Evaluation of the conformity of intensity-modulated radiation therapy and volumetric modulated arc therapy using AAPM TG 119 protocol

被引:0
|
作者
Tam, Dang Thi Minh [1 ]
Ho, Phan Long [2 ,3 ,4 ]
Uy, Phan Quoc [1 ,2 ,3 ]
Hieu, Nguyen Trung [1 ]
Linh, Vo Tan [1 ]
Hoa, Nguyen Thi [1 ]
Lam, Nguyen Thi The [1 ]
Nga, Bui Thi Thuy [1 ]
Thanh, Truong Huu [1 ]
Thanh, Tran Thien [2 ,3 ]
Tao, Chau Van [2 ,3 ]
机构
[1] Ho Chi Minh Oncol Hosp, Dept Radiol Technol, Ho Chi Minh, Vietnam
[2] Univ Sci, Fac Phys & Engn Phys, Dept Nucl Phys, 227,Nguyen Van Cu St,Dist 5, Ho Chi Minh, Vietnam
[3] Vietnam Natl Univ, Ho Chi Minh, Vietnam
[4] Inst Publ Hlth Ho Chi Minh City, Ho Chi Minh, Vietnam
关键词
IMRT; VMAT; TG; 119; protocol; TrueBeam linac; Semiflex ion chamber; EPID; Quality assurance; IMRT; VERIFICATION; RADIOTHERAPY; IRRADIATION; CARCINOMA; SYSTEM; VMAT;
D O I
10.1007/s00411-024-01091-2
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The aim of this work was to evaluate the conformity of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT), and verify the accuracy of the planning and delivery system used in this work based on the AAPM TG-119 protocol. The Eclipse 13.6 treatment planning system (TPS) was used to plan the TG-119 test suite, which included four test cases: MultiTarget, Prostate, Head/Neck, and C-Shape for IMRT and VMAT techniques with 6 MV and 10 MV acceleration voltages. The results were assessed and discussed in terms of the TG-119 protocol and the results of previous studies. In addition, point dose and planar dose measurements were done using a semiflex ion chamber and an electronic portal imaging device (EPID), respectively. The planned doses of all test cases met the criteria of the TG-119 protocol, except those for the spinal cord of the C-Shape hard case. There were no significant differences between the treatment planning doses and the doses given in the TG-119 report, with p-values ranging from 0.974 to 1 (p > 0.05). Doses to the target volumes were similar in the IMRT and VMAT plans, but the organs at risk (OARs) doses were different depending on the test case. The planning results showed that IMRT is more conformal than VMAT in certain cases. For the point dose measurements, the confidence limit (CLpoint) of 0.030 and 0.021 were better than the corresponding values of 0.045 and 0.047 given in the TG-119 report for high-dose and low-dose areas, respectively. Regarding the planar dose measurements, the CLplanar value of 0.38 obtained in this work was lower than that given in the TG-119 report (12.4). It is concluded that the dosimetry measurements performed in this study showed better confidence limits than those provided in the TG 119 report. IMRT remains more conformal in certain circumstances than the more progressive VMAT. When selecting the method of delivering a dose to the patient, several factors must be considered, including the radiotherapy technique, energy, treatment site, and tumour geometry.
引用
收藏
页码:557 / 571
页数:15
相关论文
共 50 条
  • [31] Influence of multi-leaf collimator leaf transmission on head and neck intensity-modulated radiation therapy and volumetric-modulated arc therapy planning
    Sasaki, Motoharu
    Tominaga, Masahide
    Kamomae, Takeshi
    Ikushima, Hitoshi
    Kitaoka, Motonori
    Bando, Ryota
    Sakuragawa, Kanako
    Oita, Masataka
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (09) : 511 - 525
  • [32] Prognostic factor analysis of definitive radiotherapy using intensity-modulated radiation therapy and volumetric modulated arc therapy with boluses for scalp angiosarcomas
    Kashihara, Tairo
    Igaki, Hiroshi
    Ogata, Dai
    Nakayama, Hiroki
    Nakamura, Satoshi
    Okuma, Kae
    Mori, Taisuke
    Yamakawa, Kohei
    Takahashi, Akira
    Namikawa, Kenjiro
    Takahashi, Ayaka
    Takahashi, Kana
    Kaneda, Tomoya
    Inaba, Koji
    Murakami, Naoya
    Nakayama, Yuko
    Okamoto, Hiroyuki
    Yamazaki, Naoya
    Itami, Jun
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [33] Performance evaluation of gated volumetric modulated arc therapy
    Swamy, S. Thirumalai
    Radha, C. Anu
    Arun, G.
    Kathirvel, M.
    Subramanian, V.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2016, 14 (02): : 81 - 90
  • [34] Comparison of action levels for patient-specific quality assurance of intensity modulated radiation therapy and volumetric modulated arc therapy treatments
    Mancuso, Gordon M.
    Fontenot, Jonas D.
    Gibbons, John P.
    Parker, Brent C.
    MEDICAL PHYSICS, 2012, 39 (07) : 4378 - 4385
  • [35] Intensity-Modulated Radiation Therapy for Breast: Is It for Everyone?
    McCormick, Beryl
    Hunt, Margie
    SEMINARS IN RADIATION ONCOLOGY, 2011, 21 (01) : 51 - 54
  • [36] VOLUMETRIC ARC INTENSITY-MODULATED THERAPY FOR SPINE BODY RADIOTHERAPY: COMPARISON WITH STATIC INTENSITY-MODULATED TREATMENT
    Wu, Q. Jackie
    Yoo, Sua
    Kirkpatrick, John P.
    Thongphiew, Danthai
    Yin, Fang-Fang
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (05): : 1596 - 1604
  • [37] Pelvic radiation therapy with volumetric modulated arc therapy and intensity-modulated radiotherapy after renal transplant: A report of 3 cases
    Sandra Ileana, Perez Alvarez
    Prudencio Rubi, Ramos
    Francisco Javier, Lozano Ruiz
    Monserrat del Sagrario, Macias Gonzalez
    Christian Haydee, Flores Balcazar
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (04) : 548 - 555
  • [38] Evaluation of the trade-offs encountered in planning and treating locally advanced head and neck cancer: intensity-modulated radiation therapy vs dual-arc volumetric-modulated arc therapy
    Oliver, M.
    McConnell, D.
    Romani, M.
    McAllister, A.
    Pearce, A.
    Andronowski, A.
    Wang, X.
    Leszczynski, K.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1020) : 1539 - 1545
  • [39] Volumetric modulated arc therapy versus intensity-modulated proton therapy in neoadjuvant irradiation of locally advanced oesophageal cancer
    Celik, Eren
    Baus, Wolfgang
    Baues, Christian
    Schroder, Wolfgang
    Clivio, Alessandro
    Fogliata, Antonella
    Scorsetti, Marta
    Marnitz, Simone
    Cozzi, Luca
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [40] Modulated Arc Therapy for hippocampal-avoidance whole brain radiation therapy: planning comparison with intensity modulated Radiation Therapy
    Martin-Tovar, E. A.
    Badillo-Alvarado, A. H.
    Cocom-Poot, L. E.
    Gaxiola-Sosa, J. L.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (03) : 443 - 454