Energy-Function Based Pilot Protection Scheme for Hybrid UHVDC Transmission Applying Improved Hausdorff Distance

被引:0
|
作者
Wang, Zijiang [1 ,2 ]
Fan, Youping [1 ,2 ]
Shang, Ben [1 ,2 ]
Shu, Yinbiao [1 ,2 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Inst Next Generat Power Syst & Int Stand, Wuhan 430072, Peoples R China
来源
关键词
Energy function; Hausdorff distance; pilot protection; UHVDC transmission; POWER-SYSTEM; HVDC; CONVERTER;
D O I
10.17775/CSEEJPES.2022.01330
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A hybrid UHVDC transmission system applying LCC as the rectifier and MMC as the inverter combines the advantages of both converter types, which makes this protection scheme more complicated. A new pilot protection scheme for a three-terminal hybrid DC transmission system applying energy functions is proposed. The energy function for LCC is applied to MMC to derive the energy level of the hybrid system. Furthermore, an improved Hausdorff distance (IHD) algorithm is proposed to detect the difference in energy levels between the normal and fault states. An abrupt change in energy level is characterized by IHD change rate. Time points at which the IHD change rate exceeds the threshold at converter stations are applied to determine the fault line and to estimate the fault section. The proposed protection scheme is then verified by a simulation model of the Wudongde +/- 800 kV three-terminal hybrid UHVDC transmission project. The appropriate sampling frequency is selected for a real-time calculation, and the threshold is selected considering the effect of noise. Results show the proposed scheme can identify and trip fault lines quickly and effectively, even for a 600 Omega grounding fault. Other waveshape similarity algorithms are compared and analyzed. Compared with existing protection schemes, the proposed scheme transmits less data to improve communication speed and reliability.
引用
收藏
页码:891 / 902
页数:12
相关论文
共 50 条
  • [1] Improved Differential Protection Scheme for Long Distance UHVDC Transmission Line
    Zheng, Xiaodong
    Tai, Nengling
    Thorp, James S.
    Yang, Xia
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [2] Improved scheme for differential protection of UHVDC transmission lines
    Xia J.-D.
    Luo J.-Y.
    Gao S.-P.
    Jiao Z.-B.
    Shao W.-Q.
    Huang X.-B.
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2019, 53 (03): : 579 - 588
  • [3] Distance protection scheme with travelling wave for UHVDC transmission line based on wavelet transform
    long, Chen Shi
    Chun, Shu Hong
    zhi, Wang Yong
    Fang, Zeng
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2162 - 2165
  • [4] Improved Hausdorff Distance Based Pilot Protection for Multi-terminal HVDC system
    Huai, Qing
    Qin, Liang
    Liu, Kaipei
    Xu, Yi
    Wang, Fangzhou
    Ding, Hua
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (04) : 1955 - 1969
  • [5] Improved Hausdorff Distance Based Pilot Protection for Multi-terminal HVDC system
    Qing Huai
    Liang Qin
    Kaipei Liu
    Yi Xu
    Fangzhou Wang
    Hua Ding
    Journal of Electrical Engineering & Technology, 2021, 16 : 1955 - 1969
  • [6] Self-adaptive differential protection scheme for transmission line based on Hausdorff distance algorithm
    Li Y.
    Wu Z.
    Wang F.
    Zeng G.
    Chen Z.
    Luo Y.
    Zhu X.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (07): : 175 - 180and187
  • [7] Adaptability Analysis of Pilot Differential Protection for Hybrid Cascaded UHVDC Transmission Lines
    Mu D.
    Lin S.
    Li X.
    Dianwang Jishu/Power System Technology, 2024, 48 (05): : 2170 - 2178
  • [8] A massive data reduction scheme based on improved hausdorff distance
    Nie, Shuzhi
    Ye, Bangyan
    International Journal of Applied Mathematics and Statistics, 2013, 51 (23): : 106 - 114
  • [9] A pilot protection scheme for HVDC transmission lines based on boundary energy
    Yang, Yayu
    Tai, Nengling
    Liu, Jian
    Zheng, Xiaodong
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (22): : 5757 - 5767
  • [10] Improved Euclidean Distance Based Pilot Protection for Lines With Renewable Energy Sources
    Yang, Zhe
    Liao, Wenlong
    Wang, Hongyi
    Bak, Claus Leth
    Chen, Zhe
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2022, 18 (12) : 8551 - 8562