Hybrid calibration method for a single camera stereo digital image correlation system

被引:0
|
作者
Qian, Siwei [1 ,2 ]
Liang, Junzhe [3 ]
Liang, Jin [1 ]
Ren, Maodong [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
[2] XTOP 3D Technol Shenzhen Co Ltd, Innovat Lab, Shenzhen 518060, Guangdong, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Microelect, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
24;
D O I
10.1364/AO.524730
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In single camera stereo digital image correlation systems, the existing calibration methods have problems with poor accuracy and violation of theoretical constraints, so we have proposed a hybrid calibration method. In this study, we first explain the principles of the existing single camera stereo measurement calibration methods. Then, on the basis of the classical camera calibration method combined with the characteristics of planar mirror reflection imaging, a hybrid calibration method is proposed that not only satisfies the constraints of the same intrinsic parameters but also has higher accuracy. Next, we complete the mathematical model of the hybrid calibration method and explain the specific calibration process. Finally, the experimental results of point distance reconstruction and static displacement measurement show that, compared with the existing calibration methods, the hybrid calibration method has lower error and higher reconstruction accuracy. (c) 2024 Optica Publishing Group
引用
收藏
页码:5099 / 5106
页数:8
相关论文
共 50 条
  • [21] A single-image linear calibration method for camera
    Zhang, Zhuang
    Zhao, Rujin
    Liu, Enhai
    Yan, Kun
    Ma, Yuebo
    MEASUREMENT, 2018, 130 : 298 - 305
  • [22] Effect of camera temperature variations on stereo-digital image correlation measurements
    Pan, Bing
    Shi, Wentao
    Lubineau, Gilles
    APPLIED OPTICS, 2015, 54 (34) : 10089 - 10095
  • [23] Calibration error for dual-camera digital image correlation at microscale
    Li, Kai
    Wang, Qiang
    Wu, Jia
    Yu, Haiyang
    Zhang, Dongsheng
    OPTICS AND LASERS IN ENGINEERING, 2012, 50 (07) : 971 - 975
  • [24] A single-camera telecentric imaging stereo-digital image correlation system and its application to carotid pulse signal detection
    Chen, Chao
    Tang, Xiaojun
    Pan, Bing
    STRAIN, 2024, 60 (03)
  • [25] Using camera calibration to apply digital image correlation outside the laboratory
    Liang, Zhenning
    Yin, Bo
    Dai, Xin
    Mo, Jinqiu
    Wang, Shigang
    OPTICAL ENGINEERING, 2013, 52 (12)
  • [26] Ultraviolet Single-Camera Stereo-Digital Image Correlation for Deformation Measurement up to 2600 °C
    Luo, Y. X.
    Dong, Y. L.
    Yang, F. Q.
    Lu, X. Y.
    EXPERIMENTAL MECHANICS, 2024, 64 (08) : 1343 - 1355
  • [27] Multi-perspective digital image correlation method using a single color camera
    YongHong Wang
    XiZuo Dan
    JunRui Li
    SiJin Wu
    LianXiang Yang
    Science China Technological Sciences, 2018, 61 : 61 - 67
  • [28] Multi-perspective digital image correlation method using a single color camera
    WANG YongHong
    DAN XiZuo
    LI JunRui
    WU SiJin
    YANG LianXiang
    Science China(Technological Sciences), 2018, 61 (01) : 61 - 67
  • [29] Multi-perspective digital image correlation method using a single color camera
    Wang YongHong
    Dan XiZuo
    Li JunRui
    Wu SiJin
    Yang LianXiang
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2018, 61 (01) : 61 - 67
  • [30] Multi-perspective digital image correlation method using a single color camera
    WANG YongHong
    DAN XiZuo
    LI JunRui
    WU SiJin
    YANG LianXiang
    Science China(Technological Sciences) , 2018, (01) : 61 - 67