摘要
Liquid carbon dioxide (CO2) energy storage is a promising technology for balancing grid supply and demand, but liquefaction in high temperature environments is a substantial dilemma. In this study, a novel liquid CO2 mixture energy storage system coupled with a coal-fired power plant is proposed to broaden the liquefiable ambient temperature range, where condensate and feedwater without phase change are used for compression heat recovery and CO2 mixture heating. Firstly, eight refrigerant additives are selected to blend with CO2; then, comparative performance analysis between CO2 mixtures and pure CO2 is conducted, followed by parametric studies; finally, a double-layer decision-making framework based on multi-objective optimization is adopted for additive screening across various ambient temperatures. The results show that a moderate amount of additive favors system safety but degrades thermodynamics and economy, well at high temperatures the performance of CO2 mixture improves and absolutely outperforms pure CO2. CO2/difluoromethane (CO2/R32) reduces the system operating pressure by 20.95 % over pure CO2 at ambient temperature of 298.15 K, accompanied by only 5.78 %, 0.76 % and 9.92 % deterioration in round-trip efficiency, energy storage density and levelized cost of electricity, and exhibits optimal adaptation to varying additive mass fraction. The working fluid unit cost and heat exchangers are the main factors causing these variances. In response to environmental changes, CO2/pro- pylene (CO2/R1270) and CO2/R32 emerge as the two most adaptable mixtures, with the former preferred at low ambient temperatures (288.15-293.15 K) and the latter at high ambient temperatures (298.15-308.15 K). Among all additives, R600 and R161 consistently rank lowest in priority regardless of ambient temperature.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Performance evaluation and analysis of a coal-fired power plant coupled with a liquid carbon dioxide energy storage system
    Zheng, Lixing
    Li, Sijia
    Shi, Tongtong
    Xue, Xiaojun
    Xu, Gang
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [2] Thermodynamic performance and economic analysis of coupled a liquid carbon dioxide energy storage system in a coal-fired power plant
    Han, Xu
    He, Peiliang
    Liu, Zhongwen
    Sun, Chunqi
    Wang, Xiaodong
    JOURNAL OF ENERGY STORAGE, 2024, 99
  • [3] Performance analysis of a liquid carbon dioxide energy storage system integrated with a coal-fired power plant
    Hou, Kun
    Wang, Yan
    Han, Ningze
    Ma, Tingshan
    Lv, Kai
    Liu, Xiangyang
    He, Maogang
    JOURNAL OF ENERGY STORAGE, 2024, 77
  • [4] Study on the thermodynamic performance of a coupled compressed air energy storage system in a coal-fired power plant
    Yan, Xiaosheng
    Wang, Xiaodong
    Han, Xu
    Sun, Chunqi
    Li, Peng
    Han, Zhonghe
    JOURNAL OF ENERGY STORAGE, 2023, 68
  • [5] Performance analysis of a compressed air energy storage system integrated into a coal-fired power plant
    Zhang, Lei
    Cui, Jie
    Zhang, Yanping
    Yang, Tao
    Li, Jianlan
    Gao, Wei
    ENERGY CONVERSION AND MANAGEMENT, 2020, 225
  • [6] Performance study of 660 MW coal-fired power plant coupled transcritical carbon dioxide energy storage cycle: Sensitivity and dynamic characteristic analysis
    Wang, Di
    Zhou, Yu
    Si, Long
    Sun, Lingfang
    Zhou, Yunlong
    ENERGY, 2024, 293
  • [7] Study on the peak shaving performance of coupled system of compressed air energy storage and coal-fired power plant
    Gong, Liangyong
    Li, Yanghai
    Wang, Yuanjing
    Zhang, Yanping
    JOURNAL OF ENERGY STORAGE, 2025, 107
  • [8] Design and Performance Analysis of Main Steam Coupled with Electric Heating Molten Salt Energy Storage System for Coal-Fired Power Plant
    Yu, Libin
    Li, Wenjun
    Zheng, Chenghang
    Zhao, Zhongyang
    Wang, Yifan
    Dang, Qi
    Yang, Xudong
    2024 IEEE 2ND INTERNATIONAL CONFERENCE ON POWER SCIENCE AND TECHNOLOGY, ICPST 2024, 2024, : 1405 - 1410
  • [9] Thermodynamic analysis and operation strategy optimization of coupled molten salt energy storage system for coal-fired power plant
    Li, Bo
    Cao, Yue
    He, Tianyu
    Si, Fengqi
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [10] Performance analysis of tower solar aided coal-fired power plant with thermal energy storage
    Jiang, Yue
    Duan, Liqiang
    Yang, Ming
    Tong, Yongjing
    Pang, Liping
    APPLIED THERMAL ENGINEERING, 2022, 206