Synchronized Diabetes Monitoring System: Development of Smart Mobile Apparatus for Diabetes Using Insulin

被引:0
作者
Kahraman, Mustafa [1 ,2 ]
Dudukcu, Hatice Vildan [3 ]
Kurt, Serkan [3 ]
Yildiz, Huseyin [4 ]
Aydin, Nizamettin [5 ]
Mutlu, Ummu [6 ]
Cakmak, Ramazan [6 ]
Boz, Elif Beyza [7 ]
Ozbek, Hasan Ediz [7 ]
Erturk, Mehmet Ali [8 ]
Ozogur, Gokhan [9 ]
Ozogur, Hatice Nizam [9 ]
Aydin, Muhammed Ali [9 ]
Karsidag, Kubilay [6 ]
Ozturk, Sukru [10 ]
Satman, Ilhan [6 ]
Karan, Mehmet Akif [11 ]
机构
[1] TUSEB Turkey Inst Publ Hlth & Chron Dis, Istanbul, Turkiye
[2] Istanbul Univ, Istanbul Fac Med, Dept Physiol, Istanbul, Turkiye
[3] Yildiz Tech Univ, Dept Elect & Commun Engn, Istanbul, Turkiye
[4] Istanbul Univ Cerrahpasa, Dept Mech & Met Technol, Istanbul, Turkiye
[5] Yildiz Tech Univ, Dept Comp Engn, Istanbul, Turkiye
[6] Istanbul Univ, Istanbul Fac Med, Dept Internal Med, Div Endocrine & Metab Dis, Istanbul, Turkiye
[7] Istanbul Univ, Istanbul Fac Med, Istanbul, Turkiye
[8] Istanbul Univ, Sch Transportat & Logist, Dept Transportat & Logist, Istanbul, Turkiye
[9] Istanbul Univ Cerrahpasa, Dept Comp Engn, Istanbul, Turkiye
[10] Istanbul Univ, Istanbul Fac Med, Dept Internal Med, Istanbul, Turkiye
[11] Istanbul Univ, Istanbul Fac Med, Dept Internal Med, Div Geriatr, Istanbul, Turkiye
关键词
SMA helps users to control blood sugar; Diabetes mellitus; Wearable health technologies; Patient monitoring; Insulin dose tracking; Smart mobile apparatus; DOSE-MEMORY; PEN;
D O I
10.1016/j.irbm.2024.100852
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate and timely injection of insulin doses in accordance with the treatment protocol is very important in the follow-up of insulin-dependent diabetes patients. In this study, a new smart mobile apparatus (SMA) has been developed. The SMA can be attached to insulin pens and record and transfer data by detecting the patient's dose of insulin and the time at which it was provided. The SMA can detect the dose determined in the insulin pen through linear capacitive sensors. Electronic parts and sensor mechanism are located on the designed SMA body. The insulin pen's two-part mechanical construction of the body senses movement during dosage adjustment while also making sure the dose information is recorded in the control unit. The dose and time information recorded in the SMA internal memory are transmitted to the patient's smartphone via the developed mobile application. The developed SMA prototypes were evaluated by a team of doctors in a hospital setting for three months. As a result of the three-month study, it was observed that the insulin dose and administration times could be accurately sent to the smartphone application via SMA. The SMA was created in the laboratory environment and was prepared for pilot research with insulin-dependent diabetes patients in a hospital setting. It was observed that the SMA prototype successfully identified and recorded the dose and timing of the patient's self-administered insulin. (c) 2024 AGBM. Published by Elsevier Masson SAS. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
引用
收藏
页数:7
相关论文
共 18 条
  • [1] Dave V., 2013, International Journal of Advances in Pharmaceutical Sciences, V4, P01
  • [2] Gildon Bradford W, 2018, Diabetes Spectr, V31, P354, DOI 10.2337/ds18-0011
  • [3] Insulclock: A Novel Insulin Delivery Optimization and Tracking System
    Gomez-Peralta, Fernando
    Abreu, Cristina
    Gomez-Rodriguez, Sara
    Ruiz, Luis
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (04) : 209 - 214
  • [4] THE EFFECT OF MEDICAL DEVICES WITH DOSE-MEMORY AND REMINDER FUNCTIONS ON PATIENTS' TREATMENT ADHERENCE, CONFIDENCE AND DISEASE SELF-MANAGEMENT
    Hall, R.
    Harald-Kongso, J.
    Humphrey, L.
    Willgoss, T.
    [J]. VALUE IN HEALTH, 2013, 16 (07) : A336 - A336
  • [5] The effect of medical device dose-memory functions on patients' adherence to treatment, confidence, and disease self-management
    Hall, Rebecca L.
    Willgoss, Thomas
    Humphrey, Louise J.
    Kongso, Jens Harald
    [J]. PATIENT PREFERENCE AND ADHERENCE, 2014, 8 : 775 - 788
  • [6] NovoPen Echo (R) insulin delivery device
    Hyllested-Winge, Jacob
    Sparre, Thomas
    Pedersen, Line Kynemund
    [J]. MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2016, 9 : 11 - 18
  • [7] HumaPen® Memoir™:: a novel insulin-injecting pen with a dose-memory feature
    Ignaut, Debra A.
    Venekamp, Willem J. R. R.
    [J]. EXPERT REVIEW OF MEDICAL DEVICES, 2007, 4 (06) : 793 - 802
  • [8] Pediatric Smart Insulin Pen Use: The Next Best Thing
    Ilkowitz, Jeniece
    Wissing, Vanessa
    Gallagher, Mary Pat
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (03): : 635 - 640
  • [9] 'Smart' insulin-delivery technologies and intrinsic glucose-responsive insulin analogues
    Jarosinski, Mark A.
    Dhayalan, Balamurugan
    Rege, Nischay
    Chatterjee, Deepak
    Weiss, Michael A.
    [J]. DIABETOLOGIA, 2021, 64 (05) : 1016 - 1029
  • [10] Kahraman M, 2019, TPE patent, Patent No. [TR201601577b, 201601577]