : 1117 - 1134
  • [42] Analysis of integrated membrane distillation-heat pump system for water desalination
    Khalifa, Atia
    Mezghani, Ahmed
    Alawami, Hashim
    DESALINATION, 2021, 510
  • [43] Compression heat pump-assisted thermal desalination systems: a comprehensive review
    Mohanraj, M.
    Baimbetov, D.
    Belyayev, Ye
    Kaltayev, A.
    Syrlybekkyzy, S.
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2024, 149 (22) : 12515 - 12575
  • [44] Experimental and theoretical study on a heat pump driven open-air humidification dehumidification desalination system
    Lawal, Dahiru U.
    Jawad, Saad A.
    Antar, Mohamed A.
    ENERGY, 2020, 207
  • [45] Experimental investigations of pump-driven closed-loop thermosyphon system
    Birajdar, Mahasidha R.
    Sewatkar, Chandrasekhar M.
    HEAT TRANSFER, 2022, 51 (08) : 7387 - 7410
  • [46] Experimental investigation of heat pump driven humidification-dehumidification desalination system for water desalination and space conditioning
    Lawal, Dahiru U.
    Antar, Mohamed A.
    Khalifa, Atia
    Zubair, Syed M.
    Al-Sulaiman, Fahad
    DESALINATION, 2020, 475
  • [48] Humidification-dehumidification desalination system operated by a heat pump
    Lawal, Dahiru
    Antar, Mohammed
    Khalifa, Atia
    Zubair, Syed
    Al-Sulaiman, Fahad
    ENERGY CONVERSION AND MANAGEMENT, 2018, 161 : 128 - 140
  • [49] Experimental investigation on a solar assisted heat pump desalination system with humidification-dehumidification
    Xu, H.
    Zhao, Y.
    Jia, T.
    Dai, Y. J.
    DESALINATION, 2018, 437 : 89 - 99
  • [50] Dynamic Simulation and Operating Characteristics of Ground-Coupled Heat Pump with Solar Seasonal Heat Storage System
    Lyu, Chao
    Leong, Wey H.
    Zheng, Maoyu
    Jiang, Ping
    Yu, Feng
    Liu, Yueqin
    HEAT TRANSFER ENGINEERING, 2020, 41 (9-10) : 840 - 850