Curved Toroidal Row Column Addressed Transducer for 3D Ultrafast Ultrasound Imaging

被引:6
作者
Caudoux, Manon [1 ]
Demeulenaere, Oscar [1 ]
Poree, Jonathan [1 ]
Sauvage, Jack [1 ]
Mateo, Philippe [1 ]
Ghaleh, Bijan [2 ]
Flesch, Martin [3 ]
Ferin, Guillaume
Tanter, Mickael [1 ]
Deffieux, Thomas [1 ]
Papadacci, Clement [1 ]
Pernot, Mathieu [1 ]
机构
[1] PSL Univ, INSERM, CNRS, Phys Med,ESPCI, F-75015 Paris, France
[2] Ecole Natl Veterinaire Alfort, Inserm, UPEC, U955,IMRB, F-94700 Maisons Alfort, France
[3] Vermon, F-37000 Tours, France
关键词
Imaging; Probes; Transducers; Three-dimensional displays; Ultrasonic imaging; Heart; Apertures; 4D ultrafast imaging; row-column addressing; toroidal curved transducer; ultrasound localization microscopy; SUPERRESOLUTION; RESOLUTION; DOPPLER; ARRAYS;
D O I
10.1109/TMI.2024.3391689
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
3D Imaging of the human heart at high frame rate is of major interest for various clinical applications. Electronic complexity and cost has prevented the dissemination of 3D ultrafast imaging into the clinic. Row column addressed (RCA) transducers provide volumetric imaging at ultrafast frame rate by using a low electronic channel count, but current models are ill-suited for transthoracic cardiac imaging due to field-of-view limitations. In this study, we proposed a mechanically curved RCA with an aperture adapted for transthoracic cardiac imaging ( $24\times16$ mm2). The RCA has a toroidal curved surface of 96 elements along columns (curvature radius rC = 4.47 cm) and 64 elements along rows (curvature radius rR = 3 cm). We implemented delay and sum beamforming with an analytical calculation of the propagation of a toroidal wave which was validated using simulations (Field II). The imaging performance was evaluated on a calibrated phantom. Experimental 3D imaging was achieved up to 12 cm deep with a total angular aperture of 30 degrees for both lateral dimensions. The Contrast-to-Noise ratio increased by 12 dB from 2 to 128 virtual sources. Then, 3D Ultrasound Localization Microscopy (ULM) was characterized in a sub-wavelength tube diameter. Finally, 3D ULM was demonstrated on a perfused ex-vivo swine heart to image the coronary microcirculation.
引用
收藏
页码:3279 / 3291
页数:13
相关论文
共 49 条
[41]   High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation [J].
Poree, Jonathan ;
Posada, Daniel ;
Hodzic, Amir ;
Tournoux, Francois ;
Cloutier, Guy ;
Garcia, Damien .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (07) :1647-1657
[42]   3D ultrafast ultrasound imaging in vivo [J].
Provost, Jean ;
Papadacci, Clement ;
Arango, Juan Esteban ;
Imbault, Marion ;
Fink, Mathias ;
Gennisson, Jean-Luc ;
Tanter, Mickael ;
Pernot, Mathieu .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19) :L1-L13
[43]   3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study [J].
Rasmussen, Morten Fischer ;
Jensen, Jorgen Arendt .
2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, :1452-1455
[44]   3D ultrasound imaging performance of a row-column addressed 2D array transducer: a simulation study [J].
Rasmussen, Morten Fischer ;
Jensen, Jorgen Arendt .
MEDICAL IMAGING 2013: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2013, 8675
[45]   A large aperture row column addressed probe for in vivo 4D ultrafast doppler ultrasound imaging [J].
Sauvage, J. ;
Flesch, M. ;
Ferin, G. ;
Nguyen-Dinh, A. ;
Poree, J. ;
Tanter, M. ;
Pernot, M. ;
Deffieux, T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (21)
[46]   4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array [J].
Sauvage, Jack ;
Poree, Jonathan ;
Rabut, Claire ;
Ferin, Guillaume ;
Flesch, Martin ;
Rosinski, Bogdan ;
An Nguyen-Dinh ;
Tanter, Mickael ;
Pernot, Mathieu ;
Deffieux, Thomas .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) :1884-1893
[47]   Improved Super-Resolution Ultrasound Microvessel Imaging With Spatiotemporal Nonlocal Means Filtering and Bipartite Graph-Based Microbubble Tracking [J].
Song, Pengfei ;
Trzasko, Joshua D. ;
Manduca, Armando ;
Huang, Runqing ;
Kadirvel, Ramanathan ;
Kallmes, David F. ;
Chen, Shigao .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (02) :149-167
[48]   In vivo 3D Super-Resolution Ultrasound Imaging of a Rat Kidney using a Row-Column Array [J].
Taghavi, Iman ;
Schou, Mikkel ;
Panduro, Nathalie Sarup ;
Andersen, Sofie Bech ;
Tomov, Borislav G. ;
Sorensen, Charlotte Mehlin ;
Stuart, Matthias Bo ;
Jensen, Jorgen Arendt .
2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
[49]   A Review of Clinical Applications for Super-resolution Ultrasound Localization Microscopy [J].
Yi, Hui-ming ;
Lowerison, Matthew R. ;
Song, Peng-fei ;
Zhang, Wei .