Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures

被引:2
|
作者
Lemoine, Marc D. [1 ,2 ]
Obergassel, Julius [1 ,2 ]
Jaeckle, Sandro [1 ]
Nies, Moritz [1 ,2 ]
Taraba, Sophia [1 ]
Mencke, Celine [1 ]
Riess, Jan [1 ,2 ]
My, Ilaria [1 ,2 ]
Rottner, Laura [1 ,2 ]
Moser, Fabian [1 ,2 ]
Ismaili, Djemail [1 ,2 ]
Reissmann, Bruno [1 ,2 ]
Ouyang, Feifan [1 ,2 ]
Kirchhof, Paulus [1 ,2 ,3 ]
Rillig, Andreas [1 ,2 ]
Metzner, Andreas [1 ,2 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Univ Heart & Vasc Ctr Hamburg, Dept Cardiol, Hamburg, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site, Hamburg, Germany
[3] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, England
来源
EUROPACE | 2024年 / 26卷 / 09期
基金
英国医学研究理事会;
关键词
Pulsed-field ablation; Cryoballoon; Atrial fibrillation; Pulmonary vein isolation; Reconduction; Repeat ablation; Reisolation; Atrial tachycardia; PAROXYSMAL ATRIAL-FIBRILLATION; 2ND-GENERATION CRYOBALLOON; RADIOFREQUENCY ABLATION; CONTACT-FORCE; OUTCOMES; DURABILITY;
D O I
10.1093/europace/euae221
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Pulsed-field ablation (PFA) is an emerging technology to perform pulmonary vein isolation (PVI). Initial data demonstrated high safety and efficacy. Data on long-term PVI durability and reconduction patterns in comparison to established energy sources for PVI are scarce. We compare findings in repeat ablation procedures after a first PFA to findings in repeat ablation procedures after a first cryoballoon ablation (CBA) based PVI.Methods and result A total of 550 consecutively enrolled patients underwent PFA or CBA index PVI. Repeat ablations in patients with symptomatic atrial arrhythmia recurrences were analysed. A total of 22/191 (12%) patients after index PFA-PVI and 44/359 (12%) after CBA-PVI underwent repeat ablation. Reconduction of any pulmonary vein (PV) was detected by multipolar spiral mapping catheter at each PV with careful evaluation of PV potentials and by 3D-mapping in 16/22 patients (73%) after PFA-PVI and in 33/44 (75%) after CBA-PVI (P = 1.000). Of 82 initially isolated PVs after PFA-PVI, 31 (38%) were reconducting; of 169 isolated PVs after CBA-PVI, 63 (37%) were reconducting (P = 0.936). Clinical atrial tachycardia occurred similarly in patients after PFA (5/22; 23%) and CBA (7/44; 16%; P = 0.515). Roof lines were set more often after PFA- (8/22; 36%) compared with CBA-PVI (5/44; 11%; P = 0.023). Repeat procedure duration [PFA: 87 (76, 123) min; CBA: 93 (75, 128) min; P = 0.446] was similar and fluoroscopy time [PFA: 11 (9, 14) min; CBA: 11 (8, 14) min; P = 0.739] equal between groups at repeat ablation.Conclusion During repeat ablation after previous PFA- or CBA-based PVI, electrical PV-reconduction rates and patterns were similar. Graphical Abstract
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Wide-Band Dielectric Imaging and the Novel Cryoballoon-Occlusion Tool to Guide Cryoballoon-Based Pulmonary Vein Isolation
    Rottner, Laura
    Sinning, Christoph
    Reissmann, Bruno
    Schleberger, Ruben
    Dinshaw, Leon
    Muenkler, Paula
    Meyer, Christian
    Blankenberg, Stefan
    Rillig, Andreas
    Metzner, Andreas
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2020, 13 (08) : E008507
  • [32] Safety and efficacy outcomes of protamine administration for heparin reversal following cryoballoon-based pulmonary vein isolation
    Gurses, Kadri Murat
    Kocyigit, Duygu
    Yalcin, Muhammed Ulvi
    Evranos, Banu
    Yorgun, Hikmet
    Sahiner, Mehmet Levent
    Kaya, Ergun Baris
    Oto, Mehmet Ali
    Ozer, Necla
    Aytemir, Kudret
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2015, 43 (02) : 161 - 167
  • [33] Vagal Reactions during Cryoballoon-Based Pulmonary Vein Isolation: A Clue for Autonomic Nervous System Modulation?
