Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol

被引:0
|
作者
Tam, Dang Thi Minh [1 ]
Ho, Phan Long [2 ,3 ,4 ]
Uy, Phan Quoc [1 ,2 ,3 ]
Hieu, Nguyen Trung [1 ]
Linh, Vo Tan [1 ]
Hoa, Nguyen Thi [1 ]
Lam, Nguyen Thi The [1 ]
Nga, Bui Thi Thuy [1 ]
Thanh, Truong Huu [1 ]
Thanh, Tran Thien [2 ,3 ]
Tao, Chau Van [2 ,3 ]
机构
[1] Ho Chi Minh Oncol Hosp, Dept Radiol Technol, Ho Chi Minh, Vietnam
[2] Univ Sci, Fac Phys & Engn Phys, Dept Nucl Phys, 227,Nguyen Van Cu St,Dist 5, Ho Chi Minh, Vietnam
[3] Vietnam Natl Univ, Ho Chi Minh, Vietnam
[4] Inst Publ Hlth Ho Chi Minh City, Ho Chi Minh, Vietnam
关键词
IMRT; VMAT; TG; 119; protocol; TrueBeam linac; Semiflex ion chamber; EPID; Quality assurance; IMRT; VERIFICATION; RADIOTHERAPY; IRRADIATION; CARCINOMA; SYSTEM; VMAT;
D O I
10.1007/s00411-024-01091-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this work was to evaluate the conformity of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), and verify the accuracy of the planning and delivery system used in this work based on the AAPM TG-119 protocol. The Eclipse 13.6 treatment planning system (TPS) was used to plan the TG-119 test suite, which included four test cases: MultiTarget, Prostate, Head/Neck, and C-Shape for IMRT and VMAT techniques with 6 MV and 10 MV acceleration voltages. The results were assessed and discussed in terms of the TG-119 protocol and the results of previous studies. In addition, point dose and planar dose measurements were done using a semiflex ion chamber and an electronic portal imaging device (EPID), respectively. The planned doses of all test cases met the criteria of the TG-119 protocol, except those for the spinal cord of the C-Shape hard case. There were no significant differences between the treatment planning doses and the doses given in the TG-119 report, with p-values ranging from 0.974 to 1 (p > 0.05). Doses to the target volumes were similar in the IMRT and VMAT plans, but the organs at risk (OARs) doses were different depending on the test case. The planning results showed that IMRT is more conformal than VMAT in certain cases. For the point dose measurements, the confidence limit (CLpoint) of 0.030 and 0.021 were better than the corresponding values of 0.045 and 0.047 given in the TG-119 report for high-dose and low-dose areas, respectively. Regarding the planar dose measurements, the CLplanar value of 0.38 obtained in this work was lower than that given in the TG-119 report (12.4). It is concluded that the dosimetry measurements performed in this study showed better confidence limits than those provided in the TG 119 report. IMRT remains more conformal in certain circumstances than the more progressive VMAT. When selecting the method of delivering a dose to the patient, several factors must be considered, including the radiotherapy technique, energy, treatment site, and tumour geometry.
引用
收藏
页码:557 / 571
页数:15
相关论文
共 50 条
  • [41] Multi-institutional comparison of computer-based independent dose calculation for intensity modulated radiation therapy and volumetric modulated arc therapy
    Kamima, Tatsuya
    Baba, Hiromi
    Takahashi, Ryo
    Yamashita, Mikiko
    Sugawara, Yasuharu
    Kawai, Daisuke
    Yamamoto, Toshijiro
    Satou, Aya
    Tachibana, Hidenobu
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 72 - 81
  • [42] Effect of dose grid resolution on the results of patient-specific quality assurance for intensity-modulated radiation therapy and volumetric modulated arc therapy
    Chun, M.
    Kim, J., I
    Oh, G. H.
    Wu, H. G.
    Park, J. M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 18 (03): : 521 - 530
  • [43] Intensity-modulated radiation therapy versus volumetric-modulated arc therapy in non-small cell lung cancer: assessing the risk of radiation pneumonitis
    Rosas, Sara
    Barbosa, Barbara
    Couto, Jose G.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (01) : 6 - 11
  • [44] Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy
    Chi, Alexander
    Lin, Lien-Chun
    Wen, Sijin
    Yan, Haijuan
    Hsi, Wen-Chien
    RADIATION ONCOLOGY, 2017, 12
  • [45] Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy
    Alexander Chi
    Lien-Chun Lin
    Sijin Wen
    Haijuan Yan
    Wen-Chien Hsi
    Radiation Oncology, 12
  • [46] Dosimetric analysis of testicular doses in prostate intensity-modulated and volumetric-modulated arc radiation therapy at different energy levels
    Onal, Cem
    ArsIan, Gungor
    Dolek, Yemliha
    Efe, Esma
    Medical Dosimetry, 2016, 41 (04) : 310 - 314
  • [47] Cochlear Sparing for Brain Tumor Radiotherapy: A Retrospective Study Comparing Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Therapy
    Soydemir Gocer, Gulsen Pinar
    Ozer, Elif Eda
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2020, 35 (03): : 266 - 273
  • [48] Comparison of plan optimization for single and dual volumetric-modulated arc therapy versus intensity-modulated radiation therapy during post-mastectomy regional irradiation
    Zhao, Li-Rong
    Zhou, Yi-Bing
    Sun, Jian-Guo
    ONCOLOGY LETTERS, 2016, 11 (05) : 3389 - 3394
  • [49] Correlation analysis between 2D and quasi-3D gamma evaluations for both intensity-modulated radiation therapy and volumetric modulated arc therapy
    Kim, Jung-in
    Choi, Chang Heon
    Wu, Hong-Gyun
    Kim, Jin Ho
    Kim, Kyubo
    Park, Jong Min
    ONCOTARGET, 2017, 8 (03) : 5449 - 5459
  • [50] Evaluation of robustness of optimization methods in breast intensity-modulated radiation therapy using TomoTherapy
    Oki, Yuya
    Akasaka, Hiroaki
    Uehara, Kazuyuki
    Mizonobe, Kazufusa
    Sawada, Masanobu
    Nagata, Junya
    Harada, Aya
    Mayahara, Hiroshi
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (02) : 465 - 475