Use of ultra-low contrast dose CT aortography for the management of aortic aneurysmal disease

被引:2
作者
Borkowski, Philip [3 ]
Ng, Eugene [1 ]
Vicaretti, Mauro [2 ,3 ]
Young, Noel [1 ,3 ]
机构
[1] Westmead Hosp, Dept Radiol, Sydney, NSW 2145, Australia
[2] Westmead Hosp, Dept Vasc Surg, Sydney, NSW 2145, Australia
[3] Univ Sydney, Discipline Med, Sydney, NSW 2006, Australia
关键词
Contrast; Dose; Computed tomography; Aortography; Aneurysmal disease; Aortogram; Aortic aneurysm; EVAR (endovascular aneurysm repair); ABDOMINAL-AORTA; IMAGE QUALITY; FOLLOW-UP; ANGIOGRAPHY; REPAIR; VOLUME;
D O I
10.1186/s13019-024-03099-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PurposeComputed tomography aortography (CTA) is used in the assessment of aortic pathologies and planning of surgical intervention. However, its dependence on iodinated contrast can result in development of contrast-induced acute kidney injury (CI-AKI). The potential concern of CI-AKI has spurred research into the potential of administration of low contrast volumes in CTA investigations while maintaining overall diagnostic appeal. Several studies have shown that CTA using contrast volumes as low as 30 mL (equivalent to 10.5 g of iodine) can still yield scans of diagnostic quality. We present a retrospective pilot study to evaluate the feasibility of utilising an ultra-low volume of iodinated intravenous contrast in a population of patients with severe renal insufficiency with referral from our vascular surgery unit for CTA evaluation of the thoracic and abdominal aorta.MethodsThis retrospective pilot study examined 12 CTA scans performed with 20 mLs of iodinated contrast and assessed image quality with both quantitative and qualitative markers. All scans were performed on a Siemens SOMATOM Force dual-source CT scanner. Quantitative assessment values were measured via attenuation values at eight aortoiliac locations and used to calculate a signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) at each location. Qualitative analysis of image quality and viability for surgical intervention was obtained from subjective clinical assessment by an interventional radiologist and vascular surgeon.ResultsObtained quantitative assessment values included mean attenuation 189.9 HU, mean SNR 9.6 and mean CNR 8.0. All 12 scans demonstrated individual mean SNR values above predetermined quality thresholds while only five scans produced individual mean CNR values above threshold. Eleven of 12 scans were determined to be of sufficient quality for diagnosis and planning of surgical intervention.ConclusionsOur results suggest that CTA utilising an ultra-low contrast dose of 20 mLs (6 g iodine) yields scans of diagnostic quality for therapeutic decision-making in vascular surgical intervention.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Ultra-low dose chest CT: The end of chest radiograph?
    Ludes, Claire
    Schaal, Marysa
    Labani, Aissam
    Jeung, Mi-Young
    Roy, Catherine
    Ohana, Mickael
    PRESSE MEDICALE, 2016, 45 (03): : 291 - 301
  • [2] Ultra-low dose CT scanning for PET/CT
    Mostafapour, Samaneh
    Greuter, Marcel
    van Snick, Johannes H.
    Brouwers, Adrienne H.
    Dierckx, Rudi A. J. O.
    van Sluis, Joyce
    Lammertsma, Adriaan A.
    Tsoumpas, Charalampos
    MEDICAL PHYSICS, 2024, 51 (01) : 139 - 155
  • [3] Detectability of Lung Nodules in Ultra-low Dose CT
    Janssen, Sonja
    Overhoff, Daniel
    Froelich, Matthias F.
    Schoenberg, Stefan O.
    Rathmann, Nils
    ANTICANCER RESEARCH, 2021, 41 (10) : 5053 - 5058
  • [4] Limits of Ultra-Low Dose CT Attenuation Correction for PET/CT
    Xia, Ting
    Alessio, Adam M.
    Kinahan, Paul E.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3074 - 3079
  • [5] Low Tube Voltage and Iterative Model Reconstruction in Follow-up CT Angiography After Thoracic Endovascular Aortic Repair: Ultra-low Radiation Exposure and Contrast Medium Dose
    Hou, Ping
    Feng, Xiangnan
    Liu, Jie
    Wang, Xiaopeng
    Jiang, Yaojun
    Dong, Leigang
    Gao, Jianbo
    ACADEMIC RADIOLOGY, 2018, 25 (04) : 494 - 501
  • [6] Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results
    Bodelle, B.
    Wichmann, J. L.
    Klotz, N.
    Lehnert, T.
    Vogl, T. J.
    Luboldt, W.
    Schulz, B.
    CLINICAL RADIOLOGY, 2015, 70 (07) : 711 - 715
  • [7] Lung nodules assessment in ultra-low-dose CT with iterative reconstruction compared to conventional dose CT
    Jin, Shiqi
    Zhang, Bo
    Zhang, Lina
    Li, Shu
    Li, Songbai
    Li, Peiling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (05) : 480 - 490
  • [8] Ultra-low radiation dose CT angiography of the lower extremity using the iterative model reconstruction (IMR) algorithm
    Qian, W-L.
    Zhou, D. -J.
    Jiang, Y.
    Feng, C.
    Chen, Q.
    Wang, H.
    Zhang, J. -B.
    Xu, J. -M.
    CLINICAL RADIOLOGY, 2018, 73 (11) : 985.e13 - 985.e19
  • [9] Ultra-low Dose Lung CT Perfusion Regularized by a Previous Scan
    Yu, Hengyong
    Zhao, Shiying
    Hoffman, Eric A.
    Wang, Ge
    ACADEMIC RADIOLOGY, 2009, 16 (03) : 363 - 373
  • [10] Submillisievert standard-pitch CT pulmonary angiography with ultra-low dose contrast media administration: A comparison to standard CT imaging
    Suntharalingam, Saravanabavaan
    Mikat, Christian
    Stenzel, Elena
    Erfanian, Youssef
    Wetter, Axel
    Schlosser, Thomas
    Forsting, Michael
    Nassenstein, Kai
    PLOS ONE, 2017, 12 (10):