Evaluation of the effect of ocular dominance on macular microcirculation via swept-source optical coherence tomography angiography

被引:1
作者
Karakucuk, Yalcin [1 ]
Eker, Serhat [1 ]
机构
[1] Isparta Yalvac State Hosp, Dept Ophthalmol, Hidirlik Mevkii Sht Latif Kececi Sk, TR-32400 Isparta, Turkiye
关键词
Ocular dominance; Dominant eye; Interocular difference; Vascular density; Macular perfusion; Swept-source optical coherence tomography; angiography; EYE; PARAMETERS;
D O I
10.1016/j.pdpdt.2024.104317
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the existence of differences in the retinal microcirculation of dominant and non-dominant eyes, as well as of interocular differences in macular microcirculation, using swept-source optical coherence tomography angiography (OCTA). Methods: In total, 122 eyes of 61 individuals were enrolled in this cross-sectional study. Measurements were taken using the swept-source optical coherence tomography Triton device (Topcon Corp, Tokyo, Japan) coupled with non-invasive OCTA technology. Macular perfusion parameters were assessed, including superficial vascular complex, vascular density of the deep vascular complex, vascular density of the choriocapillaris vascular complex, superficial foveal avascular zone and deep foveal avascular zone. Ocular dominance was determined among individuals with healthy eyes using the hole-in-the-card test. Results: Ocular dominance was found in 68.9 % of right eyes and 31.1 % of left eyes. The mean age of the subjects was 34.45 +/- 16.48 years (range: 18-73 years). We found that 16 (30.76 %) males and 22 (31.42 %) females had left-eye dominance (p > 0.05). None of the OCTA parameters differed between the eyes based on dominance (p > 0.05). Central macular thickness and sub-foveal choroidal thickness did not show significant differences (p > 0.05). When comparing interocular parameters, a significant difference was observed only in the inferior sector of the superficial vascular complex (p = 0.04). Conclusion: There was no significant difference in OCTA parameters between dominant and non-dominant eyes. There was no predominant interocular difference in the measurements.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Cataract significantly influences quantitative measurements on swept-source optical coherence tomography angiography imaging
    Yu, Siqing
    Frueh, Beatrice E.
    Steinmair, Dagmar
    Ebneter, Andreas
    Wolf, Sebastian
    Zinkernagel, Martin S.
    Munk, Marion R.
    PLOS ONE, 2018, 13 (10):
  • [22] Choroidal Changes in Carotid Stenosis Patients After Stenting Detected by Swept-source Optical Coherence Tomography Angiography
    Wan, Jincheng
    Kwapong, William Robert
    Tao, Wendan
    Lu, Kun
    Jiang, Shuai
    Zheng, Hongbo
    Hu, Fayun
    Wu, Bo
    CURRENT NEUROVASCULAR RESEARCH, 2022, 19 (01) : 100 - 107
  • [23] Evaluation of the Cortical Vitreous Using Swept-Source Optical Coherence Tomography in Normal Eyes
    Park, Seung Hun
    Lee, Jung Wook
    Lee, Min Ji
    Lee, Ju Hyang
    Song, In Seok
    Lee, Byung Ro
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (04): : 595 - 600
  • [24] SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY DETECTION OF BRUCH MEMBRANE AND CHORIOCAPILLARIS ABNORMALITIES IN SORSBY MACULAR DYSTROPHY
    Iyer, Prashanth G.
    Zhou, Hao
    Zhang, Qinqin
    Chu, Zhongdi
    Shen, Mengxi
    Shi, Yingying
    Liu, Jeremy
    Trivizki, Omer
    Lam, Byron L.
    Wang, Ruikang K.
    Gregori, Giovanni
    Rosenfeld, Philip J.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (09): : 1645 - 1654
  • [25] DURATION OF PRONE POSITIONING AFTER MACULAR HOLE SURGERY DETERMINED BY SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Sano, Masahiko
    Inoue, Makoto
    Itoh, Yuji
    Kita, Yoshiyuki
    Hirota, Kazunari
    Koto, Takashi
    Hirakata, Akito
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (08): : 1483 - 1491
  • [26] Are choriocapillaris flow void features robust to diurnal variations? A swept-source optical coherence tomography angiography (OCTA) study
    Lin, Emily
    Ke, Mengyuan
    Tan, Bingyao
    Yao, Xinwen
    Wong, Damon
    Ong, Lirong
    Schmetterer, Leopold
    Chua, Jacqueline
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [27] Detection of dental carious lesions by swept-source optical coherence tomography
    Zhan, Zhenlin
    Fang, Yuhong
    Wang, Guangxing
    Xie, Shusen
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820
  • [28] Effect of Hemodialysis on Peripapillary Choroidal Thickness Measured by Swept-Source Optical Coherence Tomography
    Lee, Won June
    Hong, Rimkyung
    Kang, Min Ho
    Cho, Heeyoon
    Han, Sang-Woong
    Yi, Joo-Hark
    Shin, Yong Un
    Seong, Mincheol
    JOURNAL OF GLAUCOMA, 2021, 30 (06) : 459 - 464
  • [29] Subgingival calculus imaging based on swept-source optical coherence tomography
    Hsieh, Yao-Sheng
    Ho, Yi-Ching
    Lee, Shyh-Yuan
    Lu, Chih-Wei
    Jiang, Cho-Pei
    Chuang, Ching-Cheng
    Wang, Chun-Yang
    Sun, Chia-Wei
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (07)
  • [30] Evaluation of retinal and choroidal thickness changes in overweight and obese adults without ocular symptoms by swept-source optical coherence tomography
    Li, Qing-Jian
    Zhou, Sheng-Mei
    Zhang, Ling -Yu
    Lin, An-Ni
    Zhang, Yang
    Jiang, Jing
    Che, Xin
    Qian, Yi-Wen
    Liu, Yan
    Wang, Zhi-Liang
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2024, 17 (04) : 707 - 712