    Peyrol, Michael
    Barraud, Jeremie
    Koutbi, Linda
    Maille, Baptiste
    Trevisan, Lory
    Martinez, Elisa
    Levy, Samuel
    Paganelli, Franck
    Franceschi, Frederic
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [34] Safety and efficacy outcomes of protamine administration for heparin reversal following cryoballoon-based pulmonary vein isolation
    Kadri Murat Gurses
    Duygu Kocyigit
    Muhammed Ulvi Yalcin
    Banu Evranos
    Hikmet Yorgun
    Mehmet Levent Sahiner
    Ergun Baris Kaya
    Mehmet Ali Oto
    Necla Ozer
    Kudret Aytemir
    Journal of Interventional Cardiac Electrophysiology, 2015, 43 : 161 - 167
  • [35] First-line catheter ablation of paroxysmal atrial fibrillation: outcome of radiofrequency vs. cryoballoon pulmonary vein isolation
    Straube, Florian
    Dorwarth, Uwe
    Ammar-Busch, Sonia
    Peter, Timo
    Noelker, Georg
    Massa, Thomas
    Kuniss, Malte
    Ewertsen, Niels Christian
    Chun, Kyoung Ryul Julian
    Tebbenjohanns, Juergen
    Tilz, Roland
    Kuck, Karl Heinz
    Ouarrak, Taoufik
    Senges, Jochen
    Hoffmann, Ellen
    EUROPACE, 2016, 18 (03): : 368 - 375
  • [36] Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures
    Ciconte, Giuseppe
    Velagic, Vedran
    Mugnai, Giacomo
    Saitoh, Yukio
    Irfan, Ghazala
    Hunuk, Burak
    Stroker, Erwin
    Conte, Giulio
    Sieira, Juan
    Di Giovanni, Giacomo
    Baltogiannis, Giannis
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    EUROPACE, 2016, 18 (01): : 71 - 77
  • [37] Pulsed field ablation and cryoballoon ablation for pulmonary vein isolation: insights on efficacy, safety and cardiac function
    Rattka, Manuel
    Mavrakis, Evangelos
    Vlachopoulou, Dimitra
    Rudolph, Isabel
    Kohn, Christina
    Bohnen, Jan
    Yahsaly, Loubna
    Siebermair, Johannes
    Wakili, Reza
    Jungen, Christiane
    Rassaf, Tienush
    Mathew, Shibu
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (05) : 1191 - 1198
  • [38] Impact of overweight and obesity on radiation dose and outcome in patients undergoing pulmonary vein isolation by cryoballoon and pulsed field ablation
    Jungen, Christiane
    Rattka, Manuel
    Bohnen, Jan
    Mavrakis, Evangelos
    Vlachopoulou, Dimitra
    Dorna, Sebastian
    Rudolph, Isabel
    Kohn, Christina
    Dobrev, Dobromir
    Rassaf, Tienush
    Mathew, Shibu
    IJC HEART & VASCULATURE, 2024, 55
  • [39] Immediate and medium-term outcomes of cryoballoon-based pulmonary vein isolation in patients with paroxysmal and persistent atrial fibrillation: single-centre experience
    Kudret Aytemir
    Ali Oto
    Uğur Canpolat
    Hamza Sunman
    Hikmet Yorgun
    Levent Şahiner
    Ergün Barış Kaya
    Journal of Interventional Cardiac Electrophysiology, 2013, 38 : 187 - 195
  • [40] Long-term Outcomes of Cryoballoon-based Empirical Superior Vena Cava Isolation in Addition to Pulmonary Vein Isolation in Persistent Atrial Fibrillation
    Canpolat, Ugur
    Yorgun, Hikmet
    Aytemir, Kudret
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2024, 28 (09) : 437 - 445