Impact of Oxidative Chemicals on Hydrophobic Porous Membranes Used in Membrane Distillation

被引:3
作者
Cairney, Hannah T. [1 ]
Hjelvik, Elizabeth A. [2 ]
Straub, Anthony P. [1 ,2 ]
机构
[1] Univ Colorado Boulder, Dept Civil Architectural & Environm Engn, Boulder, CO 80309 USA
[2] Univ Colorado Boulder, Dept Mat Sci & Engn, Boulder, CO 80309 USA
来源
ACS APPLIED ENGINEERING MATERIALS | 2024年 / 2卷 / 04期
基金
美国国家科学基金会;
关键词
membrane distillation; chlorine; ozone; desalination; hydrophobicmembrane; WASTE-WATER; POLY(VINYLIDENE FLUORIDE); CHLORAMINE SPECIATION; CHLORINE; PVDF; OSMOSIS; POLYPROPYLENE; DEGRADATION; MECHANISMS; STABILITY;
D O I
10.1021/acsaenm.4c00152
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Direct treatment of water purification membranes with strong oxidative chemicals, such as ozone and chlorine, is a promising avenue to prevent fouling and improve the water treatment performance. In this work, we investigate the oxidation resistance of hydrophobic polymers commonly used in membrane distillation by probing the impact of ozone and chlorine exposure on the membrane structure, chemistry, and desalination performance. To probe oxidative behavior, polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), and polypropylene (PP) membranes were exposed to sodium hypochlorite (10,000 ppm, pH 4) and ozone (15 ppm, pH 7) solutions for up to 72 and 3 h, respectively. We then characterized the membrane samples using Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), water contact angle measurements, and desalination performance testing. Our results indicate that PTFE membranes show no chemical, structural, or desalination performance changes after exposure to the highest doses of chlorine and ozone, with only minor decreases in the water contact angle (less than 15%) after exposure to oxidants. PVDF also showed no observable changes in structure or performance, although XPS analysis indicated possible defluorination of the surface after oxidant exposure. PP membranes showed the most severe degradation, with surface cracking, chemical changes, and complete failure in desalination testing after exposure to 10,000 ppm chlorine for 1 h or 15 ppm ozone for 30 min. Measurements of salt rejection and water flux of the pristine and oxidized membranes showed greater than 99.9% rejection and minimal changes in water flux regardless of oxidant or exposure length, except in the case of PP which showed failure during testing. Our results provide insights into the degradation behavior of hydrophobic polymer membranes and demonstrate the promise of using PTFE and PVDF membranes combined with strong oxidants in water treatment.
引用
收藏
页码:1162 / 1169
页数:8
相关论文
共 50 条
[1]   Hydrophobic polyethersulfone porous membranes for membrane distillation [J].
Heba Abdallah ;
Ayman El-Gendi ;
Maaly Khedr ;
Elham El-Zanati .
Frontiers of Chemical Science and Engineering, 2015, 9 :84-93
[2]   Hydrophobic polyethersulfone porous membranes for membrane distillation [J].
Abdallah, Heba ;
El-Gendi, Ayman ;
Khedr, Maaly ;
El-Zanati, Elham .
FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2015, 9 (01) :84-93
[3]   Porous hydrophobic-hydrophilic composite membranes for direct contact membrane distillation [J].
Puranik, Aishwarya A. ;
Rodrigues, Lydia N. ;
Chau, John ;
Li, Lin ;
Sirkar, Kamalesh K. .
JOURNAL OF MEMBRANE SCIENCE, 2019, 591
[4]   Characterisation of three hydrophobic porous membranes used in membrane distillation -: Modelling and evaluation of their water vapour permeabilities [J].
Martínez, L ;
Florido-Díaz, FJ ;
Hernández, A ;
Prádanos, P .
JOURNAL OF MEMBRANE SCIENCE, 2002, 203 (1-2) :15-27
[5]   Preparation of hydrophobic PVDF hollow fiber membranes for desalination through membrane distillation [J].
Hou, Deyin ;
Wang, Jun ;
Qu, Dan ;
Luan, Zhaokun ;
Zhao, Changwei ;
Ren, Xiaojing .
WATER SCIENCE AND TECHNOLOGY, 2009, 59 (06) :1219-1226
[6]   Capillary Polypropylene Membranes for Membrane Distillation [J].
Gryta, Marek .
FIBERS, 2019, 7 (01)
[7]   A new method for permeability measurement of hydrophobic membranes used in Membrane Distillation [J].
Dao, T. D. ;
Mericq, J. P. ;
Laborie, S. ;
Cabassud, C. .
EUROMEMBRANE CONFERENCE 2012, 2012, 44 :1221-1222
[8]   Properties and membrane distillation performance of polypropylene porous membranes [J].
Bottino, A. ;
Capannelli, G. ;
Comiti, A. ;
Costa, C. ;
Mescola, A. ;
Calvo, J. I. .
EUROMEMBRANE CONFERENCE 2012, 2012, 44 :1216-1218
[9]   A review on the manufacturing techniques of porous hydrophobic ceramic membranes applied to direct contact membrane distillation [J].
Morais Ferreira, Roberta Karoline ;
Ramlow, Heloisa ;
Marangoni, Cintia ;
Francisco Machado, Ricardo Antonio .
ADVANCES IN APPLIED CERAMICS, 2021, 120 (5-8) :336-357
[10]   CHARACTERIZATION OF HYDROPHOBIC POLYMERIC MEMBRANES FOR MEMBRANE DISTILLATION PROCESS [J].
Mannella, G. A. ;
La Carrubba, V. ;
Brucato, V. .
INTERNATIONAL JOURNAL OF MATERIAL FORMING, 2010, 3 :563-566