Use of ultra-low contrast dose CT aortography for the management of aortic aneurysmal disease

被引:2
作者
Borkowski, Philip [3 ]
Ng, Eugene [1 ]
Vicaretti, Mauro [2 ,3 ]
Young, Noel [1 ,3 ]
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW 2145, Australia
[2] Westmead Hosp, Dept Vasc Surg, Sydney, NSW 2145, Australia
[3] Univ Sydney, Discipline Med, Sydney, NSW 2006, Australia
关键词
Contrast; Dose; Computed tomography; Aortography; Aneurysmal disease; Aortogram; Aortic aneurysm; EVAR (endovascular aneurysm repair); ABDOMINAL-AORTA; IMAGE QUALITY; FOLLOW-UP; ANGIOGRAPHY; REPAIR; VOLUME;
D O I
10.1186/s13019-024-03099-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeComputed tomography aortography (CTA) is used in the assessment of aortic pathologies and planning of surgical intervention. However, its dependence on iodinated contrast can result in development of contrast-induced acute kidney injury (CI-AKI). The potential concern of CI-AKI has spurred research into the potential of administration of low contrast volumes in CTA investigations while maintaining overall diagnostic appeal. Several studies have shown that CTA using contrast volumes as low as 30 mL (equivalent to 10.5 g of iodine) can still yield scans of diagnostic quality. We present a retrospective pilot study to evaluate the feasibility of utilising an ultra-low volume of iodinated intravenous contrast in a population of patients with severe renal insufficiency with referral from our vascular surgery unit for CTA evaluation of the thoracic and abdominal aorta.MethodsThis retrospective pilot study examined 12 CTA scans performed with 20 mLs of iodinated contrast and assessed image quality with both quantitative and qualitative markers. All scans were performed on a Siemens SOMATOM Force dual-source CT scanner. Quantitative assessment values were measured via attenuation values at eight aortoiliac locations and used to calculate a signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at each location. Qualitative analysis of image quality and viability for surgical intervention was obtained from subjective clinical assessment by an interventional radiologist and vascular surgeon.ResultsObtained quantitative assessment values included mean attenuation 189.9 HU, mean SNR 9.6 and mean CNR 8.0. All 12 scans demonstrated individual mean SNR values above predetermined quality thresholds while only five scans produced individual mean CNR values above threshold. Eleven of 12 scans were determined to be of sufficient quality for diagnosis and planning of surgical intervention.ConclusionsOur results suggest that CTA utilising an ultra-low contrast dose of 20 mLs (6 g iodine) yields scans of diagnostic quality for therapeutic decision-making in vascular surgical intervention.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] The use of ultra-low-dose CT scans for the evaluation of limb fractures
    Konda, S. R.
    Goch, A. M.
    Leucht, P.
    Christiano, A.
    Gyftopoulos, S.
    Yoeli, G.
    Egol, K. A.
    BONE & JOINT JOURNAL, 2016, 98B (12) : 1668 - 1673
  • [42] Ultra Low Dose CT Pulmonary Angiography with Iterative Reconstruction
    Sauter, Andreas
    Koehler, Thomas
    Fingerle, Alexander A.
    Brendel, Bernhard
    Richter, Vivien
    Rasper, Michael
    Rummeny, Ernst J.
    Noel, Peter B.
    Muenzel, Daniela
    PLOS ONE, 2016, 11 (09):
  • [43] Contemporary use of and outcomes associated with ultra-low contrast volume in patients undergoing percutaneous coronary interventions
    Gurm, Hitinder S.
    Seth, Milan
    Dixon, Simon R.
    Grossman, P. Michael
    Sukul, Devraj
    Lalonde, Thomas
    Cannon, Louis
    West, Daniel
    Madder, Ryan D.
    Lauver, D. Adam
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2019, 93 (02) : 222 - 230
  • [44] Optimization of paranasal sinus CT procedure: Ultra-low dose CT as a roadmap for pre-functional endoscopic sinus surgery
    Diklic, Ana
    Zujic, Petra Valkovic
    Segota, Doris
    Debeljuh, Dea Dundara
    Jurkovic, Slaven
    Brambilla, Marco
    Kalra, Mannudeep K.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 195 - 200
  • [45] Evaluation of AI-Based Segmentation Tools for COVID-19 Lung Lesions on Conventional and Ultra-low Dose CT Scans
    Aiello, Marco
    Baldi, Dario
    Esposito, Giuseppina
    Valentino, Marika
    Randon, Marco
    Salvatore, Marco
    Cavaliere, Carlo
    DOSE-RESPONSE, 2022, 20 (01):
  • [46] Ultra-Low Radiation Dose and Contrast Medium of Coronary CT Angiography Using Prospectively ECG-Triggered Without Heart Rate Control: A New Strategy
    Zhao, Lei
    Yang, Xiaoguang
    Hao, Fen'e
    Cao, Peng
    Lv, Tiegang
    Wang, Zefeng
    Yang, Zhenxing
    Sun, Zhenting
    Meng, Lingxin
    Liu, Aishi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2017, 7 (08) : 1863 - 1869
  • [47] Consistent low-contrast detectability for variable patient sizes and corresponding dose in abdominal CT
    Zhou, Yifang
    Nute, Jessica
    Scott, Alexander, II
    Lee, Christina
    MEDICAL PHYSICS, 2017, 44 (03) : 861 - 872
  • [48] Low-contrast-dose protocol in cardiac CT: 20% contrast dose reduction using 100 kVp and high-tube-current-time setting in 256-slice CT
    Kidoh, Masafumi
    Nakaura, Takeshi
    Nakamura, Shinichi
    Nakamura, Shota
    Sakaino, Naritsugu
    Harada, Kazunori
    Uemura, Shouzaburou
    Yamashita, Yasuyuki
    ACTA RADIOLOGICA, 2014, 55 (05) : 545 - 553
  • [49] Can low-dose CT with iterative reconstruction reduce both the radiation dose and the amount of iodine contrast medium in a dynamic CT study of the liver?
    Takahashi, Hiroto
    Okada, Masahiro
    Hyodo, Tomoko
    Hidaka, Syojiro
    Kagawa, Yuki
    Matsuki, Mitsuru
    Tsurusaki, Masakatsu
    Murakami, Takamichi
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (04) : 684 - 691
  • [50] Assessment of pancreatic adenocarcinoma: Use of low-dose whole pancreatic CT perfusion and individualized dual-energy CT scanning
    Li, Hai-ou
    Guo, Jun
    Sun, Cong
    Li, Xiao
    Qi, Yao-dong
    Wang, Xi-ming
    Xu, Zhuo-dong
    Chen, Jiu-hong
    Liu, Cheng
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (05) : 590 - 598