Use of ultra-low contrast dose CT aortography for the management of aortic aneurysmal disease

被引:2
作者
Borkowski, Philip [3 ]
Ng, Eugene [1 ]
Vicaretti, Mauro [2 ,3 ]
Young, Noel [1 ,3 ]
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW 2145, Australia
[2] Westmead Hosp, Dept Vasc Surg, Sydney, NSW 2145, Australia
[3] Univ Sydney, Discipline Med, Sydney, NSW 2006, Australia
关键词
Contrast; Dose; Computed tomography; Aortography; Aneurysmal disease; Aortogram; Aortic aneurysm; EVAR (endovascular aneurysm repair); ABDOMINAL-AORTA; IMAGE QUALITY; FOLLOW-UP; ANGIOGRAPHY; REPAIR; VOLUME;
D O I
10.1186/s13019-024-03099-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeComputed tomography aortography (CTA) is used in the assessment of aortic pathologies and planning of surgical intervention. However, its dependence on iodinated contrast can result in development of contrast-induced acute kidney injury (CI-AKI). The potential concern of CI-AKI has spurred research into the potential of administration of low contrast volumes in CTA investigations while maintaining overall diagnostic appeal. Several studies have shown that CTA using contrast volumes as low as 30 mL (equivalent to 10.5 g of iodine) can still yield scans of diagnostic quality. We present a retrospective pilot study to evaluate the feasibility of utilising an ultra-low volume of iodinated intravenous contrast in a population of patients with severe renal insufficiency with referral from our vascular surgery unit for CTA evaluation of the thoracic and abdominal aorta.MethodsThis retrospective pilot study examined 12 CTA scans performed with 20 mLs of iodinated contrast and assessed image quality with both quantitative and qualitative markers. All scans were performed on a Siemens SOMATOM Force dual-source CT scanner. Quantitative assessment values were measured via attenuation values at eight aortoiliac locations and used to calculate a signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at each location. Qualitative analysis of image quality and viability for surgical intervention was obtained from subjective clinical assessment by an interventional radiologist and vascular surgeon.ResultsObtained quantitative assessment values included mean attenuation 189.9 HU, mean SNR 9.6 and mean CNR 8.0. All 12 scans demonstrated individual mean SNR values above predetermined quality thresholds while only five scans produced individual mean CNR values above threshold. Eleven of 12 scans were determined to be of sufficient quality for diagnosis and planning of surgical intervention.ConclusionsOur results suggest that CTA utilising an ultra-low contrast dose of 20 mLs (6 g iodine) yields scans of diagnostic quality for therapeutic decision-making in vascular surgical intervention.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Diagnostic Accuracy of Low and Ultra-Low Dose CT for Identification of Urinary Tract Stones: A Systematic Review
    Rodger, Flora
    Roditi, Giles
    Aboumarzouk, Omar M.
    UROLOGIA INTERNATIONALIS, 2018, 100 (04) : 375 - 385
  • [22] Multiple Adversarial Learning Based Angiography Reconstruction for Ultra-Low-Dose Contrast Medium CT
    Zhang, Weiwei
    Zhou, Zhen
    Gao, Zhifan
    Yang, Guang
    Xu, Lei
    Wu, Weiwen
    Zhang, Heye
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (01) : 409 - 420
  • [23] Ultra-Low Contrast Computed Tomographic Angiography (CTA) With 20-mL Total Dose for Transcatheter Aortic Valve Implantation (TAVI) Planning
    Azzalini, Lorenzo
    Abbara, Suhny
    Ghoshhajra, Brian B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 105 - 109
  • [24] 16-MDCT aortography with a low-dose contrast material protocol
    Utsunomiya, D
    Awai, K
    Tamura, Y
    Nishiharu, T
    Urata, J
    Sakamoto, T
    Taniguchi, A
    Yamashita, Y
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) : 374 - 378
  • [25] Ultra-low dose contrast CT pulmonary angiography in oncology patients using a high-pitch helical dual-source technology
    Rajiah, Prabhakar
    Ciancibello, Leslie
    Novak, Ronald
    Sposato, Jennifer
    Landeras, Luis
    Gilkeson, Robert
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2019, 25 (03) : 195 - 203
  • [26] Iterative reconstruction in single-source dual-energy CT angiography: feasibility of low and ultra-low volume contrast medium protocols
    Hou, Ping
    Feng, Xiangnan
    Liu, Jie
    Zhou, Yue
    Jiang, Yaojun
    Jiang, Xiaochen
    Gao, Jianbo
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1075)
  • [27] Whole-body ultra-low dose CT using spectral shaping for detection of osteolytic lesion in multiple myeloma
    Suntharalingam, Saravanabavaan
    Mikat, Christian
    Wetter, Axel
    Guberina, Nika
    Salem, Ahmed
    Heil, Philipp
    Forsting, Michael
    Nassenstein, Kai
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2273 - 2280
  • [28] Comparison of conventional chest x ray with a novel projection technique for ultra-low dose CT
    Carey, Sean
    Kandel, Sonja
    Farrell, Christin
    Kavanagh, John
    Chung, TaeBong
    Hamilton, William
    Rogalla, Patrik
    MEDICAL PHYSICS, 2021, 48 (06) : 2809 - 2815
  • [29] In vitro accuracy of ultra-low dose cone-beam CT for detection of proximal caries
    Taeby, Aria
    Seyyedi, Seyyed Amir
    Mostafavi, Maryam
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07) : 459 - 467
  • [30] Ultra-Low-Dose Neck CT With Low-Dose Contrast Material for Preoperative Staging of Thyroid Cancer: Image Quality and Diagnostic Performance
    Yeom, Jeong A.
    Roh, Jieun
    Jeong, Yeon Joo
    Lee, Jin Choon
    Kim, Hyun Yul
    Suh, Young Ju
    Baik, Seung Kug
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (04) : 748 - 